background image

Simplifying IoT from edge to enterprise

January 31, 2019

Revision 5.0

MACH-3

 

Installation and 
Configuration Manual

Summary of Contents for MACH-3

Page 1: ...Simplifying IoT from edge to enterprise January 31 2019 Revision 5 0 MACH 3 Installation and Configuration Manual...

Page 2: ...duct CAUTION A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem WARNING A WARNING indicates a potential for property damage personal injury...

Page 3: ...ON INSTRUCTIONS 5 2 1 1 Installation Personnel 5 2 1 2 Installation Location 5 2 1 3 External Antenna 5 2 2 GATEWAY MOUNTING OPTIONS 5 2 3 SETTING UP MACH 3 GATEWAY 6 3 Gateway Configuration 8 3 1 OVE...

Page 4: ...5 1 Bridge 20 3 5 2 VPN 20 3 5 3 Open VPN 22 3 5 4 Port Forwarding 22 3 5 5 Source Network Address Translation 24 3 5 6 Routes 25 3 6 SETTINGS 26 3 6 1 Profile 26 3 6 2 Users Roles 26 3 6 3 Reset Use...

Page 5: ...ration Manual Simplifying IoT from edge to enterprise Revision History Revision Description Date 1 0 Initial release 1 4 2017 2 0 Revision 1 5 2018 3 0 Revision 8 1 2018 4 0 Revision 10 3 2018 5 0 Rev...

Page 6: ...ices used in the electric grid oil gas manufacturing and other applications The MACH 3 Gateway has a low power architecture which is capable of supporting industrial automation workloads while remaini...

Page 7: ...3 Installation and Configuration Manual Simplifying IoT from edge to enterprise 1 Overview 1 1 2 Right Side SIM Door View 1 1 3 Bottom View 3 39 1 66 1 22 0 97 Maximum length 1 25 6 32 mounting screw...

Page 8: ...temperature while operating the MACH 3 Gateway inside an enclosure Internal heating of the MACH 3 Gateway electronics other electronics and 2 Installing your MACH 3 Gateway the lack of ventilation in...

Page 9: ...antennae Non approved antennae may produce spurious or excessive RF transmitting power which may lead to a violation of FCC IC limits 2 2 Gateway Mounting Options 2 2 1 Bottom Mount 2 2 2 Din Rail Mou...

Page 10: ...ro SIM card in the SIM Card slot as shown in Figure 2 SIM Card Installation before turning on the MACH 3 gateway 4 The gateway power connector is a Molex Microfit 3 0 four pin connector wired as shown...

Page 11: ...0 VDC Switch in GND Switch in Figure 3 Power connector pinout Figure 2 SIM Card Installation Unscrew and remove the SIM door Replace and screw in the SIM door Slide SIM card into holder through openin...

Page 12: ...s seen in the navigation bar on the left side of the interface Each tab may contain multiple sections and each web based management page is used to configure a specific aspect of the Gateway DASHBOARD...

Page 13: ...lements of the Gateway It provides a high level view of the device and network interfaces as well as the GPS information 3 2 1 General Information Device name Classification of the MACH Gateway Device...

Page 14: ...curacy GPS readings accuracy GPS Fix Time Last fix from the GPS satellites 3 2 3 Cellular Information Status Indicates if the Cellular link is Enabled or Disabled PPP UP DOWN Indicates if the Cellular...

Page 15: ...Indicates if the Ethernet connection is Enabled or Disabled Link UP DOWN Indicates if the Ethernet link is UP or DOWN Link Speed Data rate on the Ethernet 1 eth0 Interface MAC Address MAC address of...

Page 16: ...e Ethernet is acting as STATIC IP DHCP Server or Bridge Tx Bytes Number of bytes transmitted since boot up Rx Bytes Number of bytes received since boot up 3 2 7 Wi Fi Client Status Indicates if the Wi...

Page 17: ...or SSID Service Set Identifier used to identify the WLAN Link UP DOWN Indicates if the Wi Fi link is UP or DOWN MAC Address MAC Address of the Wi Fi Access Point IP Address IP Address of the Wi Fi Ac...

Page 18: ...re used to configure the Wi Fi and Cellular radios on the MACH Gateway 3 3 1 Wi Fi Client In the Client mode the following configurations are seen Set the Enable button to use the Wi Fi in the Client...

Page 19: ...e the Wi Fi in the access point mode SSID Specify the wireless network name or SSID Service Set Identifier used to identify the WLAN Set the Broadcast SSID button if you want the SSID to be visible En...

Page 20: ...cellular network ICCID The Integrated Circuit Card Identifier ICCID is a 19 digit identification number for SIM Manufacturer The manufacturer of cellular modem in the MACH Gateway Model The model of c...

Page 21: ...and Ethernet 2 eth1 To configure Ethernet or Serial interface click the WIRED Tab on the left panel 3 4 1 Ethernet The two Ethernet ports have identical configuration elements The help guide applies t...

Page 22: ...he interface to other communication means such as Wi Fi etc select the BRIDGE in the MODE dialog box There is no IP address associated in this mode of operation 3 4 1 6 Firewall Group Under Advanced O...

Page 23: ...and can be one bit or two bits Set the STOP BITS switch to 1 to send one stop bit or set it to 2 to send two stop bits 3 4 2 7 Flow Control This setting informs the data receiver on how to process th...

Page 24: ...PN can be configured through Ethernet or Cellular 3 5 2 1 1 L2TP Ethernet To configure the VPN through Ethernet Set the L2TP TYPE switch to L2TP ETHERNET Enter the public IP address of the IPSEC serve...

Page 25: ...lic IP address of the L2TP Network Server in the L2TP LNS IP dialog box Enter the private IP address for the MACH Gateway in the L2TP LOCAL IP dialog box Enter the port number of the L2TP Network Serv...

Page 26: ...pdown list Set the COMPRESSION switch to ON to enable compression or set it to OFF to disable it Select TLS Security Type from the dropdown list and paste the TLS authentication or crypt key in PEM fo...

Page 27: ...s The default value is ANY PORT In display mode it shows the port number of the original destination In edit mode a dialog box is shown with the existing value of the original destination port number...

Page 28: ...E In display mode it shows if the particular rule row is enabled or disabled In edit mode it shows a dropdown list with values enabled or disabled The default value is enabled INTERFACE In display mod...

Page 29: ...AN The routing rules are represented in a tabular format The principle of adding changing deleting rules and refresh tables are the same as Port forwarding 3 5 6 1 Table Columns Fields ACTIONS It cont...

Page 30: ...add new users delete existing users and reset users password 3 6 2 1 Show All Users The users table displays all the other users of the MACH Gateway The table columns fields include ACTION It contain...

Page 31: ...of the user Type the password of the user The password must be six characters or more Select the preferred role for the user The selections are Admin OEM Users and Customer Click the Add button to re...

Page 32: ...he deletion was successful or not If the action was successful the user s row is removed from the table 3 6 3 Reset User s Password To reset the password of a user follow the steps below Click the Res...

Page 33: ...s The Roles table has two columns fields ROLES It displays the acceptable roles for the MACH Gateway USERS It displays users of the MACH Gateway based on their assigned role 3 7 SYSTEM The SYSTEM tab...

Page 34: ...lect the Image verification certificate The oem user should upload an OEM certificate while the customer user should upload a Customer certificate The admin user can upload either an OEM certificate o...

Page 35: ...set the Remote Support option follow the steps below Set the ENABLED button to ON to enable remote support or set it to OFF to disable it A pop up dialog appears and it warns the user about the inten...

Page 36: ...the applications table Machfu Apps These apps services can be uninstalled or closed from the table 3 7 3 2 Table Columns Fields ACTION This contains the delete icon for Machfu Apps This column appears...

Page 37: ...up dialog appears and it informs the user if the app has been uninstalled successfully or not The table refreshes automatically to show that the app has been removed uninstalled 3 7 4 Start Stop App T...

Page 38: ...34 Simplifying IoT from edge to enterprise MACH 3 Installation and Configuration Manual 3 Gateway Configuration The table refreshes automatically to show that the updated status of app...

Page 39: ...with antenna installation instructions and consider removing the no collocation statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 thi...

Page 40: ...greater than the maximum gain indicated for that type are strictly prohibited for use with this device Le pr sent metteur radio with model Mach3 Gateway a t approuv par Industrie Canada pour fonction...

Page 41: ...acement antenna NOTE Modifications to the device or use of unauthorized antennae as not expressly approved by Machfu is the sole responsibility of the user configurator or operator who must reassess t...

Page 42: ...38 Simplifying IoT from edge to enterprise MACH 3 Installation and Configuration Manual 5 3 Contacting Machfu For technical assistance or customer service issues please contact support machfu com...

Reviews: