background image

Thank you for purchasing the Datapath iolite 600 wall controller. The 
aim of this document is to quickly guide you through the process of 
initial setup. For detailed instructions consult the system User Guide 
which can be found on the  Recovery Media.

Quick Start Guide

www.datapath.co.uk  |  [email protected]  |  +44 (0) 1332 294441

600

Summary of Contents for iolite 600

Page 1: ...er The aim of this document is to quickly guide you through the process of initial setup For detailed instructions consult the system User Guide which can be found on the Recovery Media Quick Start Guide www datapath co uk sales datapath co uk 44 0 1332 294441 600 ...

Page 2: ... leaflets Build Log MAC Address labels Each Datapath iolite 600 is custom built and therefore the number and type of input and output cards will differ from system to system Contained with this Quick Start Guide are PCIe card product leaflets which give details on how the cards are installed and any accessories which may accompany them Page 2 ...

Page 3: ...Connect Keyboard and Mouse to USB Ports STEP 2 KEYBOARD AND MOUSE STEP 3 CONNECT TO A NETWORK OPTIONAL Page 3 ...

Page 4: ...ild Log detailing the PCIe cards installed and where they are located on the backplane The enclosed Product leaflets give details on how the cards are connected Input Connectors The I O panel on your system may differ from the above illustration depending on which motherboard option has been supplied Refer to the motherboard documentation for detailed information Page 4 ...

Page 5: ... shown above If a control screen is not required the BIOS settings will require changing See the motherboard User Manual in your accessories pack for instructions on how to disable the internal graphics device 1 4 Monitor 2 Monitor 3 Monitor 4 Monitor 5 Monitor 7 Monitor 6 Monitor 8 Monitor 1 Connect graphic outputs to monitors using DisplayPort cables Not supplied Control Screen Optional 4 x 2Vid...

Page 6: ...STEP 6 POWERING UP THE SYSTEM Connect power cables then plug into a mains supply Switch on the system 2 1 2 1 Page 6 ...

Page 7: ...STEP 7 WINDOWS 7 SETUP The Product key is located behind the front panel Gently pull away the panel for access Page 7 ...

Page 8: ...opriate method available To view the Product Key remove the front panel The Product Key label is displayed on the front of the system STEP 8 ACTIVATE WINDOWS 7 Computer Name It is recommended that only Internet standard characters are used in the computer name The standard characters are the numbers 0 through to 9 upper and lower case letters from A through to Z and the hyphen character Computer n...

Page 9: ...1 2 3 Page 9 ...

Page 10: ...ers 0 through to 9 upper and lower case letters from A through to Z and the hyphen character Computer names cannot consist entirely of numbers contain spaces or use special characters such as There is no requirement for users to activateWindows 10 activation is completed automatically Enter localisation details STEP 10 WINDOWS 10 SETUP Page 10 ...

Page 11: ...Start Control Panel Display Change Display Settings 1 STEP 11 DISPLAY SETTINGS WINDOWS 10 2 3 4 Page 11 ...

Page 12: ...o 2 A representation of the display wall associated with the server 3 SourcesTab Displaying all the sources connected to the server for use on your display wall 4 LayoutsTab Use to save recall and share display wall layout configurations 5 TemplatesTab Use templates to assist in the design of specific display wall layouts Start All Programs WallControl 10 Server Before opening the Client interface...

Page 13: ...ources DisplayWall Tab DisplayWall Representation The WallControl 10 Security Administration Client ProVersion Only TheWallControl 10 Security Administration Client allows Administrators to assign specific users to roles on a wall by wall basis For example a user can be assigned a role allowing unrestricted access on one wall but assigned a role on another wall which only allows the opening of pre...

Page 14: ...ration Client will not open and an error message is displayed therefore it is important the dongle is not removed TheWallControl 10 Security Application help file contains information on how to Import users from theWindows Active Directory into the database Create and edit roles Assign permissions to providers layouts and sources giving specific roles access to them Assign roles to walls Page 14 ...

Page 15: ... or omis sions Datapath reserves the right to change specification without prior notice and cannot assume responsibility for the use made of the information supplied All regis tered trademarks used within this documentation are acknowledged by Datapath Limited EU Class A Declaration of Conformity Datapath Ltd declares that this product complies with the essential requirements and other relevant pr...

Page 16: ...nd 44 0 1332 294441 sales datapath co uk Datapath North America 2550 Blvd of the Generals Suite 320 Norristown PA 19403 USA 1 484 679 1553 sales datapath co uk Datapath France 33 1 3013 8934 sales fr datapath co uk Datapath Germany 49 1529 009 0026 sales de datapath co uk Datapath China 86 187 2111 9063 sales cn datapath co uk Datapath Japan 81 0 80 3475 7420 sales jp datapath co uk ...

Reviews: