EQUIPMENT OVERVIEW

This is a compact CAT III 300V rated multimeter for measuring DC and 
AC voltage, DC current, resistance, continuity, diode and batteries. A 
short summary of the features of this equipement is listed below:  

• 

CAT III 300V Digital Mulitmeter 

• 

3.5 Digit LCD Display (Maximum reading 1999)

• 

Data Hold Function & Overload Protection

• 

Low Battery Indication 

• 

Negative Polarity Indication

• 

Continuity and Diode Testing

• 

Battery Testing: 1.5V / 9V / 12V

• 

Resistance Measurements: Up to 2000KΩ

• 

Manufactured & tested to IEC 61010

SPECIFICATIONS

DC Voltage Range: 

200m ~ 300V

DC Current Range: 

2000μ ~ 10A

AC Voltage: 

200 ~ 300V

Input Impedance: 

1MΩ

Resistance: 

200 ~ 2000kΩ

Continuity: 

less than 30Ω

Diode Testing:  

2.8V (approx) 

Test Current: 

1mA

Battery Testing

1.5V / 9V / 12V 

Overload Protection: 

Both Fuses: ø5x20mm

F1: Fuse, 250mA / 300V, Fast action
F2: Fuse, 10A / 300V, Fast action

Power Supply: 

1x 9V Battery

Dimensions: 

138 x 74 x 32mm

Weight: 

160g (including battery)

ELECTRICAL SYMBOLS

This equipment should only be used by fully trained, qualified and 
responsible personel. The following list of common electrical symbols 
is provided for reference: 

Alternating Current (AC) 

Direct Current (DC) 

Both Alternating and Direct Current AC/DC

Earth (ground) Terminal 

Fuse

Double or reinforced insulation protection

Caution: Risk of electric shock

SAFETY

•  

Always check this equipment before use. In particluar ensure that 

you check the case and insulation surrounding the connectors. Inspect 
the test leads for damaged insulation or exposed wiring. Replace the 
test leads if any defects are identified .Do not use the equipment if any 
damage or defect is found.

•  

Do not operate the meter in environments where explosive gas, vapor 

or dust is present. 

•  

You can test that the meter is functioning correctly by measuring a 

known voltage before use. 

• 

Never exceed the rated voltage, as marked on the meter, between 

terminals or between any terminal and earth ground. 

•  

When using the probes, ensure you keep your fingers behind the 

finger guards. 

• 

Connect the common test lead before connecting the live test lead. 

When disconnecting test leads always disconnect the live test lead 
first. 

• 

Remove the test leads from the meter before opening a battery cover 

or case. 

•  

Do not operate the meter with a battery cover that is removed or 

loose. 

•  

Avoid touching conductors with hands or skin. 

• 

Never use the equipment in wet conditions or when hands or skin are 

wet. 

• 

Do not use the equipment if any part of it or the test leads are wet. 

•  

Please note that where an input terminal is connected to dangerous 

live potential, the potential can occur at all other terminals.  

This equipment is suitable for use for CAT III rated measurements 
only and should not be used on equipement that requires CAT IV. 
Check compatibility before use. 

• 

Disconnect circuit power and discharge all capacitors before testing 

resistance, diode, continuity or temperature (where applicable). 

• 

Always use the proper terminals, function and ranges specified for 

your equipment. Contact Jefferson Tools for advise if you are unsure 
about any aspect of the functionality of this equipment. 

•  

When measuring current always turn off the circuit power before 

connecting the meter. Remember to place the meter in series with the 
circuit. 

• 

Always take precautions when working with voltages exceeding 30V 

AC RMS, 42V Peak or 60V DC. 

• 

Always disconnect the test leads before rotating the range switch to 

change functions. 

Important: 

Always replace the battery as soon as the 

low battery indicator appears on the display. Never 