background image

 

 
 
 
 
 
 
 
 
 
 
 

MCN RYB-8 Relay Board 

with Power and Termination Options 

 
 
 

Hardware Manual 

 

S2-60657-115 

 
 
 

 
 
 
 
 
 

 
 
 

 

 

68-11206-115

 

 
 

Summary of Contents for MCN RYB-8

Page 1: ...MCN RYB 8 Relay Board with Power and Termination Options Hardware Manual S2 60657 115 68 11206 115...

Page 2: ...constitutes the sole and exclusive remedy of the buyer and exclusive liability of CTI Products Inc AND IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED OR IMPLIED OR STATUTORY AS TO MERCHANTABILIT...

Page 3: ...nections J1 9 1 2 8 Relay Input Connections J2 10 1 3 MOUNTING AND CABLING 12 1 4 SPECIFICATIONS RYB 8 RELAY BOARD 14 1 5 SCHEMATIC RYB 8 RELAY BOARD 15 1 6 BOARD LAYOUT RYB 8 RELAY BOARD 16 2 HOT STA...

Page 4: ...CTI Products Inc MCN RYB 8 Relay Board Manual This page intentionally left blank ii 68 11206 115...

Page 5: ...onal EIA 19 rack mount panel available for mounting 4 MCN RYB 8 boards Part Number Description S3 60644 Basic board with no jumpers installed S2 60694 Board with standard jumpers installed E1 E8 B1 in...

Page 6: ...Relay Board Manual 1 1 1 Related Documents 1 MCN IOB Input Output Control Module Part Number S2 60630 2 MCN System Manual Part Number S2 60425 3 MCN Remote Comparator Display MCNRCD Manual Part Numbe...

Page 7: ...Side Each relay has its own jumper block E1 E8 to select the input that will drive the relay coil Each relay can be controlled from either I O bit 1 or 3 associated with it depending upon the position...

Page 8: ...input 9 40 Table 1 Sub Category Jumpers Since I O bit 1 is normally used to control the relay I O bits 2 4 are available for sub category selection Up to 8 sub categories can be configured with these...

Page 9: ...Normally Open Normally Closed or Common pair as shown in Table 2 and Figure 2 600 Ohm Termination E9 E16 Jumpers Installed None None or insert in Park positions Common Pair A1 B1 Normally Open Pair A...

Page 10: ...600 Ohm Termination Selection E14 6 600 Ohm Termination Selection E15 7 600 Ohm Termination Selection E16 8 600 Ohm Termination Selection E17 1 2 Adjacent relay coil selection Connects relay coils 1 2...

Page 11: ...losed N C 35 K4 Tip Common 10 K4 Ring Common 36 K4 Tip Normally Open N O 11 K4 Ring Normally Open N O 37 K4 Tip Normally Closed N C 12 K4 Ring Normally Closed N C 38 K5 Tip Common 13 K5 Ring Common 39...

Page 12: ...Output 2 47 2 2 Output RECEIVE 2 Input 2 45 2 3 Input Output DISABLE 2 Input Output 10 48 2 4 Output FAIL 2 Input 10 15 3 1 Input Output VOTE 3 Input Output 3 16 3 2 Output RECEIVE 3 Input 3 14 3 3 I...

Page 13: ...35 6 2 Output RECEIVE 6 Input 6 10 5 2 Output RECEIVE 5 Input 5 36 6 4 Output FAIL 6 Input 14 11 5 4 Output FAIL 5 Input 13 37 12 38 13 39 4 3 Input Output DISABLE 4 Input Output 12 14 3 3 Input Outp...

Page 14: ...PWR ACT ERR RESET DC IN OPTION IN OUT NETWORK PRODUCTS INC MODULE GROUP 1 2 3 4 ON PWR ACT ERR RESET DC IN OPTION IN OUT NETWORK PRODUCTS INC MODULE GROUP 1 2 3 4 ON PWR ACT ERR RESET DC IN OPTION IN...

Page 15: ...MCN RYB 8 Relay Board Manual CTI Products Inc CA 80274 100 R VELCRO STRAP CIB OR IOB MODULE CABLE TIE HOLE AMP Figure 4 Relay Mounting Panel Side View 13 68 11206 115...

Page 16: ...or lamp service will not be suitable for low level operation Relay Coil Load Active low 88 mA max 12VDC 110 mA max 15VDC Operate Release Time 4 0 ms max with 12 VDC supply and contact load of 10 mA 6V...

Page 17: ...D8 J2 J2 J2 J2 J2 J2 J2 J2 J2 J2 R9 R10 R11 R12 R13 R14 R15 R16 E9 E10 E11 E12 E13 E14 E15 E16 1 2 3 4 5 26 27 28 29 30 6 7 8 9 10 31 32 33 34 35 11 12 13 14 15 36 37 38 39 40 16 17 18 19 20 41 42 43...

Page 18: ...MCN RYB 8 Relay Board Manual CTI Products Inc 1 6 Board Layout RYB 8 Relay Board CB 11194 100 16 68 11206 115...

Page 19: ...n OK LED for that input is turned off and the red FAIL LED is lit In addition an on board buzzer sounds when either supply input is not present or if any of the input F5 F6 or output F1 F4 fuses are b...

Page 20: ...e GND 2 Ground Reference Table 9 TB1 TB4 Terminal Blocks 2 1 4 2 TB5 TB6 Supply Inputs Signal TB5 TB6 Terminal Description 12Vdc 1 Supply Input Voltage GND 2 Ground Reference Table 10 TB5 TB6 Terminal...

Page 21: ...is used The Relay Power Distribution Board is not used for the Single Power Supply Option POWERSUPPLY POWERSUPPLY F1 F2 F3 F4 HS1 HS2 S1 F5 F6 4 4 CA 80718 100 Figure 5 Mounting of Hot Standby Power...

Page 22: ...MCN RYB 8 Relay Board Manual CTI Products Inc 2 4 Schematic Power Distribution Board 20 68 11206 115...

Page 23: ...MCN RYB 8 Relay Board Manual CTI Products Inc 2 5 Board Layout Power Distribution Board 21 68 11206 115...

Page 24: ...RIDGE BOARD 1 26 25 50 Terminate Unused Ports J1 1 SW1 1 SW2 1 SW3 R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R25 R26 R27 RP7 RP8 RP9 RP10 RP11 RP12 R28 R29 R30 1 SW4 1 SW5 1 SW6 R13 R14 R15 R16 R17 R18 R...

Page 25: ...W5 1 SW6 R13 R14 R15 R16 R17 R18 R19 R20 R21 R22 R23 R24 RP1 RP2 RP3 RP4 RP5 RP6 1 A 1 B 1 C 1 D 2 A 2 B 2 C 2 D 3 A 3 B 3 C 3 D 4 A 4 B 4 D 4 C 5 A 5 B 5 C 5 D 6 A 6 B 6 C 6 D CTI PRODUCTS INC 84 118...