background image

THANK YOU!

You have just purchased a quality Lubricator from Master Pneumatic.

With care in its installation and maintenance, you can expect it to have a long and economical service life.

Before you go any further, please take a few minutes to look over this information,

then save it for future reference and for the useful service information it contains.

350 Lubricator 

Installation and Maintenance

MASTER PNEUMATIC, INC.

6701 -18 Mile Rd

. | 

Sterling Heights, MI 48314  |  Phone: (586) 254-1000  |  Fax: (586) 254-6055  |  Email: [email protected]

STU-3026

MJF 10-24-13

(ECN 4904)

Installation & Operation Procedures

NOTE:

 

Read Warning Stuffer STU-A019 included in box with product before proceeding.

INSTALLATION:

1.  Depressurize and lockout air pressure.
2.  Upstream pipes must be free of excessive dirt and liquids.
3.  Install the Lubricator as near as possible to the device it is to serve.
4.  Install the Lubricator so that air flows in direction of arrow on Lubricator Cap (#3).
5.  To insure a prompt feeding of lubricant, install the Lubricator parallel to the device being lubricated.
6.  Lubricator must be installed vertically with Bowl at the bottom.
7.  Lubricator should be installed downstream of any Filters or Regulators in the airline.  
8.    Multiple lubrication points from a single Lubricator are not recommended.
9.  If installing using modular clamp connections A118-105 or A118-105M, torque screws 30-40 in-lbs.

OPERATION:

1.  To fill Lubricator with oil, depressurize and lockout air pressure. Either remove Fill Plug (#10) or Bowl Assembly: Remove Plastic 

Bowl Assembly (#7 Section view 2) by turning Shatterguard (#6 Section View 2) counter-clockwise; Remove Metal Bowl Assembly 

(#7 Section View 1) by turning counter-clockwise. Add lubricant. Use Light Spindle Oil 60-120 SUS at 100F. Do not use compound 

oils containing graphites, synthetic oil, soap fillers, etc.

2.  Replace Fill Plug (#10) and Bowl Assembly (#7 Section View 1 or #6 & #7 Section View 2).  
3.  Turn on air pressure.
4.  Adjust the oil feed rate by turning Adjusting Knob (#1) clockwise for less oil, counter-clockwise to increase oil delivery.
5.  The Cartridge (#2) sight dome is used to monitor oil feed rate (drops/min).                            
6.  Removal of Adjusting Knob (#1) will make Lubricator tamper resistant.

TO CLEAN OR REPAIR:

1.  Depressurize and lockout air pressure.
2.  If needed, the Fill Plug (#10) can be removed by turning counter-clockwise and cleaned with soap and water.
3.  Remove Plastic Bowl Assembly (#7 Section view 2) by turning Shatterguard (#6 Section View 2) counter-clockwise. 
 

  

Remove Metal Bowl Assembly (#7 Section View 1) by turning counter-clockwise.

3.  Both the Plastic Bowl Assembly(#7 Section view 2) and the Metal Bowl Assembly (#7 Section View 1) can be cleaned with soap and 

  

water.

4.  If needed, the Cartridge Assembly (#2) can be removed and replaced. 
 

  

Pull off Adjusting Knob (#1). Remove both screws from Lubricator Cap (#3) by turning counter-clockwise. Remove Lubricator 

 

Cap (#3) and Cartridge Assembly (#2). Lubricate outside surface of rubber boot on new Cartridge Assembly with Lithium 

 

grease, insert into head (#4). Hand start screws. This will ensure the screws use original threads. Torque screws 15-20 in-lbs.

5.  When re-assembling, be sure all o-rings are correctly located. Lubricate o-rings with lithium grease. Torque Fill Plug (#10) hand tight. 

  

Torque Plastic Bowl Assembly (#6 & #7 Section view 2) or Metal Bowl Assembly (#7 Section view 1) to 75-125 in-lb, and tab 

  

must be within notch as shown in Fig 1 and 2. 

6.  If the Lubricator cannot be repaired by cleaning with soap and water the parts should be replaced.
7.     Replace Plastic Bowls with Metal if any signs of crazing or cracking are observed.

    

    SAMPLE PRODUCT NUMBERS:

   L350D-2, -3, -4
   BL350D-2, -3, -4
   L350DH-2, -3, -4
   BL350DH-2, -3, -4

Summary of Contents for L350D-2

Page 1: ...indle Oil 60 120 SUS at 100F Do not use compound oils containing graphites synthetic oil soap fillers etc 2 Replace Fill Plug 10 and Bowl Assembly 7 Section View 1 or 6 7 Section View 2 3 Turn on air pressure 4 Adjust the oil feed rate by turning Adjusting Knob 1 clockwise for less oil counter clockwise to increase oil delivery 5 The Cartridge 2 sight dome is used to monitor oil feed rate drops mi...

Page 2: ...asterpneumatic com STU 3026 MJF 10 24 13 ECN 4904 Section View 1 Metal Bowl KEY DESCRIPTION 1 Adjusting Knob 2 Cartridge Assembly sight dome adjusting needle spacer plate flow restrictor cartridge ball retainer lever etc 3 Lubricator Cap 4 Lubricator Head 5 O Ring 7 Metal Bowl 8 Feed Tube 9 Draincock 10 Fill Plug 1 2 3 4 5 7 8 9 FLOW 10 NOTCH TAB FIG 1 ...

Page 3: ...pneumatic com STU 3026 MJF 10 24 13 ECN 4904 Section View 2 Plastic Bowl KEY DESCRIPTION 1 Adjusting Knob 2 Cartridge Assembly sight dome adjusting needle spacer plate flow restrictor cartridge ball retainer lever etc 3 Lubricator Cap 4 Lubricator Head 5 O Ring 6 Shatterguard 7 Plastic LDC Bowl 8 Feed Tube 10 Fill Plug 1 2 3 4 5 6 7 8 FLOW 10 NOTCH TAB FIG 2 ...

Page 4: ...hatterguard and O ring ABL125 03 Metal Lubricator Bowl Assembly Bowl Drain Cock Sight Glass Sight Housing O Ring Screws ABL125 03H Extended Lubricator Metal Bowl Assembly Bowl Drain Cock Sight Glass Sight Housing O Ring Screws Mounting Brackets A118 103 Modular Bracket and Screw for adding bracket to existing connecting clamps A118 105M Modular Connections and Bracket Kit Modular connecting clamps...

Reviews: