REMOVING THE THERMOSTAT FROM 
THE BACKPLATE

1. Insert a flat blade screwdriver or coin 1/8” into the slot located 

in the bottom center of the thermostat case and twist 1/4 turn.  
When you feel or hear a click, grasp the case from the bottom 
two corners and separate from the backplate as shown in the 
diagram at the left.  Some models require more force than 
others when separating due to the number of terminals used.

2. Swing the thermostat out from the bottom.
3. Lift the thermostat up and off the backplate.
4. Place the rectangular opening in the backplate over the 

equipment control wires protruding from the wall and, using 
the backplate as a template, mark the location of the two 
mounting holes.  

NOTE:

 If adding the wireless backplate 

(WBM-1 or WBM-WiFi), simply discard the backplate which 
came with the thermostat.  The wiring instructions for the 
equipment are identical.

5. Use the supplied anchors and screws for mounting on drywall 

or plaster; drill two 3/16” (5mm) diameter holes at the marked 
locations; use a hammer to tap the nylon anchors in flush 
to the wall surface and fasten backplate using the supplied 
screws.  (Do not over tighten!)

6. Connect the wires from your system to the thermostat 

terminals as shown in the wiring diagrams.  Carefully dress 
the wires so that any excess is pushed back into the wall 
cavity or junction box.  Ensure that the wires are flush to the 
plastic backplate.  The access hole should be sealed or 
stuffed to prevent drafts from affecting the thermostat.

BUTTON OPERATION 

THERMOSTAT LOCATION

To ensure proper operation, the thermostat should be mounted 
on an inside wall in a frequently occupied area of the space. 
In addition, its position must be at least 18” (46 cm) from any 
outside wall, and approximately 5’, (1.5 m) above the floor in a 
location with freely circulating air of an average temperature. 

Be sure to avoid the following locations:

•  Behind doors or in corners where freely circulating air is 

unavailable

•  Where direct sunlight or radiant heat from appliances might 

affect control operation

•  On an outside wall
•  Adjacent to, or in line with, conditioned air discharge grilles, 

stairwells or outside doors

•  Where its operation may be affected by steam or water pipes 

or warm air stacks in an adjacent partition, or by an unheated/
uncooled area behind the thermostat

•  Where its operation may be affected by lighting dimmers 

next to it

•  Where its operation will be affected by the supply air of an 

adjacent unit

•  Near sources of electrical interference such as arcing 

relay contact

INTRODUCTION

The RP32-NX Programmable Thermostat represents the most 
advanced solid-state, microcomputer temperature control on 
the market today.  The thermostat incorporates state-of-the-art 
technology packaged in an extremely low profile designer 
series case.  Integrated with the Net/X™ XBus communications 
port, the RP32-NX is positioned to allow either wired (XBus), 
wireless StrongMesh™ (802.15.4), or wireless WiFi (802.11) set 
up and communications.  The Ultra-Touch push-buttons are 
combined with an easy-to-read, full function liquid crystal display 
to provide the ultimate in user friendly operation of your heating 
and air conditioning equipment, including gas, electric, oil and 
heat pump controls.

STANDARD FEATURES

•  No batteries required – always remembers scheduled events 

and temperatures

•  Computerized heat anticipation and cooling drop
•  Intelligent Fuzzy Logic staging for efficient operation of 

equipment, including auxiliary heat

•  Built-in short cycle equipment protection during normal 

operation

•  Tamper proof electronic keyboard lockout with programmable 

override ranges

•  Automatic, manual and recirculation fan operation
•  Auto or manual heat/cool changeover
•  Vacation hold feature allows extended override with return day 

and time

•  Temporary schedule override with automatic schedule return
•  Selectable 12 or 24 hour clock display 

(Communication Interface only)

•  Selectable Fahrenheit or Celsius temperature display
•  Integrated XBus™ Communications for programming via 

computer, web and smart phone

Installation and Programming 

Instructions for

RP32-NX 

Residential Programmable Thermostat 

with XBus™ Communications

www.networkthermostat.com

TABLE OF CONTENTS

INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
BUTTON OPERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
THERMOSTAT LOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
REMOVING THE THERMOSTAT FROM THE BACKPLATE . . . . . 4
DESCRIPTION OF THE DIP SWITCH FUNCTIONS  . . . . . . . . . . 5
FEATURES AND SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
COVER LOCK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
REPLACING THE THERMOSTAT ON THE BACKPLATE . . . . . . . 7
BUTTON PRESS COMBINATIONS . . . . . . . . . . . . . . . . . . . . . . . 8
TEMPERATURE OVERRIDE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
VACATION OVERRIDE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9
CHANGING FAHRENHEIT (°F) TO CELSIUS (°C) . . . . . . . . . . . . 9
CHANGING 12 HOUR TIME TO 24 HOUR TIME  . . . . . . . . . . . 10
POWER FAILURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
OUTDOOR TEMPERATURE INDICATOR  . . . . . . . . . . . . . . . . . 10
PROGRAMMING THE THERMOSTAT . . . . . . . . . . . . . . . . . . . . 10
COMMUNICATIONS CONNECTION TO THE THERMOSTATS . 11
WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-20
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
SENSOR FAULTS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Mode

Vacation

Fan

Resume

Press to Select

Heat/Cool/Auto/Off.

The word is displayed

for 5 seconds. 

Press to Raise Setpoint or

increase numeric values.

Press to Resume

Normal Schedules.

Press to Set a 

Vacation Override.

LED2 (YELLOW)

Press to Lower Setpoint or

decrease numeric values.

Press for Selection of

Fan Auto, Fan On, or

Recirculation Fan.

LED3 (RED)

LED1 (GREEN)

TM

2

3

4

1

Summary of Contents for RP32-NX

Page 1: ...f electrical interference such as arcing relay contact INTRODUCTION The RP32 NX Programmable Thermostat represents the most advanced solid state microcomputer temperature control on the market today The thermostat incorporates state of the art technology packaged in an extremely low profile designer series case Integrated with the Net X XBus communications port the RP32 NX is positioned to allow e...

Page 2: ...ility company Add On Dual Fuel Heat Pump Control If needed the thermostat will perform the function of a fossil fuel kit When in this mode the thermostat will turn off the compressor with a call for AUX heat When Switch 1 and Switch 5 are in the ON position the thermostat allows the compressor and the AUX heat to be on simultaneously Random Restart After a power failure the thermostat will delay t...

Page 3: ...mperature This temperature will be maintained for the pre programmed amount of time To cancel simply press the RESUME button Temporary Override with Keyboard Locked 15 minutes to 8 hours You may change the temperature setting temporarily at any time without affecting the program even though the keypad is locked Press the UP or DOWN buttons The display will show the temperature for the first event ...

Page 4: ...TES ON OFF LOCKED DIP1 OFF GAS HEAT DIP1 ON HP DUAL FUEL 2 STAGE CONTROL 5F OVERRIDE RANGE NOT USED KEEP OFF EQUIPMENT WIRING DIAGRAM RP32 NX 2 Stage Gas Furnace Air Conditioning HVAC CONNECTIONS Line Voltage 24 Vac Transformer COOL 1 FAN 24 VAC G Note 1 A Yellow R 24V Jumper is on thermostat circuit board and must be removed if thermostat is to be powered over the XBUS network HEAT 1 W1 Y1 COMMON...

Page 5: ... OFF LOCKED DIP1 OFF GAS HEAT DIP1 ON HP DUAL FUEL 2 STAGE CONTROL 5F OVERRIDE RANGE NOT USED KEEP OFF EQUIPMENT WIRING DIAGRAM RP32 NX 1 Stage Heat Pump Standard Operation HVAC CONNECTIONS COMPRESSOR 1 FAN 24 VAC G O Note 1 A Yellow R 24V Jumper is on thermostat circuit board and must be removed if thermostat is to be powered over the XBUS network AUXILIARY HEAT W1 REVERSING VALVE B Y1 COMMON 1 5...

Page 6: ... period of one year from the date of purchase with proof of purchase Warranty Limitations This warranty begins on the date of purchase Warranty is Void if The date code is defaced or removed The product has a defect or damage due to product alteration connection to an improper electrical supply shipping and handling accident fire flood lightning or other conditions beyond the control of the manufa...

Reviews: