  PROTOCOL CONVERSION FEATURE CONVERTS NUMEROUS 

PROTOCOLS SIMULTANEOUSLY

  COMPACTFLASH

®

 SLOT ALLOWS PROCESS DATA TO BE 

LOGGED DIRECTLY TO CSV FILES

  VIRTUAL HMI OFFERS BUILT-IN PC-BASED SCADA 

FUNCTIONALITY

  WEBSERVER PROVIDES WORLDWIDE ACCESS TO DATA 

LOGS AND VIRTUAL HMI

  EXTENSIVE BUILT-IN DRIVER LIST ALLOWS EASY DATA 

MAPPING TO PLCs, PCs, AND SCADA SYSTEMS

  ALARM NOTIFICATIONS CAN BE SENT VIA EMAIL OR TEXT 

MESSAGES

  10 BASE-T/100 BASE-TX ETHERNET CONNECTION  

CAN CONNECT TO AN UNLIMITED NUMBER OF  

DEVICES VIA FOUR PROTOCOLS SIMULTANEOUSLY

GENERAL DESCRIPTION

The Data Station Plus was designed to act as a nexus for industrial data 

collection and management. The unit offers multiple protocol conversion, data  

logging and remote machine access. With three built in serial ports and a 10 

Base-T/100 Base-TX Ethernet port, the unit performs protocol conversion, 

allowing disparate devices to communicate seamlessly with one another. The 

Ethernet port supports up to four protocols simultaneously so even Ethernet to 

Ethernet protocols can be converted.

The CompactFlash card allows data to be collected and stored for later 

review. The files are stored in simple CSV file format allowing common 

applications, such as Microsoft Excel and Access, to view and manage the data. 

The free Websync utility provides a means to synchronize the files with a PC’s 

hard drive for permanent storage. The CompactFlash card may also be used to 

load new configuration files into the Data Station.

The built-in web server allows log files to be retrieved manually, and also 

provides access to the unique “virtual HMI”. The virtual HMI is programmed 

just like Red Lion’s G3 series of HMI. Any standard web browser such as 

Internet Explorer or Netscape may be used to monitor or control the HMI from 

a PC anywhere in the world.

The USB port may be used for blazing fast file downloads, or to mount the 

Data Station’s CompactFlash card as an external drive to your PC.

The Data Station’s DIN rail mounting saves time and panel space and snaps 

easily onto standard top hat (T) profile DIN rail.

SOFTWARE

The Data Station is programmed with Crimson

®

 2.0 software for Windows

® 

 

2000 or later platforms. The software is an easy to use graphical interface which 

can be purchased as part of a kit that includes a manual and cables, or 

downloaded free of charge from www.redlion.net.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the 

manual or on equipment must be observed to ensure personal safety and to 

prevent damage to either the instrument or equipment connected to it. If 

equipment is used in a manner not specified by the manufacturer, the protection 

provided by the equipment may be impaired.

Do not use the controller to directly command motors, valves, or other 

actuators not equipped with safeguards. To do so can be potentially harmful to 

persons or equipment in the event of a fault to the controller. An independent 

and redundant temperature limit indicator with alarm outputs is strongly 

recommended.

CompactFlash is a registered trademark of CompactFlash Association.

MODEL DSP – DATA STATION PLUS

Bulletin No.  DSP-K
Drawing No.  LP0629
Released  11/13

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

CAUTION: Risk of Danger.

Read complete instructions prior to  

installation and operation of the unit.

5.30 (134.7)

RS232

ETHERNET

CF

STS

USB/PG

RS485

RS232/PG

3.09 (78.5)

4.15 (105.4)

DIMENSIONS  In inches (mm)

FOR USE IN HAZARDOUS LOCATIONS: 

Class I, Division 2, Groups A, B, C, and D

C

US LISTED

UL

R

3PWL

PROGRAMMABLE 

CONTROLLERS

C

US LISTED

UL

R

IND. CONT. EQ.

34AD

WARNING - EXPLOSION HAZARD - SUBSTITUTION OF 

COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, 

DIVISION 2

THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS I, 

DIVISION 2, GROUPS A, B, C, D, OR NON-HAZARDOUS 

LOCATIONS ONLY

Summary of Contents for DSPSX000

Page 1: ...e in the world The USB port may be used for blazing fast file downloads or to mount the Data Station s CompactFlash card as an external drive to your PC The Data Station s DIN rail mounting saves time and panel space and snaps easily onto standard top hat T profile DIN rail SOFTWARE The Data Station is programmed with Crimson 2 0 software for Windows 2000 or later platforms The software is an easy...

Page 2: ...EC 68 2 27 Operational 30 g Altitude Up to 2000 meters 7 CONSTRUCTION Case body is burgundy high impact plastic and stainless steel For indoor use only Installation Category II Pollution Degree 2 8 POWER CONNECTION Removable wire clamp screw terminal block Wire Gage Capacity 24 AWG to 12 AWG Torque 4 45 to 5 34 in lb 0 5 to 0 6 N m 9 MOUNTING Snaps onto standard DIN style top hat T profile mountin...

Page 3: ...esome installation Listed are some EMI guidelines for a successful installation in an industrial environment 1 A unit should be mounted in a metal enclosure which is properly connected to protective earth 2 Use shielded cables for all Signal and Control inputs The shield connection should be made as short as possible The connection point for the shield depends somewhat upon the application Listed ...

Page 4: ...S485 USB PG RS232 PG ETHERNET CF STS CBLxxxxx CHASSIS GND OR CBLPROG0 REM SLC 5 03 CPU RUN BATT FLT RUN RS232 DH485 FORCE PROG VDC PWR OUT 24 PWR OUT COM VAC NEUT 120 240 VAC USER POWER POWER RS232 PG USB PG RS232 PG ETHERNET WARNING EXPLOSION HAZARD DO NOT DISCONNECT WHILE CIRCUIT IS ALIVE UNLESS AREA IS KNOW TO BE NON HAZARDOUS INPUT AND OUTPUT I O WIRING MUST BE IN ACCORDANCE WITH CLASS I DIV 2...

Page 5: ...of the available cables WARNING Do NOT use a standard DH 485 cable to connect this port to Allen Bradley equipment PORT 3 ETHERNET CONNECTION RS232 RS485 5 EXPANSION 24VDC 10 USB PG TxA PIN 8 GREEN YELLOW LED LED AMBER NIC ETHERNET RS232 PORT COMMS COMMS PORT COMM CTS PIN 1 COMM Rx Tx RTS PIN 6 TxB COMM RxA RxB TxA TxB PIN 1 TxEN RS485 ETHERNET RS232 RS485 CF RS232 PG PORT RTS PIN 6 CTS PIN 1 USB ...

Page 6: ...USB port Once the driver is installed connect the Data Station to your PC with a USB cable and follow Mounting the CompactFlash instructions in the Crimson 2 0 user manual Note that using the USB port for frequent data transfers is not recommended For frequent data transfers it is recommended that the Ethernet connection be used Through the Ethernet connection a web page can be set up to view logg...

Page 7: ...0 and expansion slot DSPSX000 Data Station with multiple protocol converter data logger web server with Virtual HMI up to QVGA 320 x 240 expansion slot and extended operating temperature DSPSX001 Data Station with multiple protocol converter data logger web server with Virtual HMI up to VGA 640 x 480 size and expansion slot with increased SDRAM DSPGT000 Data Station with multiple protocol converte...

Page 8: ...h Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warranties expressed or implied are created with respect to The Company s products except those...

Reviews: