Sensopress LCD 

 
 
 

 

 
 
 
 

User Guide 

 

 

 

 

 

Made in Italy 

 

Cod. /620020102 Dis.7208 Rev.00 06-2015 Eng

 

Summary of Contents for Sensopress LCD

Page 1: ...Sensopress LCD User Guide Made in Italy Cod 620020102 Dis 7208 Rev 00 06 2015 Eng...

Page 2: ...trical Connection 6 4 OPERATION AND USE 9 4 1 Front Panel Sensopress LCD 9 4 2 Visualization Menu 10 4 2 1 Auto Mode 10 4 3 Setting menu 11 4 3 1 CHANNEL Mode 12 4 3 2 LOW Mode 13 4 3 3 HIGH Mode 13 4...

Page 3: ...the product warranty null WARNINGS Sensopress LCD must be installed following the description on the Installation paragraph Sensopress LCD is an electric device possible water seepage in contact with...

Page 4: ...of water column measured in water cm Note all the visualized values are in mBar The correct value in water cm is obtained by augmenting the pressure in mBar of 2 1 973 a 4 C Sensopress LCD can be pro...

Page 5: ...UL94V0 Dimensions 105x90x73 mm Weight 450 g Protection degree IP20 Approval CE Sensors for Sensopress LCD Code PRS00B1A1M20000 Housing BRASS Principle operation Ceramic Capsule piezoresistive calibra...

Page 6: ...ed with a terminal to which is possible to connect the Sensopress LCD supply wires and also the connecting sensor s wires and those of the relay s output ATTENTION All the inner parts of the device ar...

Page 7: ...TURN 18 Supply Sensor 15V 19 20 Relay Output 10A 250Vac 10A 30Vdc 21 Contact Normally Closed NC 22 Contact Common C 23 Contact Normally Open NO 24 Figure 1 Connections for the version with a single ou...

Page 8: ...tput 4 2A 250Vac 2A 30Vdc 10 Normally Open NO 11 Common C 12 Normally Closed NC 13 14 15 Sensor 16 Sensor Mass 17 Riturn Sensor RETURN 18 Power Supply Sensor 15V 19 20 Relay Output 1 10A 250Vac 10A 30...

Page 9: ...hannel 1 10A 250Vac 10A 30Vdc 10A 250Vac 10A 30Vdc Channel 2 Not present 2A 250Vac 2A 30Vdc Channel 3 Not present 2A 250Vac 2A 30Vdc Channel 4 Not present 2A 250Vac 2A 30Vdc In the single output versi...

Page 10: ...vention s threshold referred to the chosen channel and specified on the display In Figure 4 the low threshold for channel 1 is 99 cm The high intervention threshold referred to the chosen channel and...

Page 11: ...AUTO Indicates The water s level in the tank The chosen channel The low and the high threshold set up for the chosen channel The relay s state of the chosen channel CHANNEL Only with the multi channe...

Page 12: ...nel by pushing the button Yes the chosen channel is indicated on the low left side of the display as shown in Figure 6 Push the button No to enable disable the indicated channel The indication of the...

Page 13: ...ssible to memorize the set up value and to pass to the changing state request if no button is pushed the device after a few minutes goes to the AUTO state Figure 7 To set up the low threshold of a cha...

Page 14: ...ANUAL Mode from any other mode by selecting the sign GO to MANUAL with the Menu button and by pushing Yes On the display it is shown the state name Manual and the relay position Relay OFF Relay ON and...

Page 15: ...timer that riactivate the timed backlight starts again by pushing any button With the Menu button we go to the request of state changing if no button is pushed the device goes to the AUTO state Figure...

Page 16: ...lso if entering the modes where this is requested At the end of this time the password to enter the mode where this is necessary is asked again The password is not necessary to enter the AUTO and the...

Page 17: ...d this there is the visualization of Figure 14 By pushing the No button it is possible to enter the procedure of zero setting By pushing the Yes button it is possible to enter on the procedure of the...

Page 18: ...the Yes button after entered the CALIB Make sure the sensor is put through the water column which needs to be set up On the display is visualized the screen of Figure 17 Figure 17 With the Yes and No...

Page 19: ...ply some specific loads the device may show anomalous behaviors The software is able to take measures and restore the correct operation If there are inductive loads particularly irksome with disturban...

Page 20: ...Sensopress_LCD_Rev_00_Eng doc Eng 20 Via Maestri del Lavoro 25 27 50013 Campi Bisenzio FI ITALY Tel 39 055 88 77 672 39 055 88 77 372 39 055 88 79 276 Fax 39 055 88 77 068...