background image

+

+

A7202AA  

bar shower 

mixer without shower kit

A7207AA  

bath shower 

mixer without shower kit

A7698AA

 bath shower mixer 

pack with 600 rail & Hand spray

A7205AA

 bar shower mixer 

pack with 600 rail & Hand spray

A7215AA & A861383AA 

wrap over shower shelves

A7209AA  

bar

shower mixer dual 

pack with overhead 

Rain shower & Hand 

spray

Thermostatic, exposed, two hole, rim 

& wall mounted bath /shower mixers

Ceratherm T25

INSTALLER:

  

After installation please pass this instruction booklet to user

IMPORTANT

BEFORE CONNECTION, FLUSH WATER THROUGH PIPEWORK TO REMOVE

ALL DEBRIS ETC. WHICH COULD DAMAGE THE VALVE MECHANISM

INSTALLATION

INSTRUCTIONS

Summary of Contents for Ceratherm T25

Page 1: ...A861383AA wrap over shower shelves A7209AA bar shower mixer dual pack with overhead Rain shower Hand spray Thermostatic exposed two hole rim wall mounted bath shower mixers Ceratherm T25 INSTALLER Af...

Page 2: ...R PACK INSTALLATION A7209AA 15 8 OPERATING PRODUCT 16 9 TEMPERATURE ADJUSTMENT 18 10 COMMISSIONING PERIODIC CHECKS 19 11 FREQUENCY OF REGULAR SERVICING 19 12 COLD WATER ISOLATION CWI TEST 20 13 MAINTE...

Page 3: ...r sup plied without shower kit Dimensions same for A7205AA bar shower mixer pack with 600 rail Hand spray shower kit shown on next page Dimensions same for A7209AA bar shower mixer dual pack with over...

Page 4: ...Rain shower Hand spray supplied only with this product 4 Dimensions are in millimetres may vary within permitted tolerances 1 3 SHOWER PACKS Note The following two products do not include a shower pa...

Page 5: ...set with 80 hand spray 600 rail 1250 hose pair of mounting brackets sliding bracket for rail hose retaining ring Shower mixer dual pack with overhead Rain shower Hand spray supplied with A7209AA Inclu...

Page 6: ...s supplied without a shower kit A7698AA with supplied with the 600 riser rail handset pack 6 2 2 Deck mount mixer A7207AA A7698AA NOTE Shower kits have to be carefully assembled during installation ch...

Page 7: ...d as the vertical distance between the bottom of the cold water storage tank which feeds the hot water system and the highest point on the shower spray plate When installing with a shower pump the use...

Page 8: ...ervice valves for isolating both water supplies MUST be fitted below the bath to permit future maintenance of this product see sect 24 These should be fitted as close as practicable to the water suppl...

Page 9: ...ted zone of backflow risk for restrained hose which is longer than system design hose not permitted zone of backflow risk for unrestrained hose zone of backflow risk for restrained hose w c spill over...

Page 10: ...racticable to the water supply inlets of the mixer in an easily accessible location NOTE service valves are not supplied with thiese products see section 24 Shower Kit The flexible shower hose from th...

Page 11: ...pper supply pipes should be run within the wall cavity Hot supply pipe should be on the left hand side and the cold on the right Ensure that the hot and cold pipes are positioned 150mm apart and are l...

Page 12: ...etrically opposed Drill carefully to avoid damaging conce aled pipework 4 5 3 2 Apply a smear of silicone sealant to the rear of the assembled brackets and push them over the pipework Screw both brack...

Page 13: ...ewing them onto the adaptors until they are flush with the wall The covers only need to be hand tight Note Ceratherm T25 range is supplied with conical wall escutcheons Other T ranges have cylindrical...

Page 14: ...he tails of the legs into the two holes in the bath Align the legs and gently lower the mixer onto the rim of the bath IMPORTANT make sure the deck seals are still correctly located in the recesses of...

Page 15: ...view of overhead shower pack installation A7209AA 1 11 4 6 8 7 6 5 2 5 9 2 5 3 2 1 10 10 11 min 10 Nm min 700 Fittings grease Graisse de robinetterie Grasso per rubinetti Kraanvet Grasa de griferia Ar...

Page 16: ...nter economy flow stop delivering about 50 of the maximum flow rate achievable through this product To obtain greater flow rate press hold the right button rotate this handle further downwards The han...

Page 17: ...ther to the maximum flow stop Rotating this handle upwards from the parked position commences water flow will direct water to the top outlet This will activate the large overhead shower plate At each...

Page 18: ...section 16 steps 1 to 3 3 Before sliding the handle off ensure the dot on the handle is inline with the 40 marker on the mixer 4 Slide the handle off the spindle 5 Turn on the mixer position a thermom...

Page 19: ...low 45 C If there is no significant change to the set outlet temperature 2 C or less change from the original settings and the fail safe shut off is functioning then the valve is working correctly and...

Page 20: ...clean all filters ensure check valves are working and make sure all isolating valves are fully open Refit the shower handset to the flexible hose upon completion of the test NOTE In order to isolate t...

Page 21: ...se inline service valves if fitted 2 Fully open the flow or diverter handle to confirm water is switched off Unscrew the shower hose from the underside of the mixer This will permit some of the trappe...

Page 22: ...ly dependent upon the water quality and service life As a minimum we recommend removal both handles thermostatic cartridge flow control or diverter cartridge Cleaning the cartridge strainer screens is...

Page 23: ...small notch in the handle then use a sharp blade to lever the cap out taking care not to damage the chromed surfaces 2 Undo the handle retaining screw using a Phillips screw driver 3 Carefully slide...

Page 24: ...idge with a new one Alternatively if the cartridge is functioning correctly clean it thoroughly reuse it 5 When fitting the cartridge into the bore ensure the lug on the cartidge is orientated into th...

Page 25: ...ve insert then Align the dot marker on the handle with the line marker on the stop sleeve Reverse the sequence to refit the handle 18 DIVERTER REPLACEMENT 1 Observe disassembling sequence as detailed...

Page 26: ...the mixer bore screw the cartridge into the mixer body by hand then tighten with a spanner or socket Ideally torque to 16Nm min to 18Nm max 6 Refit the stop ring as illustrated above Align the marked...

Page 27: ...strainers from inside the mixer s inlet bores keep them in a safe location On a regular basis the anti splash nozzle on the bath mixer should be inspected and cleaned if necessary In areas where lime...

Page 28: ...replace the diverter cartridge 1 Remove the shower hose from the shower outlet 2 Unscrew the diverter knob on the top of the bath spout lift off 3 Use an 18mm spanner on the two flats on the shower ou...

Page 29: ...Non return valve A 861 372 NU 1 Set 7 Escutcheon A 960 914 AA 1 pcs 8 Shower bracket connect A 861 504 AA 2 pcs 9 Shower hose 1250 mm BE 125 AA 1 pcs 10 Handspray 3Func 80 B 9401 AA 1 pcs 11 Slider h...

Page 30: ...on nipple cpl A 861 381 NU 1 Set 23 2 A7207AA A7698AA A7207AA Bath Shower mixer w o shower kit A7698AA Bath Shower mixer with shower kit NOTE shower kit supplied with A7698AA is shown on the previous...

Page 31: ...ple cpl A 861 385 NU 1 Set 10 Shower hose 1750 mm BE 175 AA 1 pcs Exposed Thermostatic Bar Shower Mixer with overhead Rain shower Hand spray 11 Handspray 100 3F 8l min B 9403 AA 1 pcs 12 Shower bar 11...

Page 32: ...installed in an easily accessible location Basic valve with isolating only feature is available un der spares code S9005AA 15mm compression fittings at both ends plated finish E960086NU Brass valve wi...

Reviews: