Page 1: ...I N T E R REMOTE CONTROLLED SWING GATE OPENER SW 400 UG 300 SWR 400 OWNERS MANUAL SERVICE BOOK ...

Page 2: ...ich are developed in India Hence we assure you trouble free operation and committed service at all time to come To ensure a long trouble free operation give proper care and maintenance as described in this manual We wish you the best out of this system INTERGLIDE AUTOCONTROLS All information in this manual is based on the latest product information available at the time of publication We are commi...

Page 3: ...ther than usual 2 Check the floor level and make sure that the gate should not rub on ground during opening closing We offer 3 types of operators for Swing Gates 1 Swing Gate Opener SW 400 2 Under Ground Opener UGS 300 3 Roller Swing gate Opener SWR 500 STANRARDS PACKINGS Arm Gate Motor 2 Nos Mounting Brackets 2 Sets Remote transmitter 2 Nos Close Hit bush 1 No Control Box with control Board 1 No ...

Page 4: ...truction is approximately 100Mtrs Release Keys This key is used to release the motor mechanism to the gate in case of any malfunction of the gate or during power failure Electro Magnetic Lock EM Lock This lock is attached to Gate with MOTOR 1 While closing this lock gets locked to the slot and while opening it gets released itself and open This acts like a tower bolt for added safety This lock can...

Page 5: ...sible 5 Places where KSEB power is not available or not easy to access there is provision for SOLAR POWERED SYSTEM SPECIFICATIONS SW300 UG 300 SW500 SWR 500 Input Power 220VAC 220VAC 220VAC 220VAC Battery Backup option 12V 7Ah 2 12V 7Ah 2 12V 7Ah 2 12V 7Ah 2 Nos DC Motor 24VDC 80W 24VDC 50 W 24VDC 100W 24VDC 50W Operating Time 10 to 12 Sec 10 to 12 Sec 10 to 12 Sec 10 to 12 Sec Operating speed Fas...

Page 6: ...ark Screw the Motor Arm to the LEAD Plate Extend the Motor Arm fully out Rotate Arm Extension ONE Turn clockwise Spot weld the Tip Clamp to the gate Connect both motors electrically to the control board Ensure that the Pillar is strong enough to mount the Motor Bracket Reverse that Motor connections in the control Board Both Gate Opens Any Gate Closes START 2S Keep the gate half way open engage ge...

Page 7: ...y without any obstacle 2 Hinges are stabe and in good condition Fix the rear support Clamp on the gate post If necessary please adjust the support length Selection of Opening Angle for SW 300 Opening Angle A in MM B in MM C in MM 90 degrees 145 145 130 Degrees 132 132 Eg INSTALLATION DIAGRAM Open angle 90 degrees ...

Page 8: ... Iron weld supporting clamps If Concrete use Anchor Bolts 1 Release the GEAR MOTOR ARM CLOSE both gates 2 Extend the Lever Arm fully outwards by rotating the Arm Extension 3 Rotate the Arm Extension one turn clockwise 4 Mount the Base bracket to the pilar corresponds to horizontal section of the gate using water level Fix with anchor bolt Attach Tail Plate with 2 bolts 5 Screw the Motor Arm to thi...

Page 9: ... waterproof cover on the Motor Arms and insert the release key and turn quarter turn clockwise This operation releases the gear from the motor and the gate can be manually moved Do this for the other gate also To LOCK insert the key and turn quarter turn anticlockwise ...

Page 10: ...oth leaves are blocked in the upper rubber part of the base Fix it firmly to ground Lock is screwed to a base plate which is to be welded to the gate tip Unlock EM Lock and place it in the tip Fig so that the lock lever just moves above the base Bottom It should locked into the base while closing and gets released while opening Manual release system Connections Give connection to Motor1 Motor 2 an...

Page 11: ... reached and cut off the respective motor power LOAD sensitivity of the motor can be set independently adjusted with PRESETS for each motor Clockwise turning will increase load It should be adjusted such that motor does not trip due to its inherent friction and load Try re adjusting the pre set and make sure that both gates work smoothly FAST WORKING TIME can be set for each motor independently us...

Page 12: ...lose delay time Auto close delay time 4 Delayed closing for Motor1 3 sec Delayed closing for Motor1 1 5 sec RF Remote Control Two Channels buttons provided A Open Close Open Dual Gate B Open Close Open Single gate Learning Remotes Press LEARN button on the Remote Receiver Board once Its LED lit Keep pressing a button on the RF Remote Receiver LED blinks 3 Times and is learnt Repeat for other remot...

Page 13: ...ion one turn clockwise 4 Mount the Base bracket to the pilar corresponds to horizontal section of the gate using water level Fix with anchor bolt Attach Tail Plate with 2 bolts 6 Screw the Motor Arm to this Tail Plate Then spot weld the END Clamp to the gate See that the Motor arm is horizontal 5 Ensure the gate can be opened and closed fully 6 Weld the End Clamp strong And install second motor li...

Page 14: ...Components 1 PWM SOLAR CONTROLLER 24V 10Amp 2 2 Nos of Solid Battery 12V 7AH connected in Series 3 2Nos of 12V 10W Solar Panel connected in Series Controller is set to factory default settings ...

Page 15: ...mal use During the warranty period INTERGLIDE shall as its option repair or replace any defective part product at your site free of any charge No claim for repair will be entertained unless the customer produces original OWNER s MANUAL Warranty is not applicable in situation where Unauthorized repair replacement has been carried out Shifting reinstallation of the system Damage due to mishandling o...

Page 16: ... battery connection and condition Call service 4 Any maintenance required No except keep the hinges clean and frequently lubricate 5 No Response from System This could be due to power battery failure or Machine damage Un clutch both Motor Arm as shown in picture above Release the EM Lock with the attached keys Slowly move both gates manually open Call for service Periodic Maintenance Keep EM Lock ...

Page 17: ... this group IN T E R INTERGLIDE AUTOCONTROLS 3 463A KADAYIRUPPU P O KOLENCHERRY ERNAKULAM 682311 KERALA E Mail info interglide in Website www interglide in WORKS 94 201 3rd Cross Sivaji street T Nagar Chennai 600 00 ...