background image

○ ○ ○ ○ ○

Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com

INSTALLATION & INSTRUCTION MANUAL

K1 Series

All-In-One 12-Pad

Summary of Contents for K1 Series

Page 1: ...Essex Electronics Inc 805 684 7601 800 KEY LESS fax 805 684 0232 keyless com INSTALLATION INSTRUCTION MANUAL K1 Series All In One 12 Pad...

Page 2: ...s contained in this documentation at any time Document Information IOMK1 Installation Operations Manual for the K1 Series All In One 12 Pad 3x4 and 2x6 October 2006 This documentation is also applica...

Page 3: ...s 2 Keypad Connector Diagram 3 Keypad Configuration 5 Self Contained Keyless Entry System 9 Self Contained Keyless Entry System Specifications 9 Self contained Keyless Entry System Configuration 10 Pr...

Page 4: ...Essex Electronics Inc 805 684 7601 800 KEY LESS fax 805 684 0232 keyless com iii...

Page 5: ...consists of either a 3x4 or 2x6 Keypad Input Voltage 5VDC or 12 to 24VDC Jumper Selectable Standby Current Draw 25mA Outputs 3 Open Collector 1 4 A Max to Ground Keypad Switch Life 1 Billion Cycles Ke...

Page 6: ...t Numbers 3x4 Keypad K1 34B Brass Finished Bezel K1 34S Stainless Steel Bezel K1 34K Black Bezel K1 34X No Bezel 2x6 Keypad K1 26B Brass Overlay K1 26I Illuminated K1 26S Stainless Steel Overlay K1 26...

Page 7: ...door is opened without a code or if the door is left open longer than the Door Ajar Time setting CONFIGURATION PINS CONFIG VOLTAGE SELECT Do NOT apply voltage 12 24V default Jumper on 1 pin only 5V Ju...

Page 8: ...Mode same as entering 3 Master Code GREEN Optional Encoded Relay Module GREEN is a special output for an optional Secure Encoded Relay Module Part No ERM 3 BROWN 24 hour Access If Time Clock is enabl...

Page 9: ...2 Jumper the two pins above the connector labeled CONFIG 3 Apply appropriate power You should hear 4 beeps and the RED LED will flash and the GREEN LED will be solid 4 Now that the Keypad is in confi...

Page 10: ...ash and the GREEN LED will be solid If you hear a long error beep re enter the configura tion number followed by 5 Remove power 6 Remove configuration jumper 7 Re apply power IMPORTANT Once the config...

Page 11: ...0099 The Keypad will beep twice and both LEDS will flash for approxi mately 10 seconds During this time the Keypad will appear dead Do NOT remove power 5 Once the reset is complete you will hear 4 be...

Page 12: ...l Operation 210 Off factory default Off factory default 211 Off Dim 212 Off Bright 213 Dim Dim 214 Dim Bright You should hear 3 beeps indicating successful configuration the RED LED will continue to f...

Page 13: ...DC Jumper Selectable Standby Current Draw 25mA Outputs 3 Open Collector 1 4 A Max to Ground Programmable Output 1 to 99 seconds Door Open Time Default 5 seconds Latching Off Default Manual Toggle On O...

Page 14: ...ay see page 11 that will activate either a Fail Safe or a Fail Secure Non Fail Safe electronic locking device or other equipment It may also be configured with an external relay as a dry contact relay...

Page 15: ...of the following 1 CCTV or Light Controller First key press triggers a Timed Output 1 to 99 seconds 2 Auxiliary Output Manual Control or Timed Output 1 to 99 seconds 3 Third Door Users can be assigne...

Page 16: ...and causes 3 Proceed to one of the following eight programming options Changing the Master Code Default 1 2 3 a Enter 1 b Enter the New Master Code followed by c Return to Step 3 or enter to exit prog...

Page 17: ...n LED a Double Slow Flash Slow Flash b Triple Slow Flash Solid Setting Latching Option Default Off a Enter 3 b Select the desired latching option Off 0 Manual 9 9 Timed Enter the desired time interval...

Page 18: ...mple 4 2 0 Sets Auxiliary Device with Manual Operation Second Door 1 Enter 3 2 Enter the desired Door Open Time 1 99 seconds followed by 3 Select the desired latching method Off 0 Manual 9 9 Timed Ent...

Page 19: ...1 Enter 2 2 Enter the momentary output time 1 99 seconds followed by or Enter 0 to set the auxiliary device for Manual Operation ON OFF followed by Example 5 2 0 Sets Auxiliary Device with Manual Ope...

Page 20: ...master code to unlock the door d Return to Step 3 or enter to exit programming Time Clock Input Default Prevent a Enter 7 b Enter 0 to prevent lockout c Enter 1 to lockout all users that do not have 2...

Page 21: ...2 3 This opens programming and causes 3 Proceed to one of the following seven programming options Adding a New User a Enter 1 b Enter the User ID 1 to 500 followed by c Enter the User Code PIN 3 8 dig...

Page 22: ...Step Completion Step Beep Red LED Green LED a Double Slow Flash Slow Flash b Double Slow Flash Fast Flash c Double Slow Flash Fast Flash d Double Slow Flash Fast Flash e Double Slow Flash Fast Flash...

Page 23: ...horization 2 Program or Delete Users Authorization 3 Output AAuthorization see notes 4 2nd Door see notes 5 Output B Authorization see notes 6 3rd Door see notes 7 24 hour Access see notes e Enter to...

Page 24: ...modify an additional User return to Step b g If no more Users are to be modified enter and return to Step 3 or if you have completed all User Programming enter a second time to complete programming s...

Page 25: ...programming sequence and reset system to normal operation Adding a Temporary User a Enter 6 b Enter the User Code PIN 3 8 digits followed by c Enter the desired Temporary access Time 1 99 hours follo...

Page 26: ...mands depends on authorizations assigned to each User see Program ming Individual Users page 17 As the Main Output activates the green LED will flash for 5 seconds While the green LED is flashing ente...

Page 27: ...23 Essex Electronics Inc 805 684 7601 800 KEY LESS fax 805 684 0232 keyless com Notes...

Page 28: ...that has been discontinued proves defective and if Essex Electronics Inc is unable to repair or replace the product within the terms expressed in this Limited Lifetime Warranty a substitute product m...

Page 29: ...our factory with transportation charges paid by the Buyer Limited Lifetime Warranty The Essex Electronics Inc products with a manufactured date of 5 1 06 to the present date that are covered by this...

Page 30: ...bove under any tort negligence strict liability contract or other legal or equitable theory or for incidental or consequential damages or buyer s cost of effecting insurance coverage The foregoing lim...

Page 31: ...800 KEYLESS 800 539 5377 to obtain an RA All returns must be sent to the factory freight prepaid Collect shipments will not be accepted at any time Standard turnaround time is ten 10 working days fro...

Page 32: ...Essex Electronics Inc 805 684 7601 800 KEY LESS fax 805 684 0232 keyless com...