background image

Pi-8

  

USER MANUAL

Summary of Contents for Pi-8

Page 1: ...Pi 8USER MANUAL ...

Page 2: ......

Page 3: ...EL WILL NOT SET WHEN YOU ENTER YOUR CODE 6 3 1 1 IS THE CODE CORRECT 6 3 1 2 IS THE READY LED ON 6 3 1 3 HAS THE ENGINEER S RESET CODE BEEN ENABLED 6 3 1 4 DOES THE SOUNDER ACTIVATE BEFORE YOU EXIT 6 3 1 5 IS THE TAMPER LED ON 6 4 HOW TO UNSET THE PANEL 7 5 PROBLEMS WHEN UNSETTING THE PANEL 7 5 1 THE SOUNDER ACTIVATES IMMEDIATELY UPON ENTRY 7 5 2 THE SOUNDER ACTIVATES BEFORE YOU GET TO THE KEYPAD ...

Page 4: ...M PART SET AT HOME CIRCUITS 11 11 2 3 HOW TO CANCEL A PART SET CIRCUIT 11 11 3 DELAYED ALARM CIRCUITS 12 11 3 1 HOW TO PROGRAM DELAYED ALARM CIRCUITS 12 11 3 2 HOW TO CANCEL A DELAYED ALARM CIRCUIT 12 11 4 ADDING OR CHANGING USER CODES 13 11 4 1 ENTERING NEW AND CHANGING OLD CODES 13 11 4 2 USER CODE TABLE 14 11 4 3 THE DURESS CODE USER CODE 16 14 12 EVENT LOG 15 13 TROUBLE CONDITIONS 16 14 TEST M...

Page 5: ...ains power is present The led flashes when the mains supply is disconnected and a battery is present The led goes off when no power is present mains or battery 1 1 4 CIRCUIT LEDs YELLOW There are 8 leds which display the status of each circuit CIRCUIT LED CONDITION CIRCUIT STATUS ON CIRCUIT IS BYPASSED FLASHING ON OFF CIRCUIT IS ALARMED OFF CIRCUIT IS CLEAR 1 2 THE KEYPAD BUZZER The keypad has an ...

Page 6: ...W TO SET THE PANEL The panel may be set into either of the following modes 1 FULL SET when leaving home 2 PART SET when remaining at home 2 1 FULL SET To FULL SET the panel 1 Verify that the READY led is on 2 Press the key and enter your 4 digit user code The default code is 1234 If you enter an incorrect value press the key and re enter your code If your installer has enabled the quick set featur...

Page 7: ... key for 2 seconds until the keypad beeps 3 The leds will extinguish and any PART SET circuits will be automatically bypassed 4 The panel is now PART SET Ensure that you only enter those circuits that are bypassed NOTE See section on how to program PART SET circuits and section on how to program DELAYED ALARM circuits It is important to set the entry exit circuit front door as a DELAYED ALARM circ...

Page 8: ...BEEN ENABLED If the engineer s reset code has been enabled the panel cannot be set again after an alarm condition has occurred until your installer has reactivated it 3 1 4 DOES THE SOUNDER ACTIVATE BEFORE YOU EXIT Either the exit time is too short ask your installer to increase the exit time or you have not left via an entry route avoid these circuits in future or if this is impractical have your...

Page 9: ...alarm memory may be cleared by pressing the key 5 PROBLEMS WHEN UNSETTING THE PANEL 5 1 THE SOUNDER ACTIVATES IMMEDIATELY UPON ENTRY Either you have not entered via the entry exit circuit or you have entered whilst the panel is PART SET Have the entry exit circuit programmed as a DELAYED ALARM circuit 5 2 THE SOUNDER ACTIVATES BEFORE YOU GET TO THE KEYPAD Either you have entered an alarm circuit o...

Page 10: ...ions by the installer for example Panic or 24hr Circuits These circuits cannot be bypassed 8 HOW TO UN BYPASS A CIRCUIT An active circuit is termed an UN BYPASSED circuit To UN BYPASS a circuit s 1 Press the key followed by the key number corresponding to the currently bypassed circuit If the circuit is clear at this point pressing only the key will un bypass 2 The circuit led will extinguish The ...

Page 11: ...f the audible panic option has been programmed then the sounder strobe and internal speaker if fitted will activate 10 2 FIRE ALARM F Holding down the F key on the keypad for 1 second activates a FIRE ALARM if programmed The sounder strobe and internal speaker if fitted will activate Fire alarms are always audible The alarm auxiliary output will be triggered 10 3 MEDICAL ALARM M Holding down the M...

Page 12: ... will be on constantly 4 To de select a circuit press the corresponding key again The circuit led will extinguish 5 Press the key to exit the chime programming mode If no key is pressed for 60 seconds the chime mode will be exited automatically Note To de select a chime circuit repeat the above steps and make sure that the circuit led is off 11 2 PROGRAMMING THE PART SET AT HOME MODE 11 2 1 PART S...

Page 13: ...l flash together 3 Walk through the areas that you will use when the panel is PART SET The PIR sensors will detect your movement and bypass these circuits automatically The PART SET circuits will be indicated by the corresponding circuit leds being on permanently 4 Press the key to exit this mode 11 2 3 HOW TO CANCEL A PART SET CIRCUIT It may become necessary to clear or de select a PART SET circu...

Page 14: ...sh together 3 Now select the circuits that you require to be DELAYED ALARM circuits by pressing the key corresponding to the circuit number The DELAYED ALARM circuits will be indicated by the corresponding circuit leds being on permanently Note Any PART SET circuits that have been programmed will be indicated by flashing circuit leds 4 Press the key to exit this mode 11 3 2 HOW TO CANCEL A DELAYED...

Page 15: ...The default master user code is 1234 5 The READY and TAMPER LEDs will now flash on and off together indicating that the correct master code was entered If the wrong code is entered the keypad will beep three times 6 Enter the number 1 to 16 of the user code which you wish to enter or change and press the key 7 Now enter the new code 4 digits and press the key The keypad will give a long beep to in...

Page 16: ...ation where an intruder forces a user to unset the panel under duress When the duress code is entered the control panel unsets normally however a DURESS REPORTING CODE is transmitted to the monitoring station to inform them that a user has been forced to unset the control panel by an intruder If a duress code is entered in the unset condition a DURESS REPORTING CODE is again transmitted however th...

Page 17: ...R LED flashing Panic POWER and TAMPER LEDs flashing Duress In addition to the above any circuit LEDs show which circuits were bypassed alarmed 3 Press the key to scroll back through the events 4 Press the key to exit this mode If the key is not pressed and there are no further key strokes this mode will timeout in 15 seconds Example 1 Ensure that the panel is not set 2 Hold down the 0 key for thre...

Page 18: ...EST MODE Hold down the 8 for 2 seconds key to enter this mode Only the Power LED will be lit While in the test mode the alarming of any circuit will cause the keypad and the internal speaker to beep Press the following keys to test the various aspects of the system KEY ACTION 1 Sounder test half a second 2 Keypad buzzer and speaker test 3 Strobe test short flash 4 Pulses all three auxiliary output...

Page 19: ......

Page 20: ...Part Number 320697 0A ...