background image

 

 

 

 
  

 

 

 

Ethernet Switch 

User Manual 

 

 

 

ESUG4P-PG2 

 

 

 

Summary of Contents for ESUG4P-PG2

Page 1: ...Ethernet Switch User Manual ESUG4P PG2 ...

Page 2: ...5 2 1 PACKAGE CONTENTS 5 2 2 CONFIGURATIONS 5 2 2 1 Physical Connections 6 2 3 INSTALLATION METHOD 7 2 3 1 DIN Rail Mount 7 2 3 2 Wall mount 7 2 4 ETHERNET RJ45 CONNECTIONS 7 2 5 SFP PORTS 8 2 6 POWER CONNECTIONS 8 2 7 FAULT ALARM CONTACT 9 2 8 LED STATUS 10 3 TROUBLESHOOTING 11 3 1 SELF TESTING 11 4 SYSTEM EXAMPLE 12 5 DIMENSIONS 12 6 WARRANTY 13 6 1 WARRANTY INFORMATION 13 6 2 CLASS A ITE 14 6 3...

Page 3: ...he units have redundant power supply terminals and an alarm output All copper ports are automatically configured and the plug and play design provides ease and speed of installation 1 1 1 ESUG4P PG2 The ESUG4P PG2 provides connectivity for up to four 10 100 1000 RJ45 twisted pair copper ports which are capable of simultaneously supplying IEEE802 3at PoE and two gigabit SFP ports Each of the four 1...

Page 4: ...ation Standard IEEE 802 3 Transmission distance 100m PoE Physical port 4 x shielded RJ45 Standard IEEE 802 3at Power supplied per port 30W 55Vdc Electromagnetic compatibility Interference EN55022 Class A Immunity IEC61000 6 2 Power Input voltage 50 57Vdc Power consumption 5 5W no PoE 125 5W full load PoE Power supply Supplied separately Environmental Operating temperature 40 C 74 C 40 F 165 F Stor...

Page 5: ...th DIN rail mount 2 x Wall mount brackets with screws Pluggable terminal block Quick Start Guide Note A 50 57Vdc PSU is required but supplied separately Please contact you dealer or distributor if a part is missing or damaged 2 2 Configurations Products are available in either DIN rail or wall mount packages with the following configurations Product Type DIN Rail Wall mount ESUG4P PG2 ...

Page 6: ...Ethernet Switch User Manual Manual ESUG4P PG2_Series_HW Rev1201 Copyright KBC Networks Ltd Page 6 of 15 www kbcnetworks com 2 2 1 Physical Connections Top View ...

Page 7: ...witch using the screws that have just been removed from the DIN rail mounting plate with a Phillips No 1 or No 2 screwdriver Position the unit on the required flat surface and secure with screws via the mounting plate holes Screws are not provided Attach copper cables as required Insert the male power block attached to the supplied in line PSU to the female power socket on the device and tighten t...

Page 8: ... LX BX ZX in any permutation 2 6 Power Connections A 6 pin power terminal block should be used to connect the power cable to the unit V V 2 3 4 5 6 1 V V Figure 2 1 Power connections Contact number Connections 1 PWR2 2 PWR2 3 Fault alarm contact 4 Fault alarm contact 5 PWR1 6 PWR1 Note If only using one power source connect pin 1 to pin 5 and pin 2 to pin 6 otherwise the Power Fault Alarm will be ...

Page 9: ... Page 9 of 15 www kbcnetworks com 2 7 Fault Alarm Contact The fault alarm contacts are in the middle of the 6 pin screw block terminal on pins 3 4 An open circuit will occur if a power failure is detected Fig 2 2 Fault Alarm Contacts 2 3 4 5 6 1 Load External power 24Vdc 1A resistance P Fail ...

Page 10: ...ered device OFF There is no powered device attached or the power to the device has failed P5 P6 ON SFP port link established FLASH Active data flow OFF No connection to the network Ethernet RJ45 Ports P1 to P4 Status LED Each RJ45 Ethernet port has two green indicators an upper and lower The upper one indicates the state of the port link and the lower one indicates port link speed Lower LED ON Por...

Page 11: ...pective inputs or not If problems are encountered when using this Ethernet switch please check the following Verify that the correct power supply unit is being used this unit requires a 48Vdc supply Ensure that the correct cables are being used to construct your network o Unshielded Twisted Pair or Shielded Twisted Pair for RJ45 connections o 100Ω Cat 3 cable or above for 10Mbps connections o 100Ω...

Page 12: ...thernet Switch User Manual Manual ESUG4P PG2_Series_HW Rev1201 Copyright KBC Networks Ltd Page 12 of 15 www kbcnetworks com 4 System Example Figure 4 1 ESUG4P PG2 Typical System Application 5 Dimensions ...

Page 13: ...al shock exposure to moisture and circuit modification b SHOULD THIS PRODUCT PROVE DEFECTIVE FOLLOWING PURCHASE THE BUYER NOT THE MANUFACTURER DISTRIBUTOR OR RETAILER ASSUMES THE ENTIRE COST OF ALL SERVICING OR REPAIR EXCEPT AS OTHERWISE PROVIDED BY THE TERMS OF THIS WARRANTY c FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY ON THIS PRODUCT THE BUYER IS LIMITED TO THE FOLLOWING DAMAGES 1 THE COST OF...

Page 14: ...nment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful Interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at this own expense 7 Instruction of Dis...

Page 15: ...630 U S A Americas Phone 1 949 297 4930 Fax 1 949 297 4933 KBC Networks Ltd EMEA KBC Networks Ltd Barham Court Teston Maidstone Kent ME18 5BZ United Kingdom Phone 44 0 1622 618787 Fax 44 0 20 7100 8147 Email info kbcnetworks com Web www kbcnetworks com data delivered ...