GEIGER System INline GSI56.. E12 SMI

with electronic end stop for the facade technology

Summary of Contents for INline GSI56 Series

Page 1: ...d operating instructions Notice originale de montage et d utilisation Instrucciones originales de instalaci n y funcionamiento Istruzioni originali di installazione e funzionamento DE EN FR ES IT GEIG...

Page 2: ...uarantee In the case of incorrect installation contrary to the installation and operating instructions and or constructional modification the legal and contractual guarantee for property damage and pr...

Page 3: ...ower supply if opera tions such as for example window cleaning are being carried out in the vicinity f During operation observe the danger zone f Do not use the installation if people or objects are i...

Page 4: ...nd any other fixed element f The rated speed and the rated torque of the motor must be compatible with the device f The mounting accessories that are used must be designed in accordance with the selec...

Page 5: ...ement and the facade element must be checked on site during installation A centering bore optionally used for double walled profiles may not be larger than 0 3 mm compared to the centering collar Cavi...

Page 6: ...a locking switch is necessary no simultaneous UP and DOWN commands The operations with the service clamps may be accomplished only by an electrical specialist The number of motors which can be connec...

Page 7: ...yellow green wires STAS 4 STAK 4 Wire colour Name 1 2 3 4 5 PE black grey brown blue green yellow I I L N PE Cable connections and connector assignment for the STAS4 STAK4 connector system with cable...

Page 8: ...e Drive l PE l N L1 L1 L2 L3 l l l l l l Actuator Telegram operation N PE Drive l PE l N L2 Drive l PE l N L3 Drive l PE l N L1 L1 L2 L3 N PE Drive l PE l N L2 Drive l PE l N L3 Drive l PE l N L L N P...

Page 9: ...9 www geiger de EN EN 11 For your notes SMI KEY ID sticker Place of installation e g 1st floor left side third room 1st window etc...

Page 10: ...operation I If the factory setting has been carried out and if the programming mode is activated max 100 revolutions can be done downwards Reset to factory settings for a further run downwards 13 Act...

Page 11: ...ds 1 x after 6 seconds and 4 x after 10 seconds Then the motor is reset to factory settings Note the position at which the drive has been reset to the factory setting is now defined as the upper end p...

Page 12: ...ves 2006 42 EC 2014 30 EU 2014 53 EU 2011 65 EU EU 2015 863 EU 2017 2102 Applied standards DIN EN 60335 1 VDE 0700 1 2012 10 EN 60335 1 2012 DIN EN 60335 1 Ber 1 VDE 0700 1 Ber 1 2014 04 EN 60335 1 20...

Page 13: ...ge temperature Humidity T 15 C 70 C dry and non condensing place 1 With angel gear GSI1 total length 52 mm weight 0 4 kg Subject to technical modifications Please find information to the ambient tempe...

Page 14: ...14 Gerhard Geiger GmbH Co KG 100W2507 0220 V001 en EN EN...

Page 15: ...15 www geiger de EN EN...

Page 16: ...EN EN For technical questions please call our service team at 49 0 7142 938 333 They will be happy to assist you Gerhard Geiger GmbH Co KG Schleifm hle 6 D 74321 Bietigheim Bissingen T 49 0 7142 9380...