background image

 

 

  

Hao-Hao Intelligent Pregnant Preparation Instrument

 TM

 

 

Product Name: Comper Smart Fertility Tracker 

Product Model: BBTX

 

 

 

COMPER 

TM

 

Summary of Contents for BBTX

Page 1: ...Hao Hao Intelligent Pregnant Preparation Instrument TM Product Name Comper Smart Fertility Tracker Product Model BBTX COMPER TM ...

Page 2: ......

Page 3: ...uctions for use Disinfection function Charging function Prompt function Voice Prompt Cleaning and maintenance Problems and Troubleshooting Storage and Shipping Condition Basic Parameters and Specifications The Registration Certificate Number and Production License Number Service Agencies and Information ...

Page 4: ...ned basal body temperature monitoring device for women Body temperature can be accurately measured by electronic sensors satisfying the demand of daily basal body temperature monitoring of women and is satisfied the requirement of daily monitoring by laypersons nursing staff and care givers in obstetrical department in hospital clinics and pregnant women at home Application scope monitor the ovula...

Page 5: ...on certificate Composition 1 2 4 5 6 Parts list 1 One pregnant preparation instrument thermometer 2 One disinfection charging box 3 One USB charging cable 4 One manual 5 One qualification certificate 6 Hao Hao Health APP 3 ...

Page 6: ...ant preparation instrument indicator lamp 2 Heat probe 3 Contact based charging interface 4 The anti skid particles 5 Disinfection charging box interface 6 Charging indicator 7 Contact based charging connector 8 UV disinfection lamp 7 6 5 8 ...

Page 7: ...ibition It represents absolutely not allowed There is death or injury risk caused by operation that is out of the performance of the product or appropriate Warning Represent matters that require special attention Represent matters that require special attention which may cause death or serious disease even in normal operation Caution Represent general considerations in using If misused it may caus...

Page 8: ...w the guidance of a doctor Self diagnosis may cause possibility of deterioration of diseases This product is an oral dedicated thermometer and is not allowed to use in any parts other than the mouth especially the parts of the ear to measure body temperature It is unable to correctly measure the temperature and there is possibility of causing harm to the ears Do not share this product with others ...

Page 9: ... box Incorrect placement may cause possibility of damages to product Do not use the product closely to strong electromagnetic fields electromagnetic wave and magnetic environment There is possibility of measurement errors or damage to the product Avoid severe shock falling from the height or stomping after putting into the disinfection box There is possibility of causing damage to the product Do n...

Page 10: ... is possibility of causing serious body injury measurement error and damages to the product Do not take out the magnet from disinfection charging box Magnet damage may cause possibility of damage to product At the end of product life please deal with the product according to the relevant local environmental protection laws and regulations Scope of application and contraindications Contraindication...

Page 11: ...used with APP 1 Download by scanning QR code 2 Download from the application store search Hao Hao Health Note Piggyback Bluetooth 4 0 and above module IOS7 0 and above operating system Piggyback Bluetooth 4 0 and above module Android 4 3 and above operating system ...

Page 12: ......

Page 13: ... in first use 1 Open the Bluetooth of mobile phone 2 Open the Hao Hao Health APP and create an account 3 Select device of Hao Hao Health Intelligent Pregnant Preparation Instrument and conduct subsequent operations according to APP tips For questions please contact customer service ...

Page 14: ...ation instrument back into disinfection charging box after measurement pregnant preparation instrument will automatically shut down Please connect with the power and close the disinfection charging box the function of disinfection will turns on automatically ...

Page 15: ...11 Charging Function 1 Put the pregnant preparation instrument in the disinfection charging box ...

Page 16: ...12 2 Insert the USB charging cable into the charging interface of disinfection charging box ...

Page 17: ...13 3 Lamp displays orange light when it is in charging Lamp displays white light when charging is completed ...

Page 18: ......

Page 19: ...light one time of beep The main body turns on Flicker white light Successful connection of Blueteeth Long white light three times of beep No measurement temperature is too low or too high or abnormal measurement Light turned down Electric quantity exhaustion Orange light Period of easy pregnancy Blue light Period of non easy pregnancy White light No measurement results ...

Page 20: ...16 Voice Prompt 1 x 1 One time of beep after measurement represents completion of measurement 3 x 2 Three times of beep after measurement represent abnormal measurement temperature ...

Page 21: ...power put the instrument into the disinfection charging box and automatic disinfection of ultraviolet ray will begin and last about 5 minutes Please comply with the following precautions to avoid breakdown or failure Do not remove dirt by using volatile agents diluent or gasoline etc The disinfection charging box is not waterproof please avoid water flowing into the box Do not immerse the heat det...

Page 22: ......

Page 23: ...ue to incorrect measurement position The measured value is too low due to open mouth measurement Artificial interruption of the measurement The measured value is too high due to a long time placement in hot environment No flicker of white light after startup Bluetooth is not connected with the phone No indicator lamp is turned on after taking out of the disinfection charging box Electric quantity ...

Page 24: ...ent position Please close the lips during the measurement and do not breathe by mouth Please conduct measurement according to correct instructions Please use the product in the environment of 5 C to 40 C Please check whether the Hao Hao Health APP is in operation Please check whether your phone Bluetooth is turned on in operation Please charge ...

Page 25: ...ment High temperature direct sunlight dusty environment or salt environment Environment with chemicals or corrosive gas Storage environment Temperature 10 C to 40 C Humidity 85 Ventilated room without corrosive gases Transportation environment Temperature 40 C to 55 C Humidity 90 RH Atmospheric pressure 50 to 101 3 kPa Method air sea rail transport or coach transport ...

Page 26: ... replaced regularly Category of product Electric shock protection type internal power supply Electric shock protection type BF product Level of anti liquid IPX6 main body of pregnant preparation instrument Anti level liquid feed IPX6 prepared pregnant instrument body The degree of safety of combustible gas not suitable for using in environment with flammable gas Operating mode Single measurement S...

Page 27: ...e 70 to 101 3 kPa Product performance Sensor Rapid response thermistor Measurement High speed precision Found Measuring range 35 00 C to 42 00 C Accuracy 35 00 C to 39 00 C 0 05 C 39 1 C to 42 0 C 0 1 C Measurement accuracy 0 01 C displayed on the Hao Hao Health APP Life 4 years ...

Page 28: ...duction license number Service Agencies and Information Production company name Comper Beijing Technology Co Ltd Manufacturer address Floor 3 Unit 712 713 Building 1 No 3 Yongchang North Road Economic and Technological Development Zone Beijing Manufacturer Tel 86 01057480968 Manual version BT M 01 15 Rev 02 Date of formulation revision September 2015 ...

Page 29: ... increasedor decreased excerpted reproduced alteredor imitated without the prior written consent of the Company For the content of this Manual the Company is not responsible for any explicit or implied warranty or guarantee liability The content change caused by product improvements and technology updates could occur at any time without prior notice The power of interpretation is vested by the Com...

Page 30: ...eption which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an ex...