background image

SRL-6057-S LED Par Lamp

USER MANUAL

        

Table of Content

Part I General Information--------------------------------------------------------------------------------3

1.1 Introduction----------------------------------------------------------------------------------------3

Summary of Contents for SRL-6057-S

Page 1: ...SRL 6057 S LED Par Lamp USER MANUAL Table of Content Part I General Information 3 1 1 Introduction 3 ...

Page 2: ...hart 13 Part I General Information 1 1 Introduction You have purchased the SRL 6057 S High Power LED Par Lamp series product To assure reliable performance please read the instructions in this manual thoroughly and carefully before operating 1 2 Safety Information The following definitions of identifying the severity of the hazards associated with the products are used DANGER Imminently hazardous ...

Page 3: ...ts inside Do not attempt to open the fixture Note The instructions and precautions in this user manual are or maybe not necessarily applicable or relevant to all applications Neo Neon cannot anticipate all possible applications or use of this product Owner User Responsibilities The contractor installer purchaser owner and user is solely responsible to install maintain and operate this product in s...

Page 4: ...xture 1 5 Features Low power consumption Maintenance free operation 100 000 hours rated LED lifespan 36 PCS of high bright LED generates 16 7 million additive RGB colors DMX Auto Sound Active Master Slave stand alone 8 auto programs accessed via DMX controller or stand alone Sound activated via built in microphone of adjustable sensitivity Brilliant light output Part II Installation and Operation ...

Page 5: ...SRL 6057 S Par Lamp Operating Panel PART II Installation and Operation continued 2 2 AC Power The fixture s mains lead may require a grounding type plug connector that fits your 5 ...

Page 6: ...oller manufactures as a communication between fixtures and controllers A DMX controller sends out DMX instructions that travel through the DMX chain as a serial data to the fixtures via XLR cables DMX is a common language allowing all modules of different manufactures to be linked together and operate from a single controller as long as all modules and the controller are DMX compatible B DMX Cable...

Page 7: ... unit features an easy to understand LED digital display to shows what modes or status it is working in For example if the display shows Axxx it means that the machine is working in DMX mode Following table detailed the information LED displays Meaning Axxx DMX mode Pxxx Auto Master Px x x Sound active Master Sxxx Slave mode Dipswitch 1 address equals to 1 Dipswitch 2 address equals to 2 Dipswitch...

Page 8: ... 0 0 0 1 Sound Program 2 0 1 0 0 1 Sound Program 3 0 0 1 0 1 Sound Program 4 0 1 1 0 1 Sound Program 5 0 0 0 1 1 Sound Program 6 0 1 0 1 1 Sound Program 7 0 0 1 1 1 Sound Program 8 0 1 1 1 1 DMX 1XX XXXX X The Slave of Master Slave 1 PART II Installation and Operation continued A DMX mode To have the fixture working in DMX mode please toggle on the dipswitch 1 of Group1 as illustrates in below fig...

Page 9: ...est as slave mode By switching the dipswitch 1of Group 2 off you set this fixture to master mode By switching the dipswitch 1 of Group 2 on you set this fixture to slave mode as the way you set it to DMX mode PART II Installation and Operation continued C Select auto programs To select auto programs turn the dipswitch 1 of the 2nd group dipswitches off and dipswitch 8 off Auto programs are then se...

Page 10: ... The path of the program is the same as Auto Program Mode except that it is triggered by sound PART II Installation and Operation Part III Maintenance and Cleaning Please refer to the following points during the normal inspection Warning Make certain all screws and fasteners are securely tightened at all times Loosened screws may cause unexpected damage or injury Warning Do not use this product if...

Page 11: ... continued 3 3 Troubleshooting Trouble Cause Remedy Fixtures do not responds No power supply Check the mains power switch and the cables Fuse burned Disconnect the power and replace the fuse with the same specification If the fuse is burned again the problem should be cause by the circuit Please consult the local service agency The reset is normal But the fixtures do not responds or act abnormally...

Page 12: ... 295 327 359 391 423 455 487 0 0 0 1 0 8 40 72 104 136 168 200 232 264 296 328 360 392 424 456 488 1 0 0 1 0 9 41 73 105 137 169 201 233 265 297 329 361 393 425 457 489 0 1 0 1 0 10 42 74 106 138 170 202 234 266 298 330 362 394 426 458 490 1 1 0 1 0 11 43 75 107 139 171 203 235 267 299 331 363 395 427 459 491 0 0 1 1 0 12 44 76 108 140 172 204 236 268 300 332 364 396 428 460 492 1 0 1 1 0 13 45 77...

Page 13: ...440 472 504 25 57 89 121 153 185 217 249 281 313 345 377 409 441 473 505 26 58 90 122 154 186 218 250 282 314 346 378 410 442 474 506 27 59 91 123 155 187 219 251 283 315 347 379 411 443 475 507 28 60 92 124 156 188 220 252 284 316 348 380 412 444 476 508 29 61 93 125 157 189 221 253 285 317 349 381 413 445 477 509 30 62 94 126 158 190 222 254 286 318 350 382 414 446 478 510 1 1 1 1 1 31 63 95 127...

Reviews: