Page 2: ...ucting parts Do not bring plug contacts in contact with pointed and metal objects Use in intended environments only Operate the device using a power unit meeting the specifications of the type plate only Keep the device power unit away from humidity liquid vapour and dust Do not modify the device Do not connect the device during thunderstorms Approach specialist retailers if you require repairs 2 ...

Page 3: ...ice prior to cleaning Aggressive or intense cleaning agents and solvents are unsuitable Make sure there is no residual moisture after cleaning We recommend cleaning devices using a dry anti static cloth 7 Disposing of the device Environmental pollution unsuitable for recycling Potential environmental pollution caused by components recycling circle interrupted This icon on product and packaging ind...

Page 4: ...ntakt mit Spannungsführenden Komponenten vermeiden Steckkontakte nicht mit spitzen und metallischen Gegenständen berühren Verwendung nur in dafür vorgesehenen Umgebungen Gerät ausschließlich mit Typenschildkonformen Netzteil betreiben Gerät Netzteil fern von Feuchtigkeit Flüssigkeit Dampf und Staub halten Eigenständige Modifikationen sind unzulässig Gerät nicht während eines Gewitters anschließen ...

Page 5: ...ußer Betrieb nehmen aggressive bzw scharfe Reinigungs und Lösungsmittel sind ungeeignet nach der Reinigung sicherstellen dass keine Restfeuchtigkeit vorhanden ist Reinigung der Geräte am besten mit trockenem Antistatiktuch durchführen 7 Entsorgung des Gerätes Umweltverschmutzung Wiederverwertung nicht möglich Mögliche Umweltbelastung durch Bestandteile Recyclingkreislauf unterbrochen Dieses auf de...

Page 6: ...gen 5 Drive installation Laufwerksinstallation 6 Starting up Inbetriebnahme Manual IB 246FP C3 EN 1 Blue LED glows when power on and blink when in the data access mode 2 Green LED glows when the drive is unlocked 3 Red LED blinks when the fingerprint or operation is incorrectly 4 Fingerprint sensor 5 USB 3 0 Type C Port 6 Lid DE 1 Blaue LED leuchtet bei Stromzufuhr blinkt bei Zugriff auf den Daten...

Page 7: ...ain features Fingerprint encryption with AES 256 bit Up to 8 different fingerprints USB 3 0 Type C with up to 5 Gbit s Made of high grade aluminum Supports 2 5 drives with up to 9 5 mm height Toolless drive installation 3 Package content 1x IB 246FP C3 2x USB 3 0 cable 1x Manual 4 System requirements One free USB 3 0 Type C port on your host computer Manual IB 246FP C3 ...

Page 8: ...n which direction 2 Install your drive by plugging it into the SATA connector at an angle of about 30 degrees and then gently pushing it down 3 Put the lid back on and close it again A small haptic feedback will show you that the lid is locked in place Manual IB 246FP C3 ...

Page 9: ... to the enclosure Then connect the enclosure to your Windows host computer After the USB device is detected by Windows a CD drive named ICY BOX FPTool will be displayed in This PC Click it A exe file named FPTool_Windows is displayed on this CD drive Please run this file Starting up with MacOS Connect the USB 3 0 cable to the enclosure Then connect the enclosure to your MacOS host computer After t...

Page 10: ...he ICY BOX FPTool the ICY BOX FPTool can be found by Applications Run the ICY BOX FPTool The FPTool gets started The configuration tool is started 1 Setting up your fingerprints 2 Administrator password configuration 3 Unlock via administrator password reset to factory settings all data will be lost Manual IB 246FP C3 1 2 3 ...

Page 11: ...66666 Confirm the entry with OK ATTENTION We urgently recommend to change the administrator password in order to guarantee security See point 6 4 6 2 To configure a new fingerprint click on the circled plus icon 1 1 Now touch the fingerprint sensor in different positions with the desired finger The software will show you when the fingerprint is 100 scanned Manual IB 246FP C3 1 1 1 2 1 3 1 4 ...

Page 12: ... fingerprints 6 3 To be able to use the HDD you must initialize it in Disk Management To do this right click on the HDD left side A and select Disk initialization Select the partition style GPT and confirm with OK Then right click on the HDD right side B to create a New Simple Volume Click through the settings with Next and adjust them according to your wishes Now the HDD is initialized and petiti...

Page 13: ...assword We do not recommend using birth dates or names Confirm the entry of your new password with OK 2 1 Enter old admin password 2 2 Enter new admin password 2 3 re enter new admin password 6 5 If you want to unlock the enclosure without the fingerprint you can use the FPTool and the administrator password To do this click on Disk 3 On the FPTool start page Click Unlock the Disk 3 1 to unlock th...

Page 14: ...ults click on Disk 3 and then on Restore to the default 4 1 ATTENTION If you restore the enclosure to factory defaults all data on the drive will be lost Please back up your data before restoring to factory defaults Confirm the process with OK Manual IB 246FP C3 ...

Page 15: ...2 Hauptmerkmale Fingerabdruck Verschlüsselung mit AES 256 Bit Bis zu 8 verschiedene Fingerabdrücke USB 3 0 Type C mit bis zu 5 Gbit s Aus hochwertigem Aluminium gefertigt Unterstützt 2 5 Laufwerke mit bis zu 9 5 mm Bauhöhe Werkzeuglose Laufwerksmontage 3 Verpackungsinhalt 1x IB 246FP C3 2x USB 3 0 Kabel 1x Handbuch 4 Systemanforderungen Ein freier USB 3 0 Type C Anschluss an ihrem Hostcomputer Han...

Page 16: ...tallieren Sie Ihren Datenträger indem Sie ihn in einem Winkel von ca 30 grad auf dem SATA Anschluss aufstecken und anschließend vorsichtig herunter drücken 3 Legen Sie nun den Deckel auf und schieben Sie diesen nun wieder zu Ein kleines haptischen Feedback lässt Sie erkennen dass der Deckel eingerastet ist Handbuch IB 246FP C3 ...

Page 17: ...l an das Gehäuse an Schließen Sie anschließend das Gehäuse an Ihren Windows Hostcomputer an Nachdem das USB Gerät von Windows erkannt wurde wird in Dieser PC ein CD Laufwerk mit dem Namen ICY BOX FPTool angezeigt Klicken sie darauf Auf diesem CD Laufwerk wird eine exe Datei mit dem Namen FPTool_Windows angezeigt Diese führen Sie bitte aus Inbetriebnahme unter MacOS Schließen Sie eines der beiden U...

Page 18: ... ICY BOX FPTool installiert ist wird es unter Programme angezeigt Führen Sie das ICY BOX FPTool aus Das FPTool wird gestartet 1 Einrichten Ihrer Fingerabdrücke 2 Administrator Passwort Konfiguration 3 Entsperren per Administrator Passwort Auf Werkseinstellungen zurücksetzen Alle Daten gehen dabei verloren Handbuch IB 246FP C3 1 2 3 ...

Page 19: ...Wir empfehlen ausdrücklich das Administrator Passwort zu ändern um die Sicherheit gewährleisten zu können Siehe dazu Punkt 6 4 6 2 Um einen neuen Fingerabdruck zu konfigurieren klicken Sie auf das eingekreiste Plus Symbol 1 1 Berühren Sie nun mit dem gewünschten Finger den Fingerabdrucksensor in verschiedenen Positionen Die Software zeigt Ihnen an wann der Fingerabdruck zu 100 eingescannt ist Hand...

Page 20: ...te nun verwenden zu können müssen Sie diese in der Datenträgerverwaltung initialisieren Dazu klicken sie mit einem Rechtsklick links A auf den Datenträger und wählen Datenträgeriniti alisierung aus Wählen Sie den Partitionsstil GPT aus und bestätigen Sie mit OK Anschließend können Sie mit einem Rechtsklick rechts B auf den Datenträger ein Neues einfaches Volumen erstellen Klicken Sie sich mit Weit...

Page 21: ...aten oder Namen zu verwenden Bestätigen Sie die Eingabe ihres neuen Passworts mit OK 2 1 Eingabe altes Administrator Passwort 2 2 Eingabe neues Administrator Passwort 2 3 Eingabe neues Administrator Passwort zur Bestätigung 6 5 Wenn Sie das Gehäuse ohne den Fingerabdruck entsperren wollen können Sie dies mit Hilfe des FPTools und dem Administrator Passwort tun Klicken Sie hierfür auf Disk 3 Auf de...

Page 22: ...auf Disk 3 und anschließend auf Restore to the default 4 1 ACHTUNG Wenn Sie das Gehäuse auf Werkseinstellungen zurück setzen gehen alle Daten auf dem Laufwerk verloren Bitte Sichern Sie Ihre Daten bevor Sie auf Werkseinstellungen zurücksetzen Bestätigen Sie die Aktion mit OK Handbuch IB 246FP C3 ...

Page 23: ...ithout prior notice The diagrams contained in this manual may also not fully represent the product that you are using and are there for illustration purposes only RaidSonic Technology GmbH assumes no responsibility for any differences between the product mentioned in this manual and the product you may have Microsoft Windows and the Windows logo are registered trademarks of Microsoft Corporation A...