manualshive.com logo in svg
background image

 

 
 
 
             

 

 
 
 
 
 
 
 
 
 
 

 
 
 
 

 

 

 

 
 

 

 

 
 
 
 
 
 
 
 
 
    
 

 
 
 
 
 
 
 
 
 
 

      

 

 

 
 
 

 

D0910-7010 

 

 

 

Microframe Corporation 

604 South 12th Street 

Broken Arrow, OK 74012 

 

Local: 918-258-4839 

Toll Free: 800-635-3811 

Website: www.microframecorp.com 

E-mail: [email protected] 

 
 

 
 

 

 
 
 

                                          SERIES 900 

INSTALLATION and SPECIFICATION GUIDE 

 

Manual No. D0910-7010 

             Revision Date: 09/2013 

          Control: 1.6 

*D0910-7010* 

 

Содержание 910

Страница 1: ... Street Broken Arrow OK 74012 Local 918 258 4839 Toll Free 800 635 3811 Website www microframecorp com E mail support microframecorp com SERIES 900 INSTALLATION and SPECIFICATION GUIDE Manual No D0910 7010 Revision Date 09 2013 Control 1 6 D0910 7010 ...

Страница 2: ...ust use plenum rated cable The cable supplied from Microframe is rated CL2 and is approved for indoor installation everywhere except plenum areas Life Support Policy Microframe s products are not authorized for use as components in life support devices or systems without the express written approval of the President of Microframe Corporation As used herein 1 Life support devices or systems are def...

Страница 3: ...pecificationGuide Table of Contents Series 900 System Overview and Features 4 System Installation Instructions 5 Maximum Cable Wire Length Chart 6 How to Connect Multiple Keypads to a Display 7 How to Connect a Display to a Keypad 8 Keypad Operation 9 Keypad Options 10 Visual Pager Display Operation 11 Error Codes and Troubleshooting Chart 12 ...

Страница 4: ...e Rollover Time Automatic Delete and Manual Advance Once a number is entered into the Keypad the number is sent immediately to the Visual Pager Display The keypad will store up to 32 numbers and display them sequentially until the operator deletes them In 4 digit mode the keypad will show numbers from 0 to 9999 This mode is compatible with Model 920 930 and 940 displays In 6 digit mode the keypad ...

Страница 5: ...ounted at eye level However it may also be placed on a desk Multiple keypads may be used on the same system and will automatically communicate with each other when wired together KEYPAD CONNECTION Unplug the keypad before continuing Slide off the back cover of the keypad and connect the 2 conductor wire Connect the black wire to GND and the red wire to SIG There are two terminals for both GND and ...

Страница 6: ...ly use 16 AWG wire from the keypad You can now install four Model 960 6 digit displays up to 1 200 feet from the keypad The TOTAL CABLE LENGTH sum of length of all cables in the system should not exceed 10 000 feet Maximum Cable Wire Distance in Feet Model 920 Model 930 Model 940 Model 960 Number of Displays 18 AWG 16 AWG 18 AWG 16 AWG 18 AWG 16 AWG 18 AWG 16 AWG 1 2000 2000 2000 2000 2000 2000 20...

Страница 7: ...ELETE when the number is being displa yed 2 Ready123456 115 TO 24 VAC WALL MOUNTED TRANSFORMER Model 906 Model 910 K eypad ENTER 0 DELETE 1 3 4 5 6 7 8 9 Visual P ager Series 900 To ENTER a paging n umber type its digits press DELETE if an error is made Then press ENTER A Blinking light indicates a n umber is being entered To DELETE a paging n umber press DELETE when the number is being displa yed...

Страница 8: ...Y AUX AUX AUX AUX NEX T DISPL AY ORKEY PAD STEP 1 Remove slide on cover from back of keypad STEP 2 Remove 1 5 of gray jacket from wire and separate the internal wires Strip 1 4 of insulation from each wire and pre form as shown STEP 3 Insert black wire into one of the GND terminals Insert red wire into one of the SIG terminals Tighten terminal screws STEP 4 IF REQUIRED If a second set of wires are...

Страница 9: ...deleted DELETE MODE To delete a number press DELETE twice when that number appears on the keypad display The next available number will be displayed immediately You may also delete a number by pressing DELETE typing the number and pressing DELETE again If you make an error while deleting a number press ENTER MULTIPLE OUTPUTS The keypad will power multiple Visual Pager displays Please see the Maxim...

Страница 10: ...ff On Default 1 The audible feedback sound can be enabled or disabled 14 Chime 0 0 9 9 Seconds Default 0 3 Sets the Visual Pager display chime duration Not all displays follow this option 19 Factory Reset 0 1 No Yes Resets all options to factory defaults 21 MastSlave 0 2 Auto Master Slave Default 0 This controls the master slave arbitration on a system There should only be one master on a system A...

Страница 11: ...to 6 digit numbers Compatible with Model 960 Displays HYMNBOARD MODE If the user would like to use the keypad to show hymn numbers in a song service the following steps should be taken 1 Program the Rollover Time 1 1 to 0 2 Program the Sort Option 2 3 to 0 3 Program the DeleteKey Option to 2 After these options have been programmed enter the hymn numbers in the order in which they will be displaye...

Страница 12: ... Keypad cannot remember settings Keypad is damaged Return for service Keypad displays CommErr Communication error Verify programming to make sure only one keypad is a master Check wiring between keypads Check for strong interference next to signal cable Keypad works but does not light up or has erratic numbers Poor signal connection to display Does the keypad work when connected to the display wit...

Отзывы: