Installation and operating instructions 

 

Swing Gate Opener 

KOMET 200 - 600 

 
 

 

 
 

 

Translation of original installation and operating instructions

 

D-ID: V2_3 – 01.14 

 

ELKA-Torantriebe GmbH u. Co. Betriebs KG

Phone: 

+49-(0) 48 61 - 96 90-0 

Dithmarscher Str. 9 

Fax: 

+49-(0) 48 61 - 96 90-90 

25832 Tönning 

E-mail: 

[email protected] 

Germany Internet: 

www.ELKA-Torantriebe.de 

  

 

Summary of Contents for KOMET 200

Page 1: ...ranslation of original installation and operating instructions D ID V2_3 01 14 ELKA Torantriebe GmbH u Co Betriebs KG Phone 49 0 48 61 96 90 0 Dithmarscher Str 9 Fax 49 0 48 61 96 90 90 25832 T nning...

Page 2: ...llation information for partly completed machinery 9 4 2 Declaration of conformity 9 4 3 Name plate 9 5 Usage 10 6 Technical Data 11 7 Installation example 13 8 Installation 14 8 1 Installation dimens...

Page 3: ...KOMET 200 600 2 10 7 Fault diagnosis 42 10 8 Emergency mode 43 10 9 Parameter and Original settings 44...

Page 4: ...himself or others will result from this use He should also ascertain that the planned use will have no detrimental effect on the appliance itself The appliance should only be used when all safety equi...

Page 5: ...ies if it is not avoided ATTENTION points to a potentially dangerous situation which can cause property damage if it is not avoided REMARK Important notice for installation or functioning 1 2 Copyrigh...

Page 6: ...ning according to the standards and regulations at least once a year 2 3 Safety notes for the operation with radio remote control The radio remote control should only be used if the area of movement o...

Page 7: ...able components can cause serious injuries Do not reach into moving parts or handle any moving components during operation Turn the appliance off before any maintenance work repair work or other work...

Page 8: ...xtent on the delivery receipt or refuse acceptance Inform ELKA Torantriebe immediately in the event of damage In case the above points are not observed claims will be denied due to insurance regulatio...

Page 9: ...KOMET 200 600 4 Declaration of incorporation Drawing 1 8...

Page 10: ...nly certified electricians VDE 0100 should connect the controller to the mains supply According to DIN EN 12453 for an application with passenger traffic depending on the type of use and type of activ...

Page 11: ...of series KOMET 200 600 are designed for gates moving horizontally and having low wind resistance For max width and weight of gate wing see table and diagram below When usage is different from the ab...

Page 12: ...rox 16s stroke 300mm approx 13s stroke 350mm approx 16s stroke 320mm approx 14s stroke 350mm approx 16s stroke 440mm approx 21s stroke 500mm approx 24s Opening angle max 120 External limit stoppers at...

Page 13: ...requency of use We recommend maintenance at least once every 12 months Table1 gates with low wind resistance depending on the installation dimensions stroke and the speed level depending on the instal...

Page 14: ...KOMET 200 600 7 Installation example Drawing 2 13...

Page 15: ...KOMET 200 600 8 Installation 8 1 Installation dimensions pivot point All measurements are quoted in millimetre The opener KOMET is for usage left and right Drawing 3 14...

Page 16: ...KOMET 200 600 KOMET 200 280 400 C approx 100mm D approx 80mm E 1010mm Drawing4 KOMET 600 C approx 100mm D approx 120mm E 1245mm Drawing 5 15...

Page 17: ...Table of opening angels KOMET 280depending on measurements A and B Opening angle A B A B A B A B 90 150 150 160 160 170 170 180 180 95 150 140 160 150 170 160 180 170 100 160 140 170 150 180 160 105...

Page 18: ...ements reduces the opening angle Please strictly observe the approved measurements This is necessary for an optimal operation In case these measurements cannot be observed please send us your dimensio...

Page 19: ...ction point of the mounting support T at the gate Make sure that the distance to the gate is sufficient so that the gate opener does not touch the gate later during movement Using a water level determ...

Page 20: ...w the periphery equipment like key switches photo cells etc and lay the electrical cabling according to the installation example on page 13 Make sure that the cable cannot be tensed or damaged by the...

Page 21: ...parately into the end positions in slow mode dead man s function The main wing moves into direction OPEN only as long as button BT is pressed When button BT is pushed again the wing moves into directi...

Page 22: ...ion CLOSED Should the gate now be in position OPEN the wires 4 and 5 of the motor connection cable at the 5 pin connection have to be switched Then repeat by pressing button BTG once 1x display p1 and...

Page 23: ...from the controller MO 36 that at least one opener is disengaged 9 2 Engaging of emergency release Insert the wrench into the emergency release Turn the wrench approx turn clockwise The overcoming of...

Page 24: ...tance Power supply for the controller 230Vac 50Hz single Phase Connection By fixed wiring and main switch on site or flexible wiring with cable stress relief device according to the European standards...

Page 25: ...10 2 1 Connection plan of the controller MO36 Each safety contact strip terminal which is not used has to be linked to an 8 2k resistor Each photo cell and stop terminal which is not used has to be li...

Page 26: ...to EN954 1 category 2 Ground 1 pin Mutual ground LSA and LSI SLA SLZ Safety contact profile resistor detection n c contact with 8 2k resistor serial or parallel with n o contact with 8 2 k 2 pin Inte...

Page 27: ...ghts when safety contact profile SLZ active OFF BT Green Lights when the contact is closed OFF when pushing button ON BTG Green Lights when the contact is closed OFF when pushing button ON BA Green Li...

Page 28: ...E 1 pin Earth AMPEL 2 pin Socket for traffic light module AMO34A red green Table 10 10 3 Programming MO36 For programming and to set operating parameters use the two digit 7 segment display and the bu...

Page 29: ...vating deactivating photo cell testing pb Activating deactivating lockage function for photo cells pc Selecting pressure relief of electromagnetic bolt pd Selecting wind blast suppression pe Selecting...

Page 30: ...ed during each wing movement After the learning of the running distance returning to the main sequence follows automatically Remark After adjustment of the end stoppers the wings should not be in eith...

Page 31: ...Possible values are 00 for 0s up to 09 for 9s The value can be increased using button BT and decreased using button BTG Return to the learning sequence using button LERN Remark When a time lag is sel...

Page 32: ...rol code is already stored and can be overwritten or deleted Table 16 To erase the radio remote control code press and hold the button BT and additionally push the button LERN The radio remote control...

Page 33: ...lapsing when the last wing has reached the position OPEN When contact BS is opened the automatic closure function is blocked When the stay open time has elapsed and the safety contact profile for dire...

Page 34: ...arts elapsing when the wing has reached the position OPEN When contact BS is opened the automatic closure function is blocked When the stay open time has elapsed and the safety contact profile for dir...

Page 35: ...o4 No warning time 4 seconds warning time 4o 4 seconds warning time No warning time 44 4 seconds warning time 4 seconds warning time Table 19 10 3 1 9 Sequence P9 Photo cell function When sequence P9...

Page 36: ...rupted closes when free again LSA Remains not moving Stops when interrupted opens when free again Stops when interrupted closes when free again l3 LSI Only closing allowed Stops when interrupted opens...

Page 37: ...photocells with the controller MO 36 Therefore add all n c relay contacts of the receivers in serial Parallel to each relay contact you must add a 1kOhm resistor resistors are needed only when photoce...

Page 38: ...m the inside a signal from LSI blocks the automatic closure function Only the signal from LSA removes the blocking and starts the stay open time When sequence PB is activated by button LERN the presen...

Page 39: ...ed see table Return to the learning sequence using button LERN Display Corresponds to u No wind blast suppression The controller immediately reacts on obstacle wind blast u1 bis u9 The wind blast supp...

Page 40: ...ivated by button LERN re is displayed To return to original settings press and hold button BT and push button LERN When only button LERN ispushed you return to learning sequence without changing any v...

Page 41: ...n emergency mode Opening Stop and movement for a short distance into direction closed Closing Stop and re opening Table 26 Automatic closure When the gate hits an obstacle during closing and reversing...

Page 42: ...After the open time has elapsed the timer sends a CLOSE command to the controller Note When the timer sends the CLOSE command the gate is closed immediately even when automatic closure is activated 10...

Page 43: ...e5 Running distance exceeded gate was stopped Check end stoppers and re learn the running distance e6 The power supply limit for the external equipment 12V has been reached The power source load is t...

Page 44: ...ice is faulty the gate can be moved by BA and BZ The buttons BA and BZ therefore have to be installed in such a way that the gate can be seen during movement WARNING Are external devices giving a cons...

Page 45: ...ttings Running distance Max 32 000 Impulse 3 000 Impulse Force 1 99 30 Speed 1 8 8 Time lag during opening 0s 9s 2s Time lag during closing 0s 9s 5s Stay open time for both wings 1s 299s OFF OFF Stay...

Page 46: ...KOMET 200 600 45 Radio remote control code BT X Code All other radio remote control codes X Code deleted Table 30...

Page 47: ...22 F Fault diagnosis 42 G General notes on safety 5 I Installation example 13 Intended use 5 L learning sequence 27 N Name plate 9 O Original settings 44 P Parameter 44 Power failure 42 R radio remote...