Primis Relay Bridge

  Elevator Control

 

Installation Guide

PART NUMBERS

FR-50-40-E, FR-50-40-EL

FR-50-24-E

PHYSICAL SPECIFICATIONS

Length

277 mm (10.91 in.)

Width

165 mm (6.50 in.)

Height

24 mm (0.94 in.)

Weight

564 g (19.89 oz.)

Max Readers

(each reader requires a FR-50-40-W485 adapter)

Max Input

0

Max Output

24

Electrical:

 UL294 and UL294B 

EMI Radiation:

 FCC Part 15 Class B

SUMMARIZED LEVELS OF  

ACCESS CONTROL COMPONENTS

Destructive Attack

Level I

Line Security

Level I

Endurance

Level I

Standby Power

Level I

Single Point Locking

Level I

The RS-485 input on the FR-50-40-E is intended for use in elevator cabs.

Two wire shielded cable running inside the travelling cable to the 
elevator cab is connected to the RS-485 inputs on the FR-50-40-E Primis 
Bridge and then connected to a FR-50-40-W485 (Wiegand to 485 
adapter) in the cab. 

A Wiegand output reader can then be connected to the inputs on the 
FR-50-40-W485 adapter. Up to two reader adapters can be connected to 
the RS-485 inputs on the FR-50-40-E.

The shield wire should only be connected at the RS-485 input on 
the FR-50-40-E.

READER INSTALLATION REQUIREMENTS

Primis Bridges should only be installed in dry, non-condensing 
environments. The ambient temperature of the environment should 
range between -40°C and 50°C.      

Primis Encryption Bridges should only be mounted to non-conductive 
surfaces. Incorrect mounting may short-circuit the electronics, which will 
cause it to malfunction.

INSTALLATION REQUIREMENTS

1. 

Wire any output devices to the Relay Outputs shown on the wiring 
reference on the back.

2. 

Supply power to the Primis Bridge using 12 - 16 Vdc & 1500 
mA (1500 mA internal; ~60.4 mA per relay) DC power connected 
directly to the Power In terminal on the Primis Bridge.

3. 

Connect a Cat5e or Cat6 cable from any port on an Ethernet 
switch to the RJ-45 connector on the Primis Bridge. Ensure 
that the length of the cable between the switch to the Primis 
Bridge is 100m or less. Greater lengths can be achieved by adding 
switches or repeaters every 100m.

4. 

INSTALLATION PROCEDURE

the Primis Bridge circuit board indicates 
that the bridge is powered but not 
connected to a server.  

A solid green “Ready” LED light indicates 
that the Primis Bridge has established a 
connection to the server and is ready to use.

To configure and add the Primis Bridge to a MESH/Primis
Server, refer to the MESH/Primis Solution Guide manual. the
RJ-45 connector on the Primis Bridge. 

Note

: Ethernet only

supports a maximum cable length of 100 m.

DC power, reader, and output device wires should be between 16-28 
AWG. They should also be stripped 5.5mm to sufficiently fit the terminal 
blocks and ensure that they do not come in contact with each other.