background image

Dromex: Unit 1, 1 Blase Road, New Germany, 3620, South Africa

T. +27(31) 713 1960   E. [email protected]

www.dromex.co.za 

FULL FACE MASK RESPIRATOR
DH FFM

Description

The Dromex® DHFFM full face mask provides the user with unparalleled 
vision, comfort and reliability protecting against hazardous vapours, gases 
and particulates, provided there is sufficient oxygen present in the 
contaminated atmosphere.
The Dromex® full face mask utilizes the Dromex® twin uni-fit cartridges and 
pre-filters only.

Special Instructions

All respiratory selections should be read in conjunction with BS EN 529:2005 
“Respiratory Protective devices – Recommendations for selection, use, care and 
maintenance”.
Do not use these respirators or enter in area where:
     • The oxygen concentration is not known or is less than 19.5%.
     • Contaminants or their concentrations are unknown or are known to be 
       immediately dangerous to life or health.
    • Particulate concentrations exceed levels fixed by the applicable health 
       and  safety regulations or protection factor 40 NPF whichever is lower.
    • Gases and/or vapours are present except for respirators designated as 
       protecting against vapours, in which case vapour concentrations should 
       not exceed 20 NPF.
     •  The requirement for leak tightness is unlikely to be achieved if worn 
       against a beard or facial stubble.
     • Do not wear standard eye glasses with a full-face respirator
     • Not to be used for firefighting.
     • These respirators do not supply oxygen. Do NOT use in oxygen deficient 
       atmospheres (e.g. tanks or other poorly ventilated areas).
     • Do not use in explosive atmospheres.
     • Do not modify or alter this device.

Compliance & Conformity

NRCS Homologated to SANS 50136:1998 CL1 as required by the Occupational 
Health and Safety Act, 1993 (Act No. 85 of 1993) 
EN136:2008 approved: Respiratory protective devices full face masks — 
Requirements, testing, marking quality system as per ISO9001:2008.

Specifications

Type:         

Class1 full face masks for light duty use

Material:    

Thermo Plastic Elastomer/Rubber

Colour:       

Black

Harness:    

5-point comfort harness with 2 grip holes for easier fitting 

  on and removing with gloves and accommodation of 
  women’s hair (ability to wear a pony tail). 
  Withstands a pull of up to 15KG or 150N
Visor:         

Polycarbonate anti-fog and impact resistant with 

 

 

peripheral optical vision of 220 degree’s (110 on the left 

  and right). The natural field of vision is greater than 
  the 70% specified of EN136:2008 standards. 
One size mask body:  Accommodates small to large facial size's 
Temperature:  

Designed to withstand temperatures of up to 70 ± 3˚ 

  Light weight dual filter cartridge system evenly 
 

 

distributes weight of mask and cartridges on the face.

DHFFM

10

-20˚C

+40˚C

<75%

RH

DHFFM

Packaging, Storage & Obsolescence

DHFFM - Packed individually sealed in cardboard box,10 masks per 
carton for shipping. 
When not in use, store the full-face mask with filters in the Dromex® 
full face mask storage bag that can be worn on the operator’s waist.
Store in a cool dry place, away from direct sunlight at temperature 
between-20˚C and + 40˚C and where relative humidity  is less than 
75% and away from sources of possible contamination and physical 
damage.

Cleaning & Maintenance

- Remove cartridge filters from connectors and all inhalation and 
   exhalations valves.
- Clean / disinfect the face piece and components with a damp cloth, 
   using lukewarm with all-purpose detergent 
   (neutral, pH 6-8, e.g.: washing-up liquid), warm soapy water or cleaning 
   solution not exceeding 30 degrees.
- Do not immerse the product in water or use abrasive cleaners.
- Do not use solvents (e.g alcohol, acetone, turpentine), hot water, strong 
   detergents, bleaches or petroleum based products to clean any part of 
   masks.
- Dry in air at room temperature.
- Replace all components after cleaning and inspect for visible damage.

Shelf life

5 years, with correct maintenance and storage procedures. Discard 
immediately if mask is damaged and tears are visible.

Materials

None of the materials used in the manufacture are known to adversely 
affect the hygiene or health.

Disposal

All industrial waste should be disposed of correctly according to local 
regulations and good disposal practice. Respiratory protective 
devices should be disposed of considering the hazardous substance 
they were used for. Please consider recycling.

Reviews: