background image

UC-280 wireless interface

1 / 2

MFT51202

UC-280 Wireless Interface

The UC-280 is an 8-zone interface linking JA-60 wireless detectors

with hard-wired security control panels. It can also send triggering
signals to a JA-60A wireless outdoor siren and/or UC-216 and UC-222
universal receivers. Additionally, it can receive signals from Jablotron
RC-xx remote controls. If necessary, UC-282 expander modules can
be used to increase the number of zones up to 40.

Specification

Power

12 V DC (10.5 V – 16.0 V)

Power consumption

typ. 50 mA (all relays off)
max. 150 mA

Zone outputs Z1-Z8

8 relays 50 mA / 50 V
with COM1 common terminal

Tamper, fault, battery outputs

3 relays 50 mA / 50 V
with COM2 common terminal

X, Y and Siren inputs

activated when switched to GND
(filter 0.2 sec., 3 V DC triggering
level)

Operating frequency

433.9 MHz

Working range with JA-60

100 m (open area)

Working range with RC

30 m (open area)

Working environment

indoor use (class II, EN 50131-1)

Operating temperatures

-10 °C to +70 °C

Operating humidity

max. 90 %

Dimensions

188 x 135 x 40 mm

Weight

800 g

Purchase package contains: electronic board, metal case, antenna,
screws, dowels, and manual.

Installation

The UC-280 is an electronic module built-in to a metal case

(protected by a tamper switch). The case should be installed on a wall
with its antenna in a vertical position. The device should not be

installed close to any metal structures or other objects obstructing radio
signal transmission.

Route the wires through the hole in the rear part of the housing.

Attach the case to the desired place using the provided screws.
Connect the antenna and the tamper switch.

Terminals:

Z1-Z8

Zone 1-8 output relays’ contacts, max. 50 mA / 50 V, pulse
length can be set by 1s/3s jumper, normally closed or
normally opened mode is selected by the NO/NC jumper

COM1

common terminal of Z1-Z8 relays

TMP

tamper relay output (tamper signal from wireless detectors,
a wireless siren and the UC-280 tamper switch), max. 50 mA
/ 50 V

BAT

low battery relay output (low battery signal from wireless
detectors 1-8 or a wireless siren), max. 50 mA / 50 V

TRB

trouble relay output (trouble signal from wireless detectors
1-8 or a wireless siren - e.g. lost communication), max.
50 mA / 50 V

COM2

common terminal of TMP, BAT and TRB relays

GND

power supply ground terminal

SIR

triggering input for activation of JA-60A wireless siren (the
siren sounds as long as this input is closed to GND, max.
15 minutes)

X

input, which can trigger relay X of a UC-216 or UC-222
universal receiver when switched to GND

Y

input, which can trigger relay Y of a UC-216 universal
receiver when switched to GND

OUT

input, which can trigger output OUT of a UC-216 universal
receiver when switched to GND

+12V

power voltage terminal

TAMPER a pair of terminals used for the connection of the UC-280

case tamper switch

Reviews: