background image

KAEL 

Mühendislik Elektronik Tic. ve San. Ltd.Şti

.

www.kael.com.tr

DC MULTIMET

ER and ENERGOMETER

ISO 9001:2008

■ 

DC 

Current

 (with Shunt Resistance) 

 Programmable

 (50-100mV)

DC-MULTISER-1UH-DIN

■ 

DC 

Current

 0-300V 

dc

■ 

DC 

Power

■ 

DC 

Energy

■ 

Relay

 Output

■ 

Digital 

input

■ 

Pulse

 Output

■ 

Analogue

 Output

(programmable)

■ 

RS

 4

85

 –

 M

OD

BU

RTU

4-

20

m

   

 0

-2

0m

A

0-

10

   

   

 2

-1

0V

0-

5V

  

  1

-5

V

■ 

DC 

Current

 0-1200V 

dc

■ Auxiliary 

Supply 

Voltage

85-265Vac 

 or

 100-300Vdc

■ 

Auxiliary Supply Voltage

i

18

-7

5V

dc

DC-MULTISER-1OH-DIN

DC-MULTISER-1OL-DIN

DC-MULTISER-1UL-DIN

1

2

1

1

1

2

1

1

1

2

1

1

1

2

1

1

DC-MULTISER-2UH-DIN

DC-MULTISER-2OH-DIN

DC-MULTISER-2OL-DIN

DC-MULTISER-2UL-DIN

Green Power Measurement Device,

■ 

Dimensions

 (105x90x59 

mm)

■ Easy use via menus with shortcuts
■ DC current, voltage and power values can be simultaneously monitored.
■ 

Four different types of energy measurement as total, positive, negative and difference can 

be fulfilled.

■ Secondary part of shunt resistance can be set between 50 mV and 100mV

■ Voltage, current and power alarms 
■ Multiple alarms 
■ Password protection

Measurements

■ Voltage
■ Current
■ Active Power
■ Active Energy

input

 and out

puts

■ Relay output (1 pc)
■ Pulse output (1 pc )
■ Digital inputs ( 2 pcs )
■ Analogue output ( 1 pc )
■ RS-485 MODBUS-RTU

DC- MULT

IMETER and ENERGOMETER MODELS

Summary of Contents for DC-MULTISER-1UH-DIN

Page 1: ...1 1 1 2 1 1 1 2 1 1 1 2 1 1 DC MULTISER 2UH DIN DC MULTISER 2OH DIN DC MULTISER 2OL DIN DC MULTISER 2UL DIN Green Power Measurement Device Dimensions 105x90x59 mm Easy use via menus with shortcuts DC...

Page 2: ...f the system presents power quality problems insulation transformer or EMC filter should be used for auxiliary power supply Switch board cover or protection sheet With our DC MULTISER devices dc curre...

Page 3: ...t Connections AC DC AC DC Power Supply Relay Power Supply Digital Input Connections max 30Vdc Com DI2 Connect 1 5 2 5 mm cable Power Supply Optical Insulation Optik izolasyon DI1 Optical insulation An...

Page 4: ...eters menu At this stage HHHH is displayed in the line at the bottom of the screen while the password screen flashes When SET key is pressed 0000 figures are displayed in the most bottom line and the...

Page 5: ...arity no even odd Stop Bits May be set as 1 1 5 or 2 Baud rate It may be set as 2400 4800 9600 19200 28800 38400 57600 or 115200 Device No 001 255 SET SET SET SET Relay Contact Position nO normally sw...

Page 6: ...Momentary mode In this mode as an extra the time seen in the adjacent box is displayed It may bet set between 300 msn and 5000msn When alarm is set alarm relay remains pulled until the end of this tim...

Page 7: ...e Curr Over dELy It may be set between 1 300 sec If the measured voltage exceeds the set voltage value the relay contact is released at the end of the delay time Over Current Mistake Repair Time Curr...

Page 8: ...rrent Delay Time Curr Undr dELy It may be set between 1 300 sec If the measured current falls below set current value relay contact is released at the end of the delay time Low Current Mistake Repair...

Page 9: ...s disabled alarm relay releases Latch mode when alarm mode is set alarm relay is pulled Alarm relay remains pulled even the alarm is disabled If latch mode iset in models with alarm function alarm sho...

Page 10: ...disregarding the symbol of the measured value In this mode measred value may be set between 100 This menu is displayed when PErC is selected in the Analogue measurement range An rAng This screen does...

Page 11: ...utputs Measurement Value Analogue output value 2 5 V 5 V 5 V Voltage V 0 10 V Example 1 Voltage Full Scale Setting Analogue Parameters Voltage Output Type Analogue Operation range setting PERC PERC up...

Page 12: ...arm mode 10 sec 10 sec Over Current Set Value Curr Over Val Over Current Alarm Permit Curr Over EnbL Over Current Alarm Mode Setting Curr Over tYPE Over Current Delay Time Curr Over dELy Over Current...

Page 13: ...t Type Current Output Type Accuracy Load Capacity 0 10V 2 10V 0 5V 1 5V 0 20mA 4 20mA 0 2 In current type max load resistance 750 Ohm In voltage type load current max 20 mA Updating Duration 200ms 6 R...

Reviews: