background image

6

2

3

1

4

8

7

9

12

10

5

11

Tools required:

• 1/8” allen wrench (included)

• Power drill and set of drill bits

• Flat blade screwdriver (potentiometer & terminal size)

• Center punch

• Screwdriver (Phillips size 2)

• Wire stripper

• Tape ruler

• #7 drill 1/4-20 tap (metal frame install)

•  

servicing or cleaning.

•  

To reduce the risk of injury or person, use the operator only with 

Pedestrian Swing doors.

•  

This operator is for indoor use only.

Always disconnect the main power to the operator prior to 

•  

circuit from the main circuit breaker panel and must NOT be 
connected into any building lighting system that operates 
flourescent lights.

•  

Maximum door size:  48 in (1219mm) wide x 250 lb (113.4kg).

120VAC power supplied to the operator must be a dedicated 

WARNINGS

!

®

5700 

 LEO  

Power Operator

Installation and Instruction Manual

Series

ASSA ABLOY

80-9357-0008-020 (Rev 3)

Item No.

Description

1          Back plate

2          Door Closer (1601LAP or 1601BFLAP)

3          Motor Assembly (5700M)

4          Inverter (5700IN)

5          Cover (5700CVR)

6          On/Off switch

7          Circuit Breaker

8          120VAC Electrical Connections

9          Activation Inputs

10         Door Open/Closed Position Magnets

11         Optional RF Receiver

12         Power Supply -  1.1A 24V 

Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. 
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. 
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 

80-9357-0008-020 (Rev 3)

Summary of Contents for 5700 LEO series

Page 1: ...um door size 48 in 1219mm wide x 250 lb 113 4kg 120VAC power supplied to the operator must be a dedicated WARNINGS 5700 LEO Power Operator Installation and Instruction Manual Series ASSA ABLOY 80 9357...

Page 2: ...ify that the door frame is properly reinforced and is well anchored in the wall Unreinforced hollow metal frames and aluminum frames should be prepared and fitted with 1 4 20 blind rivet nuts furnishe...

Page 3: ...andicapped people ANSI A156 19 These products are designed to conform to this specification for power assist and low energy power operated doors PAS Function is designed to meet or exceed all of the r...

Page 4: ...es or for aluminum frames B Concealed Wired Units Only Two 2 7 8 22mm diameter holes for conduit for power input and for switch sensor wires NOTE On new construction these holes will generally be dril...

Page 5: ...valve and Latch Speed L valve See Fig 2 below for location of valves Turn valves clockwise to reduce speed counter clockwise to increase speed Opening Cycle Adjust Backcheck B valve as necessary for h...

Page 6: ...ine hand of door from illustration on upper right of this page Step 2 Using template above locate and prepare holes in the frame door Frame A Prepare six 6 holes for 1 4 20 machine screws or No 14 x 2...

Page 7: ...the door will take at least 3 seconds to move to a point 3 75mm from the latched position measured at the leading edge of the door Step 11 Make wiring connections using Wiring Instructions on Page bel...

Page 8: ...22 COM Common power lead Hot power lead Circuit Breaker Switch Circuit Breaker Common connection to Circuit Breaker Inverter Thread conduit fitting s into backplate as shown A second conduit fitting i...

Page 9: ...djusted POT FUNCTION DESCRIPTION OBSTR SENS Obstruction Detection on Open CW Increase CCW Decrease M DLY Motor Delay on Opening CW Increase CCW Decrease P1 Closing Speed CW Increase CCW Decrease H O T...

Page 10: ...pply 12 24 V AC DC COM NO NC Troubleshooting Jump activation input Change the setting of the ON OFF switch Flip Door Mounting Dip Switch to other direction Remove object Re time and re install arm Inc...

Page 11: ...lectromagnetic Lock 24VDC Wiring 1 2 3 4 1 2 3 4 Wall Switch Card Reader Key Switch etc Normally Open Momentary dry contacts 24VDC Electromagnetic Lock Fail Safe Operation Activating switch will cut p...

Page 12: ...Button on the receiver depending on the activation requirements if delay learn is selected adjust potentiometer to counterclockwise limit 0 second delay Red LED on receiver will flash After learn cycl...

Page 13: ...Y Group company Copyright 2015 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibi...

Page 14: ...t scale drawing Right hand door shown This template information based upon use of 5 127mm maximum width butt hinges A separate template is required for other conditions Maximum frame reveal is 6 7 8 1...

Page 15: ...ion based upon use of 5 127mm maximum width butt hinges or 3 4 19mm offset pivots A separate template will be supplied for other conditions Maximum frame reveal is 7 178mm for this application Conduit...

Page 16: ...BLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited 80 9357 0008 020 Rev 3 3000 Highway 74 East Monroe NC...

Reviews: