5SC 1 - 3 KVA US_EN

5SC 1000i Rack2U
5SC 1500i Rack2U

5SC 2200i RT2U
5SC 3000i RT2U

Installation and
user manual

Summary of Contents for 5SC 1000i Rack2U

Page 1: ...ENGLISH Copyright 2016 EATON All rights reserved 5SC 1 3 KVA US_EN 5SC 1000i Rack2U 5SC 1500i Rack2U 5SC 2200i RT2U 5SC 3000i RT2U Installation and user manual ...

Page 2: ...Page 2 5SC 1 3 KVA US_EN ...

Page 3: ...lity eaton com Class B emission level CISPR 22 EN 55022 Harmonics emission IEC 61000 3 2 Flickers emission IEC 61000 3 3 Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information RISK OF ELECTRIC SHOCK Observe the warning associated with the risk of electric shock symbol Important instructions that must always be followed Do not disc...

Page 4: ...em can be disconnected from the AC power source by opening this circuit breaker or unplugging the input cable Check that the indications on the rating plate correspond to your AC powered system and to the actual electrical consumption of all the equipment to be connected to the system For PLUGGABLE EQUIPMENT the socket outlet shall be installed near the equipment and shall be easily accessible Nev...

Page 5: ...10 3 2 Installation of tower models 11 3 3 Installation of rack models 11 3 4 Wall mounting of rack models 13 3 5 Communication ports 14 3 6 UPS remote control functions 15 4 Operation 16 4 1 Start up and Normal operation 16 4 2 Starting the UPS on Battery 16 4 3 UPS Shutdown 16 4 4 Operation on Battery Power 16 4 5 Return of AC Input Power 16 5 Maintenance 17 5 1 Troubleshooting 17 5 2 Battery mo...

Page 6: ...ses over 50 of recycled cardboard Sacks and bags are made of polyethylene Packing materials are recyclable and bear the appropriate identification symbol 01 PET Materials Abbreviations Number in 01 PET the symbols Polyethylene terephthalat PET 01 High density polyethylene HDPE 02 Polyvinyl chloride PVC 03 Low density polyethylene LDPE 04 Polypropylene PP 05 Polystyrene PS 06 Follow all local regul...

Page 7: ...nly for 5SC 2200i RT2U and 5SC 3000i RT2U models D H W Description Weights kg lb Dimensions mm inch D x W x H 5SC 1000i Rack2U 15 0 33 0 405 440 86 2 15 9 17 3 3 4 5SC 1500i Rack2U 17 8 39 2 405 440 86 2 15 9 17 3 3 4 5SC 2200i RT2U 26 5 58 3 522 440 86 2 20 6 17 3 3 4 5SC 3000i RT2U 35 3 77 7 647 440 86 2 25 5 17 3 3 4 ...

Page 8: ...0i RT2U 2 6 3 1 5 4 5SC 3000i RT2U 2 6 3 1 5 4 1 Socket for connection to AC power source 2 Slot for optional communication card 3 Outlets for connection of equipment 4 RS232 communication port 5 USB communication port 6 Connector for ROO Remote ON OFF or RPO Remote Power Off control 2 Presentation ...

Page 9: ...de 13 Internal fault 14 Output load level 15 Battery level 16 Input measurements 17 Output measurements 18 Measuring unit 2 5 UPS setting through the LCD Release scroll down button to select menu 5s 2s 2s 2s Output voltage Alarm Sensitivity 1 1 In low sensitivity mode Lo UPS will tolerate more fluctuations in power and will go on battery power less often If the connected load is sensitive to power...

Page 10: ...e 23 USB communication cable 24 2 connection cables for the protected equipment 25 Cable locking systems 26 2 supports for tower position 5SC 2200i RT2U and 3000i RT2U models only 27 Connection cable to AC power source 5SC 2200i RT2U and 3000i RT2U models only Packing materials must be disposed of in compliance with all local regulations concerning waste Recycling symbols are printed on the packin...

Page 11: ... for 5SC 2200i RT2U and 5SC 3000i RT2U models 3 3 Installation of rack models 5SC 1000i Rack2U and 5SC 1500i Rack2U models Follow steps 28 to 30 for model mounting on the rails Use provided screws on step 28 of installation Using a longer screw could present a safety risk 28 30 30 28 29 ...

Page 12: ...2U and 5SC 3000i RT2U models Follow steps 31 to 33 for model mounting on the rails Use provided screws on step 33 of installation Using a longer screw could present a safety risk 33 33 31 32 31 34 34 The rails and necessary hardware are supplied by EATON ...

Page 13: ...VA US_EN ENGLISH 3 Installation 3 4 Wall mounting of rack models Only for 5SC 1000i Rack2U and 5SC 1500i Rack2U Use provided screws on step 35 of installation Using a longer screw could present a safety risk 35 35 36 36 ...

Page 14: ...ent 25 mA max Power 1 2 W 1 Connect the RS232 22 or USB 23 communication cable to the serial or USB port on the computer equipment 2 Connect the other end of the communication cable 23 or 22 to the USB 5 or RJ45 4 communication port on the UPS The UPS can now communicate with EATON power management software It is not necessary to shut down the UPS before installing a communication card 1 Remove th...

Page 15: ... connector 6 after unscrewing the screws 3 Connect a normally closed volt free contact 60 V DC 30 V AC max 20 mA max 0 75 mm2 cable cross section between the two pins of connector 6 see diagram 6 Contact open UPS shutdown Contact closed UPS start up UPS connected to AC power and AC power is available Note The local ON OFF control using button overrides the remote control function 6 Contact open UP...

Page 16: ... UPS front panel display for active alarms Resolve any active alarms before continuing See Troubleshooting in section 5 1 4 3 UPS Shutdown To shut down the UPS Press the button on the front panel for three seconds The UPS starts to beep The UPS then transfers to Standby mode and the indicator turns off 4 4 Operation on Battery Power Transfer to battery power The connected devices continue to be su...

Page 17: ...ntact your service representative Battery fault The batteries in the UPS are disconnected Verify that all batteries are properly connected If error persists note the alarm message and the UPS serial number and then contact your service representative The end of battery life is reached Contact your service representative for battery replacement Fan fault The UPS has a fan fault Check that no object...

Page 18: ...e tools with an insulated handle A B A Remove the center panel B Remove the left hand side of the front panel C C Disconnect the battery module by separating the two connectors D D Remove the metal protection cover in front of the battery one screw E E Remove the battery module and replace it Mounting the new battery module Carry out the above instructions in reverse order To ensure safety and hig...

Page 19: ...o 65 Hz 60 Hz system Output on battery power Voltage 220 230 240 V 10 6 1 Frequency 50 60 Hz 0 1 Hz Battery sealed lead acid maintenance free 2 x 12 V 9 Ah 3 x 12 V 9 Ah 4 x 12 V 9 Ah 6 x 12 V 9 Ah Environment Operating temperature range 0 to 40 C 32 to 104 F Storage temperature range 15 to 50 C 5 to 122 F Relative humidity 20 to 90 without condensation Noise level 45 dBA 1 Adjustable to 220 230 2...

Page 20: ...ing This is a battery voltage level indicating that battery power is low and that the user must take action in light of the imminent break in the supply of power to the load Normal AC input The AC power line supplying the UPS under normal conditions Percent load Ratio of the power effectively drawn by the load to the maximum output of the UPS Personalisation It is possible to modify certain UPS pa...