END USER GUIDE

RCI  DE8310 V1.6

DELAYED EGRESS V1.6 ELECTROMAGNETIC LOCKS

  © 2020 dormakaba Canada Inc

www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: [email protected]

ZLDE8310EUG-V16

PCN18041 

R01-20GR

PLEASE GIVE TO END USER

Nuisance Period:

 Some installations have a short nuisance period set to accommodate accidental triggering. 

If the pressure on the door is withdrawn during the nuisance delay period, the system returns to normal conditions on its own.  

System Status

Light Panel *

Local Buzzer

(if connected)

Local Alarm Relay Output 

(if connected)

Remote Alarm Relay Output 

(if connected)

Nuisance Delay 

Period

Blinking Red

fast

Pulsing Sound

ON

ON

System Status

Light Panel *

Local Buzzer

(if connected)

Local Alarm Relay Output 

(if connected)

Remote Alarm Relay Output 

(if connected)

Release Delay 

Period

Blinking Red -  

slowly

Steady Sound

ON

OFF

Lock Release

Blinking Red & Green - 

alternately

Steady Sound 

until reset

ON

OFF

Normal Conditions:

 In normal conditions with the door closed and locked.

System Status

Light Panel *

Local Buzzer

(if connected)

Local Alarm Relay Output 

(if connected)

Remote Alarm Relay Output 

(if connected)

Door Locked

Green

OFF

OFF

ON

System Status

Light Panel *

Local Buzzer

(if connected)

Local Alarm Relay Output 

(if connected)

Remote Alarm Relay Output 

(if connected)

Exit Switch to Open  

(Authorized Exit)

Red 

OFF

OFF

OFF

To Exit: 

If a Nuisance Delay is enabled, maintained pressure past its time will start the irreversible release delay.

If a Nuisance Delay is not enabled, slight pressure will start the irreversible release delay.

 

The release delay time is posted on the door.  

Pressure is no longer required on the door.

The lock will release when the delay period ends. 

The system now needs to be manually RESET using the keyswitch in order for the buzzer to stop.

To By-Pass the Delay Period and Exit:

 Manually OVERRIDE using the keyswitch to release the door. 

When the door closes, the system returns to normal conditions.

Door Forced Open: 

 If this happens before the release delay period has lapsed, the buzzer indicators can only be turned off by switch-

ing the system power off.

System Status

Light Panel *

Local Buzzer

(if connected)

Local Alarm Relay Output 

(if connected)

Remote Alarm Relay Output 

(if connected)

Forced Open

Blinking Red - Fast

Pulsing Sound

ON

OFF