background image

 

Crestron

 C2N-DB6/8/12 

Decorator Wall Panels 
Operations & Installation Guide

 

Summary of Contents for C2N-DB12

Page 1: ...Crestron C2N DB6 8 12 Decorator Wall Panels Operations Installation Guide...

Page 2: ...by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respectiv...

Page 3: ...Network Wiring 7 Identity Code 8 Installation 12 Programming Software 13 Programming with Crestron AppBuilder or D3 Pro 14 Programming with SIMPL Windows 15 Uploading and Upgrading 20 Communication Se...

Page 4: ......

Page 5: ...buttons on the panel Each of these panels is available in three colors almond black and white A letter at the end of the product name A B or W denotes the color e g C2N DB12B is a black 12 button unit...

Page 6: ...tom engraved keys can be designed and obtained by using the Crestron Engraver software Version 2 1 0 1 or later is available from the Downloads Software Updates section of the Crestron website www cre...

Page 7: ...in 10 57 cm Width 1 79 in 4 55 cm Depth 1 53 in 3 89 cm 4 Weight 2 60 oz 75 g 1 The latest software versions can be obtained from the Downloads Software Updates section of the Crestron website www cr...

Page 8: ...join number information Each wall panel has a button unit with a membrane switch and a male Cresnet network port labeled 24 Y Z G The port provides for operating power and for communications to from...

Page 9: ...55 cm 4 16 in 10 57 cm 1 67 in 4 24 cm 2 70 in 6 86 cm Rubber with buttons removed Front View Cresnet port Back View with buttons installed Side View Membrane Installation View 6 32 x 1 in pan head 2...

Page 10: ...it Once membrane is detached you may be unable to reattach it 3 While holding adjacent buttons in place carefully pull the button s to be replaced from the rubber membrane 4 Carefully press the replac...

Page 11: ...ater after only 20 network devices When calculating the wire gauge for a particular Cresnet run the length of the run and the power factor of each network unit to be connected must be taken into consi...

Page 12: ...o the Cresnet connector and tighten the retaining screw Repeat the procedure for the other three conductors Identity Code Every equipment and user interface within the network requires a unique identi...

Page 13: ...rk device via its serial number which is stored in the device s memory This method does not require that any devices be disconnected from the network NET IDs may be set with the entire Cresnet system...

Page 14: ...f description of the D3 Pro program refer to Programming with Crestron AppBuilder or D3 Pro on page 14 Set Net ID by TSID These procedures are for TSID enabled network devices during the initial confi...

Page 15: ...esnet ID CAUTION This function does not prevent you from setting duplicate IDs Be sure to check current assignments before entering the desired Cresnet ID number 5 Enter the Cresnet ID that the device...

Page 16: ...ial numbers including spaces exactly as they appear on the unit label Alpha characters in serial numbers or TSID numbers may be entered in upper or lower case Installation The following tools hardware...

Page 17: ...omplete project with no special programming required Crestron AppBuilder completes all necessary programming for a base system including all touchpanel screens and the control system program Once Cres...

Page 18: ...ows version 2 04 11 or later with Library Update file 227 Requires SIMPL Cross Compiler version 1 1 Crestron Database version 15 9 8 or later Optional Crestron Engraver version 2 1 0 1 or later Progra...

Page 19: ...er can select configure program test and monitor a Crestron control system SIMPL Windows offers drag and drop functionality in a familiar Windows environment This section explains how to create a SIMP...

Page 20: ...e C2N DB12 from the Wired Keypad folder of the Device Library and drop it in System Views The PRO2 system tree displays the C2N DB12 in Slot 9 with a default NET ID of 71 as shown in the illustration...

Page 21: ...for the C2N DB12 in the program only It does not automatically set the NET ID for the wall panel itself SIMPL Windows automatically changes NET ID values of a device added to a program if a duplicate...

Page 22: ...rogramming Manager NOTE In the symbol the number of press and fbck feedback outputs and inputs respectively correspond to the number of buttons in a given wall panel For example a C2N DB8 has only pre...

Page 23: ...l signals listed in the table are DIGITAL unless noted A digital signal can be high logic level of 1 or low logic level of 0 and have rising edge low to high transitions and falling edge high to low t...

Page 24: ...NOTE The Crestron Viewport is available as a pull down command from SIMPL Windows and VT Pro e Tools Viewport or as a standalone utility The Viewport utility accomplishes multiple system tasks primar...

Page 25: ...procedure in this section provides details for RS 232 communication between the PC and the control system If TCP IP communication is preferred consult the latest version of the Crestron e Control Refe...

Page 26: ...gure after this step From the Viewport menu select Setup Communications settings alternatively press Alt D to open the Port Settings window Setup Communications Settings Command 3 Select RS 232 as the...

Page 27: ...or a 2 Series control system Consult the Operations Guide for the control system being used for exact parameter selection 4 To verify communication select Diagnostics Establish Communications Find Rac...

Page 28: ...that the procedure for Communication Settings that begins on page 20 has been performed 2 As shown after this step select File Transfer Send Program alternatively press Alt P from the Viewport menu ba...

Page 29: ...ge of all the C2N DB12 features it is important that the unit contains the latest firmware available Please check the Crestron website http www crestron com downloads software_updates asp for the late...

Page 30: ...Keypad Firmware Command 3 As shown in the Select Network ID window select the NET ID of the C2N DB12 and then click OK The Open window appears refer to the graphics below and on the next page Select N...

Page 31: ...is loaded automatically 4 Browse to the desired filename a csf file and click Open to begin the transfer The program automatically sends the a file and then the b file Serial Number Assignment These...

Page 32: ...nt Window 3 Enter the device serial number exactly as it appears on the device label 4 Use the drop down list to change the current Cresnet ID NOTE Do not select the Broadcast check box unless your wa...

Page 33: ...on to unit Wall panel Net ID is not correct In Viewport poll the network F4 to verify Net ID Wall panel Net ID is not set to match the Net ID set in the SIMPL Windows program Verify SIMPL Windows prog...

Page 34: ...ia call Crestron Asia at 852 2341 2016 In Latin America call Crestron Latin America at 5255 5093 2160 In Australia and New Zealand call Crestron Pacific at 613 9480 2999 Future Updates As Crestron imp...

Page 35: ...lay components are covered for 90 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers s...

Page 36: ...restron Electronics Inc Operations Installation Guide DOC 6154 15 Volvo Drive Rockleigh NJ 07647 06 03 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notic...

Reviews: