background image

 

 

USER’S MANUAL 

 

MA08-02/B 

15/09/2011 

 
 
 

 

 

www.davicia.com 

Summary of Contents for MA08-02/B

Page 1: ...USER S MANUAL MA08 02 B 15 09 2011 www davicia com ...

Page 2: ... Programming the ticket 4 1 7 Coin operated 4 1 8 Language 4 2 Adjust 4 2 1 Adjust weight 4 2 2 Adjust height 4 3 Test 4 3 1 Test of weight 4 3 2 Test of height 4 3 3 Test of ADC 12 12 13 13 13 13 14 14 15 15 15 15 16 16 16 16 17 5 5 5 5 MAINTENANCE AND CLEANING MAINTENANCE AND CLEANING MAINTENANCE AND CLEANING MAINTENANCE AND CLEANING 5 1 Paper roll change 5 2 Equipment disposal 18 18 19 6 6 6 6 ...

Page 3: ... sensor 2 Height meter arm 3 LCD display 4 Weighing platform 5 Adjustable feet 6 Height meter arm fixing 7 Connector panel 8 Power supply connection 9 ON OFF switch 10 Auxiliar connection 11 RS232C serial interface for PC connection 1 2 3 4 5 6 7 8 9 10 11 ...

Page 4: ...d is ready for operation immediately after unpacking Connect the device to the power supply via the power supply cable It is necessary that the outlet is provided with grounding Adapters should not be used without grounding 2 1 2 1 2 1 2 1 UNPACKING UNPACKING UNPACKING UNPACKING Remove the packaging as shown in the Figures below ...

Page 5: ... SCALE ASSEMBLY SCALE ASSEMBLY SCALE ASSEMBLY SCALE ASSEMBLY o Carefully place the equipment on its side 07 and attach the column from underneath the scales platform 08 using the screws o The weighing cell cable has to be passed through the pipe The end of the cable is taped to the cable grip strip supplied and it is threaded through the pipe until it appears out of the top 09 13 o Connect the wei...

Page 6: ...USER S MANUAL MA08 02 B 5 ...

Page 7: ...with the height measurement arm move the display to cover the hole Remove the retaining screws on the lower section move the console and attach it again in the new position The console has to be properly held in the rear position Attach the cover supplied using the 4 screws Insert 2 plugs to cover the height measurement arm s holes ...

Page 8: ... its mounting 2 2 2 2 3 3 3 3 LOCATION AND SETTING LOCATION AND SETTING LOCATION AND SETTING LOCATION AND SETTING Set the equipment in a place flat and level where it is perfectly supported This last point is of vital importance to proper operation Make sure that within a radius of 70 cm around the equipment there is no interference that might affect the measurement of height To make sure that the...

Page 9: ...ts are placed on the platform of the equipment o Actuate the switch on the bottom o At this point the equipment will perform the process of self test o Step away from the equipment to not interfere in the process of auto zero of the systems of weight and height o If the process of self test completes successfully the screen displays 0 0 kg ...

Page 10: ... pens finger nails etc Breakage or malfunction of the keypad as a result of such improper use is not covered by the guarantee Function Function Function Function Activates the scale when it is in energy saving mode Provides access to the programming menu Prints out the ticket with the results Down arrow key lowers the value or the menu option Male key indicates the male gender OK key confirms opti...

Page 11: ...ng that the weight is stable and indicating that Tare function is active o Step up now with the baby on the scale platform the display only shows the baby s weight value with a precision of 10g We can make as many weighings as we wish Stepping off the platform it shows on the screen o By a further long press of the TARE key the function Tare is disabled its indicator disappearing from the screen 3...

Page 12: ...he BMI according to the WHO 16 Severe thinness 16 to 17 Thinness 17 to 18 5 Underweight 18 5 to 25 Normal range 25 to 30 Overweight 30 to 35 Mild obesity 35 to 40 Medium obesity 40 Morbid obesity 3 3 3 3 7 7 7 7 P P P PRINTED RESULTS RINTED RESULTS RINTED RESULTS RINTED RESULTS Upon completion of the selected measurements the equipment automatically prints a receipt depending on setup with the obt...

Page 13: ...arrow key lowers the value or the menu option Up arrow key raises the value or the menu option Confirms options Setup menu ADJUST WEIGHT Weight settings HEIGHT Height settings EXIT Exit settings menu TEST WEIGHT Weight test HEIGHT Height test ADC ADC test EXIT Exit Test submenu PROGRAM BMI Activate BMI UNITS Select units CLOCK Program date and time DATE MODE Date format PRINTOUT Printout mode TICK...

Page 14: ...nt and confirm by pressing OK kg m Kilos meters lb ft in Pounds feet inches st ft in Stones feet inches 4 4 4 4 1 1 1 1 3 3 3 3 Clock setting Clock setting Clock setting Clock setting This option allows you to program the date and time Select the CLOCK CLOCK CLOCK CLOCK option and the following screen will appear DD MM YY 0 Enter the date digit by digit using the arrow keys and confirm by pressing...

Page 15: ...option and the following screen will appear Line 1 Use the arrow keys to select the line from 1 to 4 you want to programme and confirm by pressing OK The following screen will then appear L01 01 _ The first line tells you the line number and the position of the character You can now start to enter the data for that line using the keypad You can use up to 24 characters per line Use the arrow keys t...

Page 16: ...ANGUAGE LANGUAGE option The display will show the following message 1 CASTELLANO 2 ENGLISH Indicate the language using the arrow keys and confirm by pressing OK 4 2 A 4 2 A 4 2 A 4 2 ADJUST DJUST DJUST DJUST DAVI equipments have been perfectly calibrated and tested so there is no need to make any prior adjustments for them to function correctly To access the adjust menu select the ADJUST ADJUST AD...

Page 17: ...IGHT HEIGHT HEIGHT option and the following screen will appear PROGRAM HEIGHT 0 cm Using the arrow keys you can increase or decrease the reference value Confirm it by pressing OK 4 4 4 4 3 3 3 3 TEST TEST TEST TEST To access the test menu select the TEST TEST TEST TEST option and the following options screen will appear 1 WEIGHT 2 HEIGHT 4 3 1 4 3 1 4 3 1 4 3 1 Test Test Test Test of weight of wei...

Page 18: ...st Test of of of of ADC ADC ADC ADC To access the ADC test select the ADC ADC ADC ADC option and the following screen will appear weight 519478 This test tells you whether the analogue digital converter ADC is working properly With no weight on the platform the equipment will show a value between 500000 and 600000 approximately It is important to make sure that the value is constant and any variat...

Page 19: ... maintenance check that only requires an annual maintenance check that only authorized personnel authorized personnel authorized personnel authorized personnel from the Davi Cia Technical Support Service from the Davi Cia Technical Support Service from the Davi Cia Technical Support Service from the Davi Cia Technical Support Service can perform can perform can perform can perform Clean the unit u...

Page 20: ...ated collection facilities appointed by the government or the local authorities This crossed out wheeled bin symbol on the product means the product is covered by the European Directive 2002 96 EC The correct disposal and separate collection of the equipment will help prevent potential negative consequences for the environment and human health It is a precondition for reuse and recycling of used e...

Page 21: ...A D Failure in load cell wires Failure in load cell mounting ZERO WEIGHT ERROR CODE 04 Error in Zero reading at machine start Failure in load cell Failure in A D Failure in load cell wires Failure in load cell mounting Knocks in load cell HEIGHT ERROR CODE 05 Height reading error Failure in height cell Failure in height circuit Failure in height wires Failure in power supply 12V E2PROM BASE CODE 3...

Page 22: ...ed 40 mm s Paper end detection using a photoelectric cell Paper width 60 mm e d Min Max Class 100 g 0 2 lb 100 g 0 2 lb 2 5 kg 5 5 lb 225 kg 500 lb III Fuses primary circuit Power supply 230V Power supply 115V 2 x 0 315 A 5 x 20 mm type T 2 x 0 630 A 5 x 20 mm type T Classification according to EN 60601 1 Electronic scale with height meter Equipment with metallic envelope and Class I of protection...

Page 23: ...4 3 2006 Campo radiado EM de RF EM radiated field of RF EN 61000 4 4 2004 Ráfagas de transitorios rápidos EFT burst EN 61000 4 5 2006 Ondas de choque Surges EN 61000 4 6 2007 RF en modo común RF common mode EN 61000 4 8 1996 A1 2001 Campo magnético a 50 Hz 50 Hz H field EN 61000 4 11 2004 Interrupciones de alimentación Dips interruptions ...

Page 24: ...fied free of charge upon presentation of the purchase receipt for the equipment No other rights can be taken into consideration Return shipment is at the customer s expense if the equipment is anywhere other than at the customer s headquarters In the event of damage during shipment guarantee rights will be granted only if the equipment is shipped in the original packaging You are therefore recomme...

Page 25: ...nical equipment Finalidad Prevista Equipo pesapersonas incorporando tallímetro Intended Use Weighing scales incorporating height rod CUMPLE LOS REQUISITOS DE LAS DIRECTIVAS CONFORMS WITH THE REQUISITES OF THE DIRECTIVES Pesapersonas Tallímetro Weighing scales Height rod EC Directive 2004 108 CE Directiva de Compatibilidad Electromagnética Electromagnetic Compatibility Directive EC Directive 90 384...

Page 26: ...uments are available on the web www davicia com www davicia com www davicia com www davicia com C Murcia 35 Nave G Pol industrial Can Calderón E 08830 Sant Boi de Llobregat Barcelona Spain Tel 34 93 654 32 32 Fax 34 93 654 16 62 info davicia com www davicia com ...

Reviews: