Crowded data centers and racks filled to capacity with storage devices, monitors, servers communications devices, and other
equipment are driving the need for uninterruptible power with increased power density and power efficiency. The HP 3 Phase
Uninterruptible Power Systems provide just that. These rack-mountable Uninterruptible Power Systems provide up to 12,000 watts
(W) of power in a 6-U rack form factor. This equates to 2 KW per U space, which leads the industry in power density. The UPS
R8000/3 and the R12000/3 use digital signal processing and a new On-line On Demand hybrid technology to answer the
demands for increased power density and power efficiency.

On-line On Demand combines the efficiency of a line interactive UPS, up to 97%, with the stability of a double conversion on-line
UPS when power fluctuates beyond acceptable limits. Hot swappable batteries and electronics modules and an automatic bypass
reduce MTTR (mean time to repair) – down time in the event service is needed.
 

UPS R8000/3 and R12000/3 front view

UPS R8000/3 and R12000/3 front view

UPS R8000/3 and R12000/3 front view

UPS R8000/3 and R12000/3 front view

UPS R8000/3 and R12000/3 rear view

UPS R8000/3 and R12000/3 rear view

UPS R8000/3 and R12000/3 rear view

UPS R8000/3 and R12000/3 rear view

1. Battery compartment (behind bezel)

1. Communications terminal block

2. Menu navigation buttons

2. Output circuit breaker

3. Status and alarm LED display

3. Input circuit breaker

4. Electronics module compartment (behind bezel)

4. Battery circuit breaker

   

5. Input/output location R8000/3, input location R12000/3 1

   

6. ERM connector

   

7. Option card slots

   

8. Output connector R12000/3

   

9. Ground bonding screw

   

10. DB9 Service port

   

11. REPO port

Models

Models

Models

Models

HP R8000/3

HP R8000/3

HP R8000/3

HP R8000/3

HP R8000/3 8000kVA Three Phase 6U Rackmount Uninterruptible Power System

AF431A

HP R12000/3

HP R12000/3

HP R12000/3

HP R12000/3

HP R12000/3 12000VA Three Phase 6U Rackmount Uninterruptible Power System

AF429A

QuickSpecs

HP Rackmountable 3 Phase Uninterruptible Power

HP Rackmountable 3 Phase Uninterruptible Power

HP Rackmountable 3 Phase Uninterruptible Power

HP Rackmountable 3 Phase Uninterruptible Power

Systems

Systems

Systems

Systems

Overview

DA - 12857   North America — Version 8 — June 20, 2011

Page 1

Summary of Contents for R8000/3

Page 1: ... and R12000 3 front view UPS R8000 3 and R12000 3 front view UPS R8000 3 and R12000 3 front view UPS R8000 3 and R12000 3 rear view UPS R8000 3 and R12000 3 rear view UPS R8000 3 and R12000 3 rear view UPS R8000 3 and R12000 3 rear view 1 Battery compartment behind bezel 1 Communications terminal block 2 Menu navigation buttons 2 Output circuit breaker 3 Status and alarm LED display 3 Input circui...

Page 2: ...tic bypass feature ensures continuous power to your connected load even while the modules are being replaced Ease of maintenance and serviceability Faster time to repair MTTR Automatic and manual bypass Increased flexibility through modular design Increase battery back up Increase battery back up Increase battery back up Increase battery back up time with up to four time with up to four time with ...

Page 3: ...Pack and packaged services are also available for purchase You can choose the precise level of support based on your needs from basic to business critical Pre Failure Battery Warning and its associated Warranty The Pre Failure Battery Warning is proactively detected and notified by a LED indicator light showing that the battery needs to be replaced This notice is given 30 days prior to the battery...

Page 4: ... hps carepack NOTE NOTE NOTE NOTE For more complete information on HP Services offerings customers and resellers please visit us at http www hp com hps NOTE NOTE NOTE NOTE Additional information regarding worldwide limited warranty and technical support is available at http h18004 www1 hp com products servers platforms warranty index html NOTE NOTE NOTE NOTE The information contained herein is sub...

Page 5: ...NOTE NOTE NOTE NOTE For more information on the PDU Management Module please see http h18004 www1 hp com products servers proliantstorage powerprotection pdu html AF400A PDU Extension Bars PDU Extension Bars PDU Extension Bars PDU Extension Bars PDU options HP Two C13 PDU Extension Bars NOTE NOTE NOTE NOTE Each extension bar has a C 20 input cord and 7 x C 13 receptacles AF500A HP Fixed Cord Exten...

Page 6: ...ciency Efficiency Efficiency Efficiency 97 40 100 load 97 40 100 load Input connector Input connector Input connector Input connector NEMA L21 30 30A IEC309 560P9 60A Operating Temperature Operating Temperature Operating Temperature Operating Temperature Operating Temperature Operating Temperature Operating Temperature Operating Temperature 50 F to 104 F 10 C to 40 C Optimal battery Optimal batter...

Page 7: ...OTE NOTE Backup times are estimated for typical applications Actual performance will depend on load and battery conditions Environment friendly Environment friendly Environment friendly Environment friendly Products and Approach Products and Approach Products and Approach Products and Approach End of life Management End of life Management End of life Management End of life Management and Recycling...