background image

1 / 4

66455-001
Rev 01
Vivint
Z-Wave® Plus

Installation and User Guide

E

N

G

L

IS

H

If drilling a new door, use the supplied template and the complete 
door drilling instructions available at www.kwikset.com/doorprep.

Note: Additional door preparation may be 
required for doors with 1-1/2" (38 mm) holes. 
Consult the deadbolt drilling instructions at 
www.kwikset.com/doorprep.

or

bac

kse

t

Measure to confirm that the hole in 
the door is either 2-1/8" (54 mm) or 
1-1/2" (38 mm).

Measure to confirm that the backset is 
either 2-3/8" or 2-3/4" (60 or 70 mm).

2-3/8" or 2-3/4"

60 or 70 mm

1-3/8" – 2"

35 – 51 mm

Measure to confirm that the hole in 
the door edge is 1" (25 mm).

Measure to confirm that the door is 
between 1-3/8" and 2" (35 mm and 
51 mm) thick.

A

B

C

D

2-1/8"

54 mm

1-1/2"

38 mm

1"

25 mm

1

Prepare the door and check dimensions

Required tools

Ruler

4 AA Batteries

Hammer

Wood block

Phillips head screwdriver

Additional Tools (depending on application)

A

N or P 

(2x)

N

P

S

Q

A

B

B

A

D

Is the door edge chiseled?

Which latch are you installing?

YES

NO

Use latch “A”. If the 
latch bolt is not already 
extended, extend the 
latch bolt as shown.

wood 
block

actual 

size

Use latch “B” (not 
included). If the latch 
bolt is not already 
extended, extend the 
latch bolt as shown.

Latch “A”

Latch “B”

(2x)

C

(2x)

Longer screws 
install closest to 
the door jamb.

door frame

E

Install strike on the door frame.

 Make sure the hole in the door frame is drilled a 

minimum of 1" (25 mm) deep.

or

chiseled

not 
chiseled

or

2

Install the latch and strike

Kwikset 

Technical Support

1-866-863-6584

www.kwikset.com

A

B

A

B

B

C

Is the D-shaped hole centered in the door hole?

Hold the latch in front of the door hole, with the latch 
face flush against the door edge.

YES

NO

No adjustment is required. 
Proceed to next step.

D-shaped hole

D-shaped hole

Rotate latch face as 
shown to extend latch.

or

Latch

“B” is not included. If needed, 

please contact Kwikset to order 

a drive-in latch for your lock.

Strike

C

Keys

E

 A

 B

Exterior Assembly

Adapter 
Ring

 D

Mounting 
Plate

Parts in the box

Fasteners

03809

46780

 N

 Q

 S

P

66128

64109

 T

 V

49191

 U

Interior Assembly

SmartKey  
Tool

H

M

F

K

L

G

Summary of Contents for Smartcode 888

Page 1: ... D Is the door edge chiseled Which latch are you installing YES NO Use latch A If the latch bolt is not already extended extend the latch bolt as shown wood block actual size Use latch B not included If the latch bolt is not already extended extend the latch bolt as shown Latch A Latch B S 2x C Q 2x Longer screws install closest to the door jamb door frame E Install strike on the door frame Make s...

Page 2: ...ng plate A A A B B C D B C Diameter is 2 1 8 54 mm Diameter is 1 1 2 38 mm or D is required for installation Install D on F D is not needed for installation Discard D Cable goes underneath latch Support exterior assembly during mounting plate installation Route cable through center hole then push cable into bottom hole Insert key and test latch If latch does not extend or retract smoothly adjust s...

Page 3: ...attery pack or back panel slide up the window on the interior cover Locking the Door Unlocking the Door Re Key with SmartKey Enter user code A total of 30 user codes may be programmed Press Lock button once A A B B C What lights and sounds does the lock produce D Each user code must be a unique code between 4 and 8 digits depending on your smart home system Programming was successful Programming w...

Page 4: ...ssure interoperability each Z Wave product must pass a stringent conformance test to assure that it meets the Z Wave standard for complete compliance with all other devices and controls The Z Wave identity mark assures consumers integrators dealers and manufacturers that their products will reliably perform with any other Z Wave device And regardless of the vendor always powered nodes may act as a...

Page 5: ...tion Parameters The Z Wave door lock module supports the use of the configuration command class to provide advanced configuration of the door lock over the Z Wave network This section describes the configuration parameters supported by the door lock 2 1 Configuration Parameters 33 and 34 Parameter Name SKU length 8 bytes Data Length 4 bytes each parameter Default Values for 33 and 34 0x20 0x20 0x2...

Page 6: ...ng a set command with the default field set to 1 will cause the control to revert back to its factory default setting 2 3 Configuration Parameter 36 Parameter Name Auto lock Feature Control Data Length 2 bytes Default Values Byte 1 0 disabled Byte 2 0x1E HEX 30 seconds Possible Values Byte 1 1 enabled 0 disabled Byte 2 30 60 90 120 180 all in seconds Description The configuration parameter 36 uses...

Page 7: ...40 is a one byte field used to set the lock to its default setting known as a factory reset command Reading this parameter will always return a value of 0 Writing a value of 1 to this parameter will cause both the lock and Z Wave card to reset back to their default settings and will remove itself from the network All network information including associations will be cleared 2 6 Configuration Para...

Page 8: ...k and will remove it from your smart home system It will not remove any anti theft settings Please use the local reset procedure only when the primary controller is missing or inoperable 5 1 Local 1 Remove battery pack and press the program button a few times to discharge 2 Press and hold the program button 3 Replace the battery pack 4 Continue holding the program button for 30 seconds until the l...

Reviews: