background image

Supplemental Manual

For Generating Hypochlorous Acid (HOCl)

How to Generate HOCl

The purpose of this supplemental manual is to explain 

how to generate higher concentrations of HOCl using 

less salt and 

to present several options for optimizing 

the pH to between pH 5 and pH 7.

1.

Ad

1 Liter of

 reverse osmosis water (RO water should have pH <6)

 

If RO water is unavailable, use purified water or tap water and

 

lower

 

the pH by choosing one of the following methods:

a)

Add 1 

teaspoon of 5% distilled vinegar

  - or -

b)

Add 1 drop of muriatic acid (32% HCl) *

2.

Add 1 gram of salt . May also use as little as 1/2 gram.**

3.

Place 

on 

lid and plug-in the power supply ***

4.

Run 

S

etting 3 once (8 minutes) to generate ~100 ppm

Run 

S

etting 3 twice (16 minutes) to generate ~200 ppm

Each additional run on setting 3 will increase the

concentration by 

6

0-

8

0 ppm

 for a maximum of 5 total runs.

1.

Lid

2.

Power On/Off

3.

Settings 3

4.

Settings 2

5.

Settings 1

6.

Power Slot

7.

One gram

measuring spoon

8.

Power supply

7

8

1

2

3

4

5

6

Press to Power On

Press once for Setting 1
Press twice for Setting 2
Press three times for Setting 3

Setting 3 – System runs for 8 minutes

 

Setting 2 – System runs for 5 minutes

 

Setting 1 – System runs for 3 minutes

 

*

Personal protective gear is required when using muriatic acid. '

This is the same muriatic acid that is used to lower the pH of pools.

**

 

Salt must be food grade salt (NaCl) without iodine (ie. kosher salt). When using

less than 1 gram of salt, it may be required to run 1 extra cycle of 8 minutes.

***

 

Power supply must be dry

Reviews: