background image

Tynetec, a business unit of Legrand Electric Ltd 

Cowley Road, Blyth Riverside Business Park, Blyth, Northumberland, NE24 5TF. 

Tel: +44 (0) 1670 352371    www.tynetec.co.uk 

Trusted Technology 

Caring for People 

Carbon Monoxide Alarm 
869MHz

 

Caring for People 

 
 

 

 
_________________________________________________________________________

 

________________________________________________________________ 

 
 

 
 

 

 

  Doc No. FM0824 V1.01 Page 1   

 

 

 

 

 

 
 

 

 

Compatible with Reach IP and Advent XT2 

 

Complies with BS EN 50291-1 & 2:2010 + A1:2012  

 

Advanced electrochemical sensor technology 

 

10 year sealed for life Lithium battery (typical) 

 

Wall mounted or free-standing 

 

Alarm sound level: 85dB(A) @ 3m 

 

Large central Test/Silence (

) button 

 

Operating Temperature: +4

o

C to +38

o

 

Telecare Transceiver: 869.2125MHz Class 1.5 

 

Weight: 193 grams 

 

Dimensions: 114mm x 94.5mm x 40mm  

 

Product Code: ZXT812 
 

Positioning

 

Carbon Monoxide (CO) alarms 

should be installed in 

every room containing a fuel-burning appliance and 
every sleeping room. 

When fitting in the same room as a 

fuel burning appliance the alarm should be at a horizontal 
distance between 1 and 3m from the potential source, if 
the room has a sloped ceiling it should be at the high side 
of the room. If the alarm is wall mounted it should be at 
least 150mm below the ceiling and at a height greater 
than any door or window. If the alarm is ceiling mounted 
it should be at least 300mm away from any wall or light 
fitting. If fitted in sleeping rooms the alarm should be 
located relatively close to the breathing zone of the 
occupants. Do not mount the alarm above any source of 
heat or steam. Refer to the 

Manufacturer’s instruction 

booklet for more information on positioning.

 

 

Alarm Condition

 

If a Carbon Monoxide leak is detected the unit will 
repeatedly sound 4 loud beeps and the red CO light will flash 
once every 5 seconds. Keep calm and open the doors and 
windows to ventilate the property. Stop using all fuel-
burning appliances and ensure, if possible, that they are 
turned off. Evacuate the property leaving the doors and 
windows open. Contact your Gas supplier on their 
emergency number. Do not re-enter the building until the 
alarm has stopped.

  

How Carbon Monoxide can affect you 

Refer to the Manufacturer’s instruction booklet for 

full 

details on the symptoms associated with increasing degrees 
of exposure to Carbon Monoxide. 

DANGER:

 

Never ignore any alarm, further exposure can be 

fatal. Get medical help immediately for anyone suffering the 
effects of Carbon Monoxide poisoning (e.g. headaches or 
nausea). Do not use the appliance again until it has been 
checked by a Gas Safe qualified engineer.

   

 

Normal Operation

 

The green power light will flash once every 60 seconds to 
indicate normal operation. 

 

Low Battery Condition

 

If the unit chirps every 60 seconds and the yellow warning 
light flashes at the same time, this indicates the battery is 
running low. The low battery condition will also be reported 
to the Alarm Receiving Centre (ARC) or the local Manager. 
The complete CO alarm should be replaced within 30 days.

 

 

Sleep Easy Feature 

Low battery warnings often start at night or when it may be 
inconvenient to replace the alarm. You can silence the 

audible ‘low battery’ chirp for a period of eight hours by 

pressing the Test/

 button. After this period the audible 

chirp will start again. This process can be repeated for a 
maximum of 10 times. The alarm will still detect CO during 
this time, however it must be replaced within 30 days.

  

 

Fault Condition

 

If the unit chirps every 60 seconds and the yellow warning 
light flashes 20-25 seconds after, this indicates a fault 
condition. Replace the CO alarm immediately.

 

 

Maintenance

 

Test the CO alarm once every week. 
Clean once every 3 months using a vacuum cleaner fitted 
with the soft brush attachment. 
Do not use solvents or cleaners on the CO alarm, the unit 
can be wiped with a damp cloth.

 

 

Disposal

 

Waste electrical products should not be disposed of with 
normal household waste. The CO alarm is ideally suited 
for disposal within the waste electronic and electrical 
equipment (WEEE) recycling scheme. Please recycle where 
facilities exist. Check with your local authority or contact 
your supplier for recycling/disposal advice.

 

 

Warning

 

The CO alarm contains a powerful Lithium battery. If 
tampered with the battery may be damaged and create a 
fire hazard. No attempt should be made to open the case 
or remove the battery. 