background image

 

Oral Temp Digital Thermometer 

Oral Digital Thermometer 

USER MANUAL 

 

Model: GF-MT506 (Flexible tip and Waterproof) 

Certifications: CE0197 and ISO13485:2016 

 

 

 

Summary of Contents for GF-MT506

Page 1: ...Oral Temp Digital Thermometer Oral Digital Thermometer USER MANUAL Model GF MT506 Flexible tip and Waterproof Certifications CE0197 and ISO13485 2016 ...

Page 2: ...3 WARNINGS AND PRECAUTIONS 4 PRODUCT DESCRIPTION 5 INDICATIONS FOR USE 7 CARE AND CLEANING 8 ºC ºF CONVERSION 9 TO TURN OFF THE THERMOMETER 10 MEMORY RECALL 10 BATTERY REPLACEMENT 10 TEMPERATURE TAKING TIPS 11 WARRANTY AND AFTER SALE SERVICE 12 SPECIFICATIONS 13 ...

Page 3: ...th oral armpit axillary and rectum rectal NOTE This thermometer comes with a clear storage case which should be used to store the thermometer in a dry cool place at all times when not in use PACKAGE CONTENTS No Name Quantity 1 Digital Thermometer 1 2 Storage Case 1 3 Battery 1 5 V DC button LR41xSR41x UCC392 1 4 User Manual 1 PRODUCT STRUCTURE Numerical temperature displays on the Left side of the...

Page 4: ...ot water 6 Keep the thermometer away from direct exposure to the sun and keep it in a dust free dry area well ventilated place at a temperature between 10 C 50 F 40 C 104 F Do not use the thermometer in highhumidity environments 95 RH 7 Do not use the thermometer if there are signs of damage on the measuring sensor or on the instrument itself If damaged do not attempt to repair the instrument Plea...

Page 5: ...immediately when there is a temperature elevation and if you are taking temperature for whom are Over 60 years of age Fever may be blunted or even absent in elderly patients Having diabetes mellitus or a weakened immune system e g HIV positive cancer chemotherapy chronic steroid treatment splenectomy Bedridden e g nursing home patient stroke chronic illness A transplant patient e g liver heart lun...

Page 6: ...r doctor what type of thermometer you used to take your temperature and on what part ofthe body Also bear this in mind if you are diagnosingyourself Measurements Maximum thermometer measurement range 32 0 C to 42 9 C 90 0 F to 109 9 F Measurement accuracy 0 1 C 35 5 C 42 0 C 0 2 F 95 9 F 107 6 F Storage transportation temperature 0 2 C 20 C 55 C 0 4 F 4 F 131 F Storage transportation humidity 15 9...

Page 7: ... of the reading and breathe evenly through the nose 3 Press the power button once and let it go to begin the reading Approximately reading time is between 15 and 19 seconds 4 One the temperature has been constant within 0 1 C for 4 seconds the thermometer will beep four times 5 Remove the thermometer and record the reading IN THE ARMPIT AXILLARY Placing the thermometer in the armpit provides a mea...

Page 8: ...proximately reading time is between 9 and 11 seconds 3 One the temperature has been constant within 0 1 C for 4 seconds the thermometer will beep four times 4 Remove the thermometer and record the reading Contraindications Do not use the thermometer if the area is infected or lacerated CARE AND CLEANING Use an alcohol swab or cotton swab moistened with 70 alcohol to clean the thermometer body and ...

Page 9: ...hing ºF 4 Press and let go of the Calibration button once to complete the setting and turn the thermometer off To switch from ºF to ºC 1 With the screen blank press and hold the Calibration Button ON OFF button 2 Keep the button pressed down while the thermometer shows 188 88 ºF on your screen 3 Keep the button pressed down and the ºF on the top right corner will switch to ºF and display Lo or Hi ...

Page 10: ...conds before being over written with a new temperature record NOTE Do not hold button down for longer than 4 seconds or you will switch the ºC to ºF or vise versa BATTERY REPLACEMENT The battery is empty and needs to be replaced when the battery symbol appear on the right of the LCD display Remove the battery cover by sliding the orange lid locate on the top of the thermometer upwards Remove the o...

Page 11: ...influence ear temperatures including when an individual has been lying on one ear or the other had their ears covered been exposed to very hot or very cold temperatures or been recently swimming or bathing In these cases remove the individual from the situation and wait 20 minutes prior to taking atemperature Use the untreated ear if prescription ear drops or other ear medications have been placed...

Page 12: ...ce of fever iscritical When the user is learning how to use the thermometer for the first time until he she has familiarized himself herself with the instrument and obtains consistent readings WARRANTY AND AFTER SALE SERVICE The device is under warranty for 12 months from the date of purchase The batteries the packaging and any damage caused by improper use are not covered by this warranty Excludi...

Page 13: ...sit conditions Temperature 20 55 C Humidity 15 95 RH non condensing Atmospheric pressure 86 106 kPa Operational conditions Temperature 15 40 C Humidity 15 95 RH non condensing Atmospheric pressure 86 106 kPa Weight 11g Follow product disposal instruction for electronic devices dictated by your city state country The battery that is provided with this product complies with the requirements stated i...