background image

INSTRUCTION MANUAL

ENGLISH

600V

10A

2M

Ω

•  LEAD ALERT 

PROTECTION

•  DATA HOLD
•  AUDIBLE 

CONTINUITY

•  BATTERY TEST
•  DIODE TEST
•  AUTO 

POWER-OFF

Manual-Ranging 

Digital Multimeter

5000573

MM325

CAT III

600V

2m

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for 092644693731

Page 1: ...Ω LEAD ALERT PROTECTION DATA HOLD AUDIBLE CONTINUITY BATTERY TEST DIODE TEST AUTO POWER OFF Manual Ranging Digital Multimeter 5000573 MM325 CAT III 600V 2m www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 2: ... outside of Accuracy Temp range Dimensions 6 41 3 13 1 83 162 7 79 4 46 6 mm Weight 8 8 oz 250 g Calibration Accurate for one year Standards IEC EN 61010 1 61010 2 030 61010 2 033 IEC EN 61326 1 61326 2 2 Conforms to UL STD 61010 1 61010 2 030 61010 2 033 Certified to CSA STD C22 2 NO 61010 1 61010 2 030 61010 2 033 Pollution degree 2 Accuracy of reading of least significant digits Drop Protection...

Page 3: ...Ω 0 8 3 digits 2000Ω 1Ω 20 00kΩ 0 01kΩ 200 0kΩ 0 1kΩ 2000kΩ 1kΩ 1 0 3 digits Battery Test 9V 10mV 1 0 2 digits 1 5V 1mV Diode Test Approx 1 0mA open circuit voltage 2 0V DC Continuity Check Audible signal 50Ω Battery Test 9V approx 20mA 450Ω load 1 5V approx 15mA 100Ω load Sampling Frequency 2 samples per second Overload OL indicated on display overload protection 600V RMS in all settings Polarity...

Page 4: ...5V AC RMS or 60V DC Such voltages pose a shock hazard To avoid false readings that can lead to electrical shock replace batteries when a low battery indicator appears Do not attempt to measure resistance or continuity on a live circuit Always adhere to local and national safety codes Use personal protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed...

Page 5: ...tion selector switch 3 10A jack 4 COM jack 5 VΩ jack 6 HOLD Data Hold button 7 Backlight button 8 Lead Alert LEDs NOTE There are no user serviceable parts inside meter 3 5 4 8 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 6: ...wer OFF symbol will not be visible in the display HOLD DATA HOLD Press the HOLD button 6 to hold the measurement on the display Press again to release the display and return to live measuring BACKLIGHT Press and hold the Backlight button 7 for more than one second to turn the backlight on or off Backlight automatically turns off after approximately 3 minutes LEAD ALERT LEDs When the Function Selec...

Page 7: ...ot to lose the shields 0 7 18 mm 5 32 4 mm 5 32 4 mm AC VOLTAGE LESS THAN 600V 1 Insert RED test lead into VΩ jack 5 and BLACK test lead into COM jack 4 and rotate Function Selector Switch 2 to the highest V AC setting 600V 2 Measure voltage and rotate the Function Selector Switch to successively lower V AC settings to obtain higher resolution measurements NOTE The hazardous voltage indicator will...

Page 8: ...age and rotate the Function Selector Switch to successively lower V DC settings to obtain higher resolution measurements NOTE When in a voltage setting and the test leads are open readings of order mV may appear on the display This is noise and is normal By touching the test leads together to close the circuit the meter will measure zero volts NOTE The hazardous voltage indicator will appear for v...

Page 9: ...ng currents greater than 6A a measurement time of 30 seconds followed by 10 minutes of recovery time is recommended RESISTANCE MEASUREMENTS 1 Insert RED test lead into VΩ jack 5 and BLACK test lead into COM jack 4 and rotate Function Selector Switch 2 to the highest Ω setting 2MΩ 2 Remove power from circuit 3 Measure resistance by connecting test leads to circuit and rotating the Function Selector...

Page 10: ...o positive terminal of battery 3 Measure voltage on display batteries in good condition should be within approx 10 of rated voltage Red lead Black lead Red lead Black lead OPERATING INSTRUCTIONS CONTINUITY 1 Insert RED test lead into VΩ jack 5 and BLACK test lead into COM jack 4 and rotate Function Selector Switch 2 to the setting 2 Remove power from circuit 3 Test for continuity by connecting con...

Page 11: ... Klein Cat No 69031 10A jack 3 10A 600V fast blow interrupting rating 10kA Klein Cat No 69032 3 Replace battery door and fasten securely with screw To avoid risk of electric shock disconnect leads from any voltage source before removing battery door To avoid risk of electric shock do not operate meter while battery door is removed To avoid risk of electric shock disconnect leads from any voltage s...

Page 12: ... limits mentioned in the General Specifications section allow the meter to return to normal operating conditions before using FCC IC COMPLIANCE See this product s page at for FCC compliance information Canada ICES 003 B NMB 003 B WARRANTY DISPOSAL RECYCLE Do not place equipment and its accessories in the trash Items must be properly disposed of in accordance with local regulations Please see www e...

Reviews: