background image

- 1 -

STR-3 Pico

Miniature roller blind con-

troller for 230 V AC motors

The STR-3 Pico controller is designed to control roller blinds (

���

����

) or other objects (e.g. gates) that are driven with single-

-phase alternating current electric motor with momentary swi-

tch (eg. bell).

The controller can operate as a stand-alone device (for opening/

closing of a single roller blind), but it is also possible to combine 

controllers into groups to central control multiple roller blinds. 

The controller power supply is indicated by a green LED. Roller 

blind motor starts after momentary passing of the N signal to 

one of the control inputs. The motor activates for the user-pro-

grammed time that allows to fully lift or lower the roller blind. 

Roller blind can be stopped on the user-selected level (incomple-

te opening or closing of the roller blind).

Purpose

Functioning

F&F Filipowski L.P.

Konstantynowska 79/81, 95-200 Pabianice, POLAND

phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71

www.fif.com.pl; e-mail: [email protected]

Do not dispose of this device in the trash along with other waste!  

According to the 

Law on Waste, electro coming from households free of charge and can give any amo-

unt to up to that end point of collec� on, as well as to store the occasion of the pur-

chase of new equipment (in accordance with the principle of old-for-new, regardless 

of brand). Electro thrown in the trash or abandoned in nature, pose a threat to the 

environment and human health.

Summary of Contents for STR-3 Pico

Page 1: ...ts The motor activates for the user pro grammed time that allows to fully lift or lower the roller blind Roller blind can be stopped on the user selected level incomple te opening or closing of the ro...

Page 2: ...ready in motion causes the roll er blind to stop Long press 0 5 s switches on the roller blind for as long as the key is pressed Each time you press the key the roller blind will move in the di rectio...

Page 3: ...e only in the de sired direction Roller blind will stop only after a preset time or by pressing any of the local control keys If during the execution of one center control command another one is issue...

Page 4: ...sor is used or too strong wind if the additional STR W wind sensor is used is detected 1 Disconnect the power supply 2 Mount the controller on the rail in the distribution box 3 Connect the controller...

Page 5: ...ain The controller will save the elapsed time in non volatile memory and then exit the programming mode which is indi cated by the constant U LED light Test run 1 Place the blind in the outmost top or...

Page 6: ...the learn ing mode The controller is designed to measure time span shorter than 5 min Attempting to set the controller for longer span will result in exit from the learning mode The controller learni...

Page 7: ...7 Wiring diagram...

Page 8: ...al control direction 4 central control direction 5 central control direction 6 local control direction 7 motor power supply direction 8 motor power supply direction POWER LED indication of power and p...

Page 9: ...ightening torque 0 4 Nm local control terminal 2 DY 1 mm l 10 mm dimensions 35 36 19 mm mounting flush mounted box 60 protection level IP20 The application examples listed below can be downloaded from...

Page 10: ...declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaration...

Page 11: ......

Reviews: