Page 1: ...EN GSL TECHNOLOGY COMPANY LTD User Manual GSL5000U 15S 48V 4 8Kwh 16S 51 2V 5 12Kwh GSL7000U 15S 48V 7 2Kwh 16S 51 2V 7 68Kwh GSL10000U 15S 48V 9 6Kwh 16S 51 2V 10 24Kwh For On Off Hybrid Solar Storage System ...

Page 2: ...y 8 3 6 3 Functional Specifications 8 4 Safe handling guide 10 4 1 System Diagram 10 4 2 Tools 10 4 3 Safety Gear 11 5 Installation 11 5 1 Inventory of items 11 5 2 Installation Location 11 5 2 1 Minimum clearances 12 5 3 Installing the Battery Pack 13 5 3 1 Mounting to a wall 13 5 4 Parallel use of battery 14 5 4 1 Parallel use of battery All off grid solar inverters 14 5 4 2 Parallel use of GSL ...

Page 3: ... and packing list first if the battery is damaged or spare parts are missing Please contact the dealer Before installation be sure to cut off the grid power and make sure the battery is in the turned off mode Wiring must be correct do not mix connect the positive and negative cables and ensure no short circuit with the external device It is prohibited to connect the battery with AC power directly ...

Page 4: ... time 25 C 20 years Life cycles 80 DOD 25 C 6000 Cycles Storage time temperature 5 months 25 C 3 months 35 C 1 month 45 C Operation temperature 20 C to 60 C 60 25 Relative Humidity Storage temperature 0 C to 45 C 60 25 Relative Humidity Lithium Battery Standard IEC62619 UN38 3 ROHS CE EMC UL1642 MSDS Enclosure protection rating IP21 Electrical Parameters Operation voltage 48 Vdc 48 Vdc 48 Vdc Max ...

Page 5: ... years Life cycles 80 DOD 25 C 6000 Cycles Storage time temperature 5 months 25 C 3 months 35 C 1 month 45 C Operation temperature 20 C to 60 C 60 25 Relative Humidity Storage temperature 0 C to 45 C 60 25 Relative Humidity Lithium Battery Standard IEC62619 UN38 3 ROHS CE EMC UL1642 MSDS Enclosure protection rating IP21 Electrical Parameters Operation voltage 51 2 Vdc 51 2 Vdc 51 2 Vdc Max chargin...

Page 6: ...d convenient installation Integrated state of the art BMS to manage and monitor battery information including voltage current and temperature as well as balance cell charging discharging rates 5 10years warranty 3 2 Interface Introduction This section details the interface functions of front and back panel Front interface No Description Silk screen Remark 1 2 UES0600 P P Output terminal 3 4 UES060...

Page 7: ...y 15 Handle 16 Bracket 3 3 SOC Indicator Status Indicator Guides Chart 1 Battery Status Status Normal Warning Protection RUN ALM Capacity LED Description Shut Down Shut down OFF OFF OFF OFF OFF OFF All OFF Standby Normal Flash OFF OFF OFF OFF OFF Standby Charge Normal ON OFF Based on capacity Warning ON Flash Protection ON ON Discharge Normal ON OFF Based on capacity Warning ON Flash Protection OF...

Page 8: ...ator Canbus RS485 Active communication portal between battery and inverter USB To RS232 to get dynamic monitoring data of the battery from upper computer Address Reserved Address portal for multiple parallel connections 3 5 Wake Up button Battery On When battery is shut down press this RST button for 3 seconds It is activated when the LED lights flicker from RUN light to the lowest capacity indica...

Page 9: ... dormancy activated will show the welcome screen press the MENU button to enter the main menu page As shown in the figure below Battery parameters collection page When the cursor is point to Battery Parameters Acquisition press ENTER key will enter into the page of Battery Parameters Acquisition As shown in the figure below ...

Page 10: ...s page When the cursor is point to Battery Status press ENTER key will enter into the page of Battery Status As shown in the figure below Parameter Settings Screen can not set up parameters System Settings Page Baud Rate 9600 do not set ...

Page 11: ... menu page 4 In a dormant state press any key can activate the screen Dormancy shutdown Under normal operation condition with no keystrokes 1 minutes later system will enter a state of dormancy shutdown Shutdown dormancy state press any key screen can be activated 4 Safe handling guide 4 1 System Diagram 4 2 Tools The following tools are required to install the battery pack Wire cutter Crimping Mo...

Page 12: ... Wire M6 125A 1000V E Instruction manual Warranty Card 1 This document Option Parallel Power cable 1 0 M 2 125A 1000V Option Parallel com cable 1 0 M 1 RJ45 5 2 Installation Location Make sure that the installation location meets the following conditions The installation site must be suitable for the size and weight of the battery Must be installed on a firm surface to sustain the weight of batter...

Page 13: ...pack to operate is 0 C to 45 C Frequent exposure to harsh temperatures may deteriorate the performance and life of the battery pack 5 2 1 Minimum clearances Observe the minimum clearances to walls other batteries or objects as shown in the diagram and picture below in order to guarantee sufficient heat dissipation Direction Minimum clearance mm Above 300 Below 300 Sides 500 Front 300 ...

Page 14: ...he hole position 3 Drill 8 holes according to the hole position it is ø10 with depth 60mm 4 Hammer the M8 screws to the above holes and screw the nut Note Do not position screws flush to the wall leave 10 to 20 mm exposed 5 Fix the mounting frame to the 8 screws 6 Raise the battery a little higher than the mounting frame whilst maintaining the balance of the battery Hang the battery on the frame t...

Page 15: ...but we recommend 2 4 units according to application When connecting with off grid 48VDC solar inverters it does not need to add Canbus RS485 communication cables with inverters if inverter brand factory does not have Canbus RS485 port just plug and play use NOTE Parallel power cable standard is 1 meter This is not standard cable in battery package For parallel cable quantity needed please consult ...

Page 16: ...www gsl energy com 15 Three pcs connect diagram Four pcs connect diagram ...

Page 17: ...us 14units RS485 with GSL hybrid solar inverter but we recommend to use 2 4 units according to application The application needs power and communication connections as below choose suitable parallel power cables and related connectors NOTE Parallel power standard is 1 meter This is not standard cable in battery package For parallel cable issue please consult related factory sales manager for prope...

Page 18: ...45 On off Grid Wall mounted SOLIS RHI 3K 3 6K 5K 48ES CAN RJ45 On off Grid Wall mounted VICTRON Multiplus Quattro 48 CAN RJ45 On off Grid Wall mounted IMEON IMEON3 6 9 12 CAN RJ45 On off Grid Wall mounted INFINI Voltronic Axpert Infinisolar series 48V Axpert series 48V CAN RJ45 On off Grid Wall mounted SMA Sunny Island4 4M 6 0H 8 0H CAN RJ45 On off Grid Wall mounted SAJ ELECTRIC Sunfree 4K 5K seri...

Page 19: ...www gsl energy com 18 Canbus Version Max 15 PCS RS485 Version Max 14 pcs ...

Page 20: ...www gsl energy com 19 One pcs connect diagram ...

Page 21: ...www gsl energy com 20 Two pcs connect diagram ...

Page 22: ...www gsl energy com 21 Three pcs connect diagram ...

Page 23: ...www gsl energy com 22 Four pcs connect diagram ...

Page 24: ...www gsl energy com 23 15 14 pcs connect diagram ...

Page 25: ... commissioning Failure to observe the user manual quick installation instructions Incorrect usage or inappropriate operation Insufficient ventilation of the device Failure to observe the applicable safety regulations Force majeure Neither does it cover cosmetic defects which do not influence the energy production 6 5 Warranty conditions If the battery becomes defective during the agreed factory wa...

Page 26: ... to factory when you need to apply warranty service support Warranty Card User Information Company User Name Address Telephone Email Project installation location Product Information Battery Model Serial No Invoice Number Purchase Date Dealer Commission date Fault Error Description ...

Page 27: ... TECHNOLOGY COMPANY LTD No 11 Zhangbei Road Longgang District Shenzhen China 518172 Tel 0755 84515360 24 Hrs On line 0086 13923720280 Inquiry Email jimdeng gsl energy com After Sale Service info gsl energy com Website www gsl energy com ...