Instruction Sheet

Subject: BIC Tune Up

SCOPE: MULTIPLEX BIC UNITS MA-8-2, MA-8-2BF, MA-8-2AF

 

1 of 9

 

Document Number: 020009017  May 12, 2022

MULTIPLEX 

645 PARK EAST BLVD SUITE 5, NEW ALBANY, IN 47150

844-724-CARE

WWW.MULTIPLEXBEVERAGE.COM

Refreshing the Experience

TOOLS REQUIRED

•  Safety Gloves (cut resistant)
•  Oetiker Pliers (PN 00681815)
•  Needle Nose Pliers
•  Screw Drivers, Phillips & Flat Head 
•  3/8” or ¼” Drive Socket Set (3/8” and 5/16”)
•  Standard Open End Wrench Set
•  Soft Bristle Brush
•  Wet/Dry Shop Vacuum
•  Digital Scale (weighs in ounces to once decimal place)

PARTS REQUIRED

•  Food Grade Lubricant
•  5 - 6 ft (1.8m) ¼” I.D. X 3/8 “ O.D. clear tubing 
•  TUNE UP KIT 020009016 (contents listed below)

QTY

DESCRIPTION

PART NUMBER

9

Valve, Dispense Outlet, LMS

1706172

9

15.7 Oetiker Clamp

15.7-706R

2

O-ring, replacement

MCP00262

1

Gasket Ice Shaver

3434865

1

Drive belt, Shaver Vitamix 1617

VMP00123

2

Cup Grate O-rings

3547901

1

Instructions Tune Up ENG

020009017

1

Instructions Tune Up French

020009047

1

SHAVER BLADE KIT

VMP00125

RECOMMENDED TRUCK STOCK LIST FOR TUNE UP

QTY

DESCRIPTION

PART NUMBER

1

SWITCH REED RINSE AREA MOD

2160033

1

SWITCH REED RINSE AREA - GRAY

2162748

5

FUSE, 5A, MIXER BOARD

2193015

1

SWITCH, SNAP ACTION, MINI - BLEN HM

2194807

1

BOARD, SRB ,BIC, GEN2

2195346

2

CONTROL BLENDER BIC HSM

2195363

1

CONTROL, 7 IN UI, BIC

000-BIC-01F9-S

1

RELAY, 24DC COIL, DPDT

2196069

2

FUSE, 4A, DC HARNESS

2198785

1

PUMP, FLOJET, NSF, NO ASO

3239675

1

MIXER MTR, 6MM, 120V/50-60, GEN3 SW

3239822

2

ASSEMBLY, LOWER BLENDER, 6MM, GEN3

3239825

1

SOLENOID VALVE REPAIR KIT

020005547

1

VALVE, S.S. SLND, WATER, 1/4"

000-BIC-01B5-S

1

SAFETY SWITCH/RECTIFIER ASSEM- 120V

VMP00113

1

SHAVER BELT

VMP00123

1

SHAVER BLADE KIT

VMP00125

1

SENSOR, HALL EFFECT

VMP00175

1

SHAVER MTR W/PULLEY / MAGNET 120V

VMP00172

3

MOTOR ISOLATION MOUNT

9324159

1

PUSH ROD

VMP00134

3

CUP ALIGNMENT RING INSERT

1708685

1

GASKET, ICE SHAVER

3434865

NOTE: Additional non-warranty parts used need to be 

invoiced on a separate invoice to the site. Manager or 

Operator must approve additional repairs.
NOTE: All right and left references are based off of standing 

in front of the unit.

,

CAUTION

Ice shaver blade is sharp on both edges.  Wear cut resistant gloves 

when handling.

n

Warning

Blender shaft contains sharp blades.  

Wear cut resistant 

gloves when handling. 

Do NOT touch the blades.

Summary of Contents for BIC MA-8-2

Page 1: ...IPTION PART NUMBER 1 SWITCH REED RINSE AREA MOD 2160033 1 SWITCH REED RINSE AREA GRAY 2162748 5 FUSE 5A MIXER BOARD 2193015 1 SWITCH SNAP ACTION MINI BLEN HM 2194807 1 BOARD SRB BIC GEN2 2195346 2 CONTROL BLENDER BIC HSM 2195363 1 CONTROL 7 IN UI BIC 000 BIC 01F9 S 1 RELAY 24DC COIL DPDT 2196069 2 FUSE 4A DC HARNESS 2198785 1 PUMP FLOJET NSF NO ASO 3239675 1 MIXER MTR 6MM 120V 50 60 GEN3 SW 323982...

Page 2: ...rewdriver or pair of needle nose pliers remove the O rings from each blender grate and discard 7 Replace with new O rings over the tip on both grates 8 Wash rinse and sanitize the blender and dispense grates 9 Prepare a five 5 gallon bucket with luke warm tap water no hotter than 105 F 40 5 C and cleaning solution Clean all eight 8 product fittings and connect the cleaning manifold 10 Position the...

Page 3: ...ea and the pushing up of the tubing inside of the cabinet until the top of the dispensing plate is easily accessible 17 Using a Phillips head screw driver remove the two 2 screws from the metal mounting plate that secures a block of three 3 LMS valves to the dispensing valve mounting plate NOTE The tubing is numbered and will need to be returned to the same position within the dispensing mounting ...

Page 4: ... using caution not to damage the micro switch push rod Use caution not to lose any of the three 3 ice bin grommets attached to the base of the ice bin bowl 26 Wash rinse and sanitize the condensate bowl 27 Carefully pour beverage drain cleaner down the ice condensate bowl drain opening 28 Remove the two 2 screws that secure the shaver blade and shims to the ice bin and ice chute cartridge 29 Insta...

Page 5: ... Once the shaver belt is replaced the motor will be returned or very near this same position when tight 38 Locate the four 4 hex head bolts that secure the shaver motor to the motor mounting bracket A Completely remove one of the bolts that secure the Hall Effect sensor mounting bracket to the motor mounting bracket Loosen the remaining three 3 hex head bolts B Swing the Hall Effect mounting brack...

Page 6: ...and CO2 supply lines and pressure observe for any leaks 54 Power the unit ON using the ON OFF switch located on the upper left side of the unit next to the USB port 55 Connect drain and plug in unit to outlet 56 Verify the water and CO2 pressure regulators are set to 35 psi dynamic and adjust if necessary A The regulators are located on the upper left side of the unit NOTE To achieve a dynamic pre...

Page 7: ...lect the Configure Slots Icon Select Slot Flavor Select the slot requiring reassignment Select Unassign Flavor and then select the GREEN Check Select the newly Unassigned Slot and select the correct flavor assignment Select the Return Arrow three 3 times to return to the main easyToUCH screen Select product Inventory Icon Select the reassigned flavor and follow the steps for replacing a product ba...

Page 8: ...ds must be entered to reset the yearly maintenance reminder even though the shafts have NOT been changed Select the MANAGER MENU Select A for the password Select the GREEN check Select the Down Arrow and select SERVICE Select A for the password Select the GREEN check Arrow DOWN and select PLANNED MAINTENANCE Select MIXER MAINTENANCE PERFORMED A 4 0 2 and before Enter SILENCE for password Select th...

Page 9: ...ge5 ReplacetheCO2andWatersupplylineO rings Step43 44onpage6 Cleanthecondensercoil Step45page6 Cleanthecondensatepan Step46page6 Cleanthecondensatedrainline Step47page6 Pourhotwaterdowndrainopeningsoftheicebin rightblendchamber dispense area andleftblendchamber Step49page6 Workthedrainsbyhandsqueezingoutanybuildup Step51 52onpage6 Connectwater CO2 drain andpowercord Step55page6 Reardrainlineconnect...