background image

39E Operating instructions 

 

Page

 

1 / 8

 

──────────────────────────────────────────────────────────────

 

SW V1.01 

11.09.2005  

                       La Gard Latin America - 741 Shotgun Rd. – Sunrise Florida – 33351 – USA 
                      Tel. +1 954 476 5574 – Fax. + 7 954 476 5576 – Email: [email protected] 

 
 

 

 

Table of content 

 

Table of content_____________________________________________________________1 

Hardware description ________________________________________________________2 

 

Keypad connector________________________________________________________2 

 

TAG reader connection to serial adapter _______________________________________ 2  

Alarm box connector______________________________________________________2 

 

Silent alarm output ________________________________________________________ 2  

Remote input_____________________________________________________________ 2  

Solenoid / motor connector_________________________________________________2 

 

Features ___________________________________________________________________3 

 

Codes & users __________________________________________________________3  

Time delay _____________________________________________________________3  

Battery low warning ______________________________________________________3  

Time penalty ____________________________________________________________3 

Programmable features ___________________________________________________3  

Audit __________________________________________________________________3  

Lock states _____________________________________________________________4 

 

Pre-setup mode___________________________________________________________ 4  

Special procedures __________________________________________________________4 

 

Setup process, to do list ___________________________________________________4 

Factory reset procedure ___________________________________________________4 

 

General procedures__________________________________________________________5 

 

To enter manager or user code _____________________________________________5  

To enter special function (manager or user)____________________________________5 

 

Open procedures ____________________________________________________________5 

 

To open (Standard mode)__________________________________________________5  

To open (Time Delay override mode) _________________________________________5  

To open (Dual code mode) _________________________________________________5 

 

Special functions_________________________________________________________ ___6 

 

To change code  

 

 

 

 

(special function #0) ___________6  

To install or reinstate user  

 

 

 

(special function #1) ___________6  

To disable user   

 

 

 

 

(special function #2) ___________6  

To delete user    

 

 

 

 

(special function #3) ___________6  

To get audit file   

 

 

 

 

(special function #7) ___________7  

To check user status    

 

 

 

(special function #7b) __________7  

To set mode and code length   

 

 

(special function #8) ___________8  

To change time delay and open window values  

(special function #9) ___________8

 

Summary of Contents for 39E

Page 1: ..._______________________________________________3 Lock states _____________________________________________________________4 Pre setup mode___________________________________________________________ 4...

Page 2: ...specifications are 1 200bauds no parity 8 data bits 1 stop bit PC and other serial devices may be connected to setup the lock and the get audit file Alarm box connector Standard 4 wires connector to...

Page 3: ...lay enabled LED flashes at two seconds intervals Open window is indicated by LED then buzzer at 1 seconds intervals alternately once LED once beep Battery low warning If battery low 6V during solenoid...

Page 4: ...anager function 8 Choose how many digits for manager and users codes Select standard mode without additional features Install users manager function 1 Install all users you need with default codes Del...

Page 5: ...t digit until double beep Enter special function number 0 9 Double beep if valid triple beep if not Open procedures To open Standard mode Enter code If time delay enabled wait open window Enter code a...

Page 6: ...if user blocked Enter new code Enter code again to confirm Double beep if correct triple beep if confirmation error Notes Manager only When enrolled he can install only users that were not blocked by...

Page 7: ...mission LED is still on a during search of audit beginning into memory Notes Manager only Audit file is automatically printed at each power up except in pre setup mode Audit printing may be stopped by...

Page 8: ...y and only if not enrolled his code was never changed Manager cannot choose dual code mode if no user installed nor active If code length is modified users codes are deleted and manager code is set to...

Reviews: