Functioning: 

The 

  filter  control  system  PC-400-ES  enables  time-controlled  connection  and 

disconnection of a 400V A.C. filter pump. Setting of the daytime and the individual response 
times  can  be  noted  from  the  corresponding  operating  instructions  of  the  automatic  switch 
which is enclosed. By means of the selector switch in the front cover it is possible to: 
a)  Switch on and off the functioning of the unit. 

Attention, the control system is thus not 

disconnected from the mains supply at all poles!

 

b)  to switch the unit to permanent operation or automatic operation (automatic switch) of the 

filter pump.      

Also  during  the  working  time  of  the  filter  pump,  the  heating  of  the  pool  is  regulated  by  the 
electronic  temperature  control.  During  interruptions  of  the  filtering  process,  the  heating  is 
automatically  switched  off  by  the  internal  locking  device.  The  requested  temperature  of  the 
pool  water  may  be  chosen  or  the  heating  may  be  switched  off  by  an  adjuster  on  the  front 
plate.      
Operation of the filter pump and the heating is displayed by indicator lamps in the front cover - 
controlling is therefore possible at any time. 
Connection terminals for an electronic level control 

-NR-12-TRS-2 or NR-12-TRS-3 ensure 

a  comfortable  automatic  control  of the  water  level  in  the  pool.  Additionally,  the filter  pump  is 
protected against damage which may arise due to operation of the filter unit without water.                  
Connection  terminals  for  an   

-EUROTRONIK-10  (Art.No.  3104800201)  ensure  an 

enlargement of the filter control to an automatic filter- and re-flushing control.             

Another  terminal  connection  enables  the  connection  of  additional  devices,  e.g.  dosing 
technology. The terminals D/D are potential-free and can therefore be used individually. The 
relay contact between terminals D/D is closed during the filter times; this relay contact is open 
outside  of the filter times. This  contact  can  be  used  with  a  maximum  voltage  of  230V  and  a 
maximum load of 400W (cos 

φ = 1). 

The connection terminals for the winding protection contact (WSK) enable the connection of a 
winding protection contact switch, which is integrated in the motor winding of the filter pump. If 
this contact opens, e.g. due to excessive heating of the motor winding, the filter pump and with 
it  the  heating  and  dosing  technology  are  automatically  switched  off.  As  soon  as  the  winding 
protection  contact  closes  after  the  motor  winding  has  cooled  down,  the  units  switches  on 
again  automatically.  A  manual  reset  is  not  required.  The  "WSK"  connection  terminals  carry 
230V. 

Operation of the filter pump and the heating is displayed by indicator lamps in the front cover - 
controlling is therefore possible at any time. 

The filter pump is protected against overload by an electronic motor protection (current range 
continuously adjustable up to 8A). 