1. GENERAL INFORMATION

Matrix

 

III EH Reader

 

is 

used in Access Control Systems (ACS). The reader transmits into the 

controller the codes of EM-Marine or HID

 

ProxCard II

 tokens (cards or key fobs) presented to it, via 

iButton (Dallas Touch Memory) or Wiegand-26 protocols. 

2. OPERATION 

The  reader  operation  without  activating  external  indication  control  (i.e.  staying  under  internal 
indication control):
1. In standby mode, the red LED shines solid.
2. On card approach, the red LED goes off and the green LED flashes once, and a short beep 
sounds.
3. While the card remains within working zone, no LED indication is provided.

The external indication control for the LEDs and the buzzer is initiated by connecting corresponding 
terminals to common ground. The external indication control for one mode can be used with internal 
indication control for another; if, for instance, external indication signal for LEDs is activated, the 
LEDs get under external control, while the buzzer remains under internal control. 

3. MOUNTING AND CONNECTION

To mount the reader, perform the following sequence:
-  Mark and drill the mounting holes per Fig. 2;
-  Connect the reader wires 

according to

 Table 1;

-  Insulate all wire junction points;
-  Power up the device (the red LED will come on);
-  Test the reader operation by touching it with a token;
-  Mount the reader in its desired place and fix it with screws;
-  Install the decorative cover and fix it with a screw.

Note 1: Leave 10 cm or more between any two readers.
Note 2: To achieve the specified distance from controller, a UTP cable (e.g. CAT5e compatible) 
must be used as follows:
-  When using iButton protocol, one wire from the twisted-pair should be connected to GND and 
another to DATA0 terminal.
-  When using Wiegand 26 protocol, the first twisted pair is connected between GND and DATA0, 
and the second one between GND and DATA1, as per Fig. 1.

page 1

MATRIX III EH

www.ironlogic.

me

Summary of Contents for Matrix III EH

Page 1: ... one mode can be used with internal indication control for another if for instance external indication signal for LEDs is activated the LEDs get under external control while the buzzer remains under internal control 3 MOUNTING AND CONNECTION To mount the reader perform the following sequence Mark and drill the mounting holes per Fig 2 Connect the reader wires according to Table 1 Insulate all wire...

Page 2: ... for audial and visual indication Case material ABS plastic Dimensions 120 45 22 mm Figure 1 Choosing the transmission protocol Figure 2 Device Dimensions DATA1 GND D0 DATA0 D1 GND D0 iButton D1 GND D0 iButton D1 IButton One time transmission Wiegand IButton DS1990A emulation ACS controller Reader GND GND GND screw 120 mm 82 mm 45 mm Wire Colour Wire Designation Red 12V Black Common White DATA0 Br...

Page 3: ...warranty for 24 months The warranty becomes void if this Manual s guidelines are not followed the device has suffered physical damage the device has visible traces of exposure to moist and or aggressive chemicals the device circuits have visible traces of tampering by unauthorised parties Under this warranty the Manufacturer shall repair the device or replace any broken parts as required free of c...

Page 4: ... E mail info ironlogic lv headstaff ironlogic lv Phone 37166181894 37124422922 www ironlogic me The symbol of crossed throught waste bin on wheels means that the product must be disposed of at f separate collection point This also applies to the product and all accessories marked with this symbol Products labeled as such must not be disposed of with normal household waste but should be taken to a ...

Reviews: