 Regulatory 

Notices 

EC Declaration of Conformity 

FarSite Communications Limited declare that the product FarLinX X25 Gateway is in conformity with the 
following standards and other documents: 
 
Telecommunications Terminal Equipment: TTE Directive 91/263/EEC, 

TBR1, TBR2

 

Electromagnetic compatibility: EMC Directive 2004/108/EC, 

EN55022, EN55024, EN61000-3-2, EN61000-3-3 

Safety: LVD Directive 2006/95/EC, 

IEC EN 60950

 

 

 

Federal Communications Commission (FCC) Statement 

 

Radio Frequency Interference (RFI) (FCC 15.105) 

 

The FarLinX X25 Gateway has been tested and found to comply with the limits for Class A digital devices pursuant to 
Part 15 Subpart A of the FCC Rules.  These limits are designed to provide reasonable protection against harmful 
interference in a commercial environment.  This equipment generates, uses, and can radiate radio frequency energy 
and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case 
the user will be required to correct the interference at his own expense. 
 

 

Labelling requirements (FCC 15.19) 

 

This device complies with Part 15 of FCC rules.  Operation is subject to the following two conditions: (1) this device 
may not cause harmful interference, and (2) this device must accept any interference received, including interference 
which may cause undesired operation. 
 

 

Modifications 

 

Changes or modifications to this equipment not expressly approved by FarSite may void the user’s authority to 
operate this equipment. 

 

FCC Declaration of Conformity 

(In accordance with FCC dockets 96-208 and 95-19) 

 

Manufacturer’s name: FarSite Communications Limited 

Tempus Business Centre, 60 Kingsclere Road, Basingstoke 
Hampshire, RG21 6XG, United Kingdom 

 

FarSite Communications Limited declares that the product FarLinX X25 Gateway to which this declaration relates, 
meet the requirements specified by the Federal Communications Commission as detailed in the following 
specifications 

 



Part 15, Subpart B, for Class A Equipment 



FCC Docket 96-208 as it applies to Class A Personal Computers and Peripherals 

 

The product has been tested at an external laboratory certified per FCC rules and has been found to meet the FCC, 
Part 15, Class A emission limits.  Documentation is on file and available from FarSite. 

 

Industry Canada 

 

This Class A digital apparatus meets the requirements of the Canadian Interference Causing Equipment regulations. 

 

Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le máteriel brouilleur du 
Canada. 

FarLinX X25 Gateway Quick Start Guide 

 

N0901M-01  V2.3.3 

www.farsite.com

 Page 

 

FarLinX X25 Gateway 

Q

UICK

 S

TART

 G

UIDE

 

Thank you for choosing the FarLinX X25 Gateway for your TCP to X.25 interworking needs.  The FarLinX X25 
Gateway is designed to enable X.25 network replacement while supporting legacy X.25 connected host and 
terminal equipment without modification.  It also permits XOT connected equipment access to X.25 connected 
hosts. 
 

 

Front Panel Guide 

 

 

 

READY 

indicates system status 

Green 
Red 
Flashing Red 

System OK 
System not ready for use  
System fault 

LAN 

indicates LAN status 

Green 
Flashing Green 
Flashing RED

 

LAN interface operational 
LAN data transfer activity 
LAN not operating correctly (includes no LAN cable) 

WAN 

indicates WAN status 

Green 
Flashing Green 
Red 
Flashing Red 
 
Amber

 

Configured X.25 interfaces operational 
WAN data transfer activity 
Some configured X.25 ports working correctly 
No configured X.25 ports operating correctly (this would 
include no cable attached) 
No X.25 ports started (or none configured) 