background image

Croydex, Central Way, Andover, 

Hampshire, SP10 5AW, UK

+44 (0) 1264 365881 

+44 (0) 1264 356437

[email protected]

www.croydex.com

CAB 117 R02

1.

x2

MAX

10

kg

MAX

5

kg

EN. 

Please read the information sheet before proceeding. 

WC147169E

HxWxD

70 x 34.5 x 16.5

(cm)

6

mm

Summary of Contents for Houston WC147169E

Page 1: ...over Hampshire SP10 5AW UK 44 0 1264 365881 44 0 1264 356437 info croydex co uk www croydex com CAB 117 R02 1 x2 MAX 10kg MAX 5kg EN Please read the information sheet before proceeding WC147169E HxWxD 70 x 34 5 x 16 5 cm 6mm ...

Page 2: ...ion To retain the best quality finish clean product regularly with a soft damp cloth Do not use abrasive or chemical cleaners as these will damage the product 6 The max load of the cabinet is 10kg when fitted to a solid wall and 5kg when fitted to a cavity wall 7 When drilling into a tiled surface do not use a hammer drill 8 Always use a drill bit that is suitable for the surface that is being dri...

Page 3: ...cation to the Local Authority Building Control Department which has responsibility for ensuring that the work is inspected and tested IMPORTANT WARRANTY INFORMATION In accordance with Statutory Instrument 2004 No 3210 The Building Amendment No 3 Regulations 2004 the installer must give the occupier of the premises in which this product has been installed a certificate to confirm that the requireme...

Page 4: ...Fig 1 This cabinet is rated IP44 and must only be installed with all electrical connections and components in the Outside Zone shown below Ensure that the access to the domestic mains electrical supply is located behind the intended mounting position for the cabinet b x6 a x6 c x4 Ensure that the cabinet is level d x2 e x4 f x2 g x2 h x2 ...

Page 5: ... UK 44 0 1264 365881 44 0 1264 356437 info croydex co uk www croydex com CAB 117 R02 5 3 6 5 b 1 3 7 4 Ensure bracket is fully inserted into the key hole slot Measure Use measurement from previous step 8 4a 4b Ensure that the bracket is level x4 a ...

Page 6: ...Croydex Central Way Andover Hampshire SP10 5AW UK 44 0 1264 365881 44 0 1264 356437 info croydex co uk www croydex com CAB 117 R02 6 7 8 10 9 b 1 3 7 8 x2 ...

Page 7: ...rown conductor is connected to the Live on the domestic electrical mains supply the Neutral Blue conductor is connected to the Neutral on the domestic electrical mains supply and the Earth Yellow Green conductor is connected to the Earth Ground on the domestic electrical mains supply Note connection of the product to the domestic electrical mains supply must only be carried out by a Building Regul...