background image

 

 

 

 

 

 

 

 

 

 

 

 

 

flexx 

Wiring & Installation 

Instructions 

#896087 

Summary of Contents for proxSafe flexx

Page 1: ...flexx Wiring Installation Instructions 896087...

Page 2: ...opying recording or otherwise without prior written permission of deister electronic GmbH deister electronic GmbH reserves the right to make changes to any and all parts of this documentation without...

Page 3: ...onnection with proxSafe terminal 23 3 8 3 Network connection without proxSafe terminal 24 3 9 Operating the flexx without Ethernet Network 25 3 9 1 Connect PC with proxSafe terminal via USB adapter 25...

Page 4: ...t approx 12 kg Housing Small approx 20 kg Housing Medium approx 60 kg Housing Large keyPanel options 3U with 16 proxCylinders 480 mm x 132 5 mm 6U with 16 proxCylinders 480 mm x 265 5 mm Door options...

Page 5: ...front door 2 keys for the service door In addition to that there are packages each containing 1 proxSafe flexx keyPanel with 16 proxCylinders 16 proxSafe keyTags 16 proxSafe keyRings 25 pairs of proxS...

Page 6: ...ely intended for installing a reader into a proxSafe C3 terminal 1 Remove the two front screws of the terminal housing and carefully open the housing 2 Remove the two screws of the reader compartment...

Page 7: ...ng screws 6 Put the two screw covers in place In case you want to install the terminal on the left hand side of the housing continue with the next chapter If your prefer right hand side mounting skip...

Page 8: ...left side you need to prepare the terminal bracket as follows 1 Remove the two front screws of the terminal housing and carefully open the housing 3 Remove the four screws between the two parts of th...

Page 9: ...ull the handle to open the door 2 Now insert the service key into the inner service door and turn it again anti clockwise Then carefully pull to open the service door Note The standard delivery will p...

Page 10: ...om and top of the left side in which the door pins had been inserted before and put them into the according wholes on the right side of the housing top and bottom Then push the plastic cover the one y...

Page 11: ...the inside back through the hole on the right side of the housing 7 Loosen the two screws from the door lock of the front door with a socket wrench as shown above and take it off from the housing 8 N...

Page 12: ...or pull the door lock slightly into a position where the front door can be closed with a clear clicking sound but will not be jammed or have too much tolerance in the last case the door lock may not...

Page 13: ...de of the housing 1 Guide the two terminal cables through the hole in the back of the terminal bracket 3 Fix the terminal to the flexx frame with the two enclosed screws use a short or an angled screw...

Page 14: ...y has been guided into the inside a possible network cable has been guided into the inside Now you can start mounting the flexx to the wall by using the provided wall mounting rail see drawing below a...

Page 15: ...proxSafe flexx 3 4 1 Wall mounting flexx 6U V08 09 09 ps_flexx_wi_en 15 Picture 1 front view of proxSafe flexx 6U housing...

Page 16: ...proxSafe flexx 16 ps_flexx_wi_en V08 09 09 3 4 2 Wall mounting flexx 12U Picture 2 front view of proxSafe flexx 12U housing...

Page 17: ...proxSafe flexx V08 09 09 ps_flexx_wi_en 17 3 4 3 Wall mounting flexx 24U Picture 3 front view of proxSafe flexx 24U housing...

Page 18: ...Connect external wall power supply Attention At this point of installation there is a non connected high voltage cable leading into the inside of your flexx housing For safety reasons we recommend to...

Page 19: ...as well with blind plates if these are part of your delivery 2a The service door should now look like this from the inside After having mounted all the keyPanels into the service door plug the connect...

Page 20: ...set the jumper J1 on the flexx backplane jumper closed as shown in the picture below Otherwise there will be no power supply for the backplane picture 3 7 1 jumper setting for J1 if operated without p...

Page 21: ...and how to set the jumpers 3 8 1 Install Digi Connect ME Adapter onto backplane PCB 1 The DigiCon adapter is supplied on a small piggyback board and can be mounted directly onto the flexx backplane PC...

Page 22: ...kplane PCB to its position and carefully click it back on the plastic studs 6 Connect the DigiCon to your network with the network cable which has been guided through the cable outlet before mounting...

Page 23: ...B see 3 11 Connect terminal to backplane PCB the network cable is correctly connected to the DigiCon see 3 8 1 picture 6 the jumpers J4 and J5 on the backplane PCB are set according to the drawing bel...

Page 24: ...he proxSafe terminal you may connect the PC directly to the backplane PCB In this case you should take care that the network cable is correctly connected to the DigiCon see 3 8 1 picture 6 the jumpers...

Page 25: ...1 If you want to connect an earlier version of SNG3 adapter with two green LEDs and have problems with powering use an additional power supply for the SNG3 itself For further information ask your loc...

Page 26: ...n for operating the flexx system using the proxSafe terminal without network connection is to directly connect the PC to the backplane PCB For this connect the SNG 3 as follows 1 Set both dip switches...

Page 27: ...SNG 3 are as follows 1 Set both dip switches on the adapter as follows a 1 flexx backplane both On b 2 or more flexx backplane PCBs with SNG 3 at end of bus line both On c 2 or more flexx backplane P...

Page 28: ...12 Connect LEDs In order to connect the LEDs on top of the flexx housing proceed as shown in the picture below Plug the LED cable coming down within the housing from the LEDs on top of the flexx into...

Page 29: ...stem to control the front door the door contact has to be connected to the flexx backplane PCB Therefore two different jacks on the flexx backplane need to be connected to the 4 core cable coming from...

Page 30: ...power supply of the backplane PCB this tamper alert will naturally fail to report any sabotage actions in case of a forced disconnection from the power supply The left external tamper switch b in pict...

Page 31: ...ee disposal for customer Please remove tape from metal straps to activate both switches 2 Diagram of independent tamper switch left side status open alarm case 3 Inputs on the flexx backplane PCB for...

Page 32: ...ly see 3 5 Connect external wall power supply For connection of the internal power supply unit and the back up battery use the cables which have been supplied with your flexx system 1 Connect the powe...

Page 33: ...nector on backplane A see in picture above RJ45 connector on backplane B as shown exemplary with the two isolated backplanes in picture 2 b 2 b Important If you plan to connect more than two flexx hou...

Page 34: ...nd one pair of one time seals And the keys you want to attach 3 Place the keyRing into the keyTag 5 Put the other seal plug into the opposite side of the keyTag hole 2 Put one or more keys on the keyR...

Page 35: ...proxSafe flexx V08 09 09 ps_flexx_wi_en 35 7 Ready 8 If you need to open the seal put it into the de sealing tool and push to destroy the seal plug...

Page 36: ...ed proxCylinders per row For example for the proxSafe flexx keyPanel 3U with 16 slots this should always be 8 8 0 0 The commissioning procedure will then run through every connected flexx keyPanel cou...

Page 37: ...he first card presented to the terminal will be registered by the terminal as Administrator card The administrator status can be changed later on within the according PC Software We strictly recommend...

Page 38: ...Tag into one of the free proxCylinders Insert a keyTag now into one free proxCylinder of the first flexx housing You will hear a beep and the display shows the following screen Now you can remove the...

Page 39: ...ll keys have been inserted into the flexx housings your proxSafe flexx system is ready for test operation 5 5 Test Operation With the above procedure you have created a minimum key management system w...

Page 40: ...Cylinder by hand for manual keyTag release In this case the service door of the flexx has to be opened first see 3 2 Open flexx Each single proxCylinder is equipped with a little metal lever on its ow...

Page 41: ...deister electronic declares that the radio equipment type flexx is in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is available at the following internet add...

Page 42: ...proxSafe flexx 42 ps_flexx_wi_en V08 09 09 Notes...

Page 43: ...proxSafe flexx V08 09 09 ps_flexx_wi_en 43 Notes...

Page 44: ...5 92 59 info fr deister com Great Britain deister electronic UK Ltd Stapleton Way Enterprise Park Spalding Lincolnshire PE11 3YQ Tel 44 0 1775 717100 Fax 44 0 1775 717101 info uk deister com Japan dei...

Reviews: