background image

 

states a hazard 

may cause serious injury or 
death if precautions are not 
followed.

START

–––––––

STOP

Digital 30-Minute Timer

Electronic Interval Timer for MrSteam 
CU Commercial Steambaths
Installation and Operating Manual

mr

.

steam

®

 

30-MInUTE TIMEr

_______________________________________________________________________________________________

99216DIG

IMporTanT noTe:

 As you follow these instructions, you will notice 

warning and caution symbols. This information is important for the safe 
and efficient installation and operation of this generator. These are types 
of potential hazards that may occur during this installation and operation:

FuncTIonalITy oF The TIMeswITch

The countdown timer uses a relay to switch the steam 
solenoid on. During the preset running time, the relay 
energizes and activates the connected steam solenoid 
by closing a circuit. After the time has elapsed, the 
relay deenergizes and deactivates the connected steam 
solenoid by opening the circuit again. THE TIMEr MAY 
OnLY BE OPErATED AFTEr InSTALLATIOn In A 
PrOTECTIVE HOUSInG. A large 3-digit LCD display is 
provided for monitoring the countdown of the timer. 

BeFore use

Before installing and using this timer, it is absolutely nec-
essary that you read this operating manual thoroughly.

saFeTy InsTrucTIons

This timer may only be installed by a qualified, licensed  

electrician and must be installed in accordance with 

national and local codes.

 

shock hazarD!

 Install the timer per 

these instructions before connecting to the main supply. 

never touch live contacts or components.

 

 Protection from contact with the line volt-

age components must be achieved by proper installa-

tion in a 4 x 4 junction box. When installing the timer, 

ensure the fastening sliders prevent the timer from being 

removed.

 

DO nOT install the timer in a wet or damp 

location.

 

DO nOT install the timer inside the steam 

room.

1. InsTallInG The TIMer

DIP SWITCHES SETTInG

Figure 1 shows the default setting for the timer. 

 

The timer is factory set to run for 30 minute

s.

 

signals a 

situation where minor injury or 
product damage may occur if 
you do not follow instructions.

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

Maximum run time can be set at 15, 30 or 60 

minutes. Use switches 3 and 4 to set run time:

run  

Switch  Switch

Time 

 3 

4

15 min.  OFF 

OFF

30 min.  OFF 

On

60 min.  On 

OFF

Figure 1: Default Settings

  cauTIon

!

warnInG

!

warnInG

!

warnInG

!

warnInG

!

warnInG

!

warnInG

!

PUr 100383   rEV  5/19

mr

.

steam

®

Sussman-Automatic Corp.

® 

 [email protected] www.mrsteam.com

43-20 34th Street, Long Island City, NY 11101  718-937-4500   •  9410 S. La Cienega Blvd., Inglewood CA 90301 310-216-6565