manualshive.com logo in svg
background image

VANDAL RESISTANT

    DIGITAL

 

KEYPAD WITH

DELAYED EGRESS FEATURE

            AND 1000 USER CODES

 

            

Post Mount Keypad 

             

Programming & Installation Manual

Содержание ASE-KP1000EGRESS

Страница 1: ...VANDAL RESISTANT DIGITAL KEYPAD WITH DELAYED EGRESS FEATURE AND 1000 USER CODES Post Mount Keypad Programming Installation Manual...

Страница 2: ...digits and To program Relay 1 users 6 To set USER CODE 1 Press 102 then 001 and 4 digits and 7 To set USER CODE 2 Press 102 then 002 and 4 digits and 8 To set USER CODE 3 Press 102 then 003 and 4 digi...

Страница 3: ...ck mounts or on posts and walls TERMINAL CONNECTIONS FOR THE POST MOUNT KEYPAD 12 24V AC DC POWER INPUT Connect to 12 24V AC or DC power supply The supply and GND are the common grounding points of th...

Страница 4: ...o turn on lights CCTV camera or buzzers to notify a guard This output is rated at I c max 100mA sink V c max 24VDC DU OUT Duress Output is an NPN open collector output transistor that switches to grou...

Страница 5: ...tion time While one of the doors in the system is opened the other doors keeps closed until the first door is closed to prevent unauthorized people dashing into a protected area N C TAMPER Normally Cl...

Страница 6: ...on Comments 5 1 5 1 0 5 2 1 to 999 From 1 to 999 seconds default is 5 seconds Output 1 in Start Stop Mode toggle Output 1 in Start Stop Mode toggle with accelerated code 5 2 5 2 0 1 to 999 Output 2 in...

Страница 7: ...e same length as the Master Code Tones are active on key press Tones are off Use for silent environment requirements NOTE In single user mode if selection is auto or manual mode the Master Code and th...

Страница 8: ...ation Visitor ID Valid Period 4 digit code Visitor Code Codes not valid after one use or time expires Validation MASTER CODE Programming and use of t he keypad Operation Examples A Programming Procedu...

Страница 9: ...2 1 1 0 2 0 0 2 6 8 5 4 5 1 1 0 5 2 6 0 1 0 System has been placed in program mode with factory set Master Code System has been set for Single User Mode see note a below 3289 has been stored as the n...

Страница 10: ...Enter false codes into the keypad to test the security The keypad considers 4 digits as 1 code and it generates 5 beeps for each unsuccessful entry The keypad will lock for 15 minutes after 10 unsucc...

Страница 11: ...mming mode All changes are stored system is ready to use 8 3 2 1 Output 1 activates for 1 second 1 1 2 1 Output 1 activates for 1 second 3 3 2 2 Output 1 activates for 1 second 2 Programming Note a In...

Страница 12: ...Output 1 as if User Code 1 has been used The Duress Code can always activate or deactivate in Start Stop mode Output 1 but cannot deactivate the Duress Output Only the User Code in Group 1 can reset...

Страница 13: ...nt All weather IP 66 Operation Modes a Single User Mode Auto or Manual Code Entry b Multi User 100 user codes for output 1 user number 00 99 Auto or Manual Code Entry 10 user codes for output 2 user n...

Страница 14: ...ith the lock terminals to absorb the back EMF to prevent damage to the keypad The 1N4004 is not required if the electric lock is AC operated To avoid Electro Static Discharge from interfering with the...

Страница 15: ...operation of the electric lock at night or after office hours to prevent unauthorized access Set output 2 to Start Stop toggle Mode Program Option 51 for ON Off control Simply connect the output 1 in...

Страница 16: ...s necessary to link up the GND terminals of the two keypads as common ground to achieve the inter lock logic function Use keypad to open door from outside Press egress button to open door from inside...

Страница 17: ...Alarm The keypad will generate an alarm if the door is left open longer than the pre set time Enable the function with Program Option 9 with duration of 1 to 999 seconds With the help of a normally cl...

Страница 18: ...17...

Страница 19: ...en when activated N O Normally Open the contact is open circuit in a normal status It is closed when activated Transistor Open Collector Output An open collector output is equivalent to Normally Open...