background image

 

 

 

 

 

1 GALLON/ 4 LITER 

WARM MIST HUMIDIFIER

 

 

MODEL# EE- 5200 W / B 

 

 

 

 

 

 
 
 

PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND 

EFFECTIVE USE OF THIS APPLIANCE.

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for EE-5200 B

Page 1: ... 4 LITER WARM MIST HUMIDIFIER MODEL EE 5200 W B PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS APPLIANCE All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...ty Instructions P 3 List of Main Parts Tech Specifications Contents of Packaging P 4 Before First Use P 5 Operation and Use P 5 6 Maintenance P 7 8 Trouble Shooting P 9 Service Center Information P 9 Warranty Information P 10 Warranty Card P 12 All manuals and user guides at all guides com ...

Page 3: ...ces 9 Use only a 110 120VAC outlet ALWAYS plug and unplug unit with dry hands 10 Never operate the unit with a damaged cord or plug 11 Always place the unit on a smooth lint free non metallic waterproof level surface and away from direct sunlight Keep the cord away from heated surfaces and areas where it could be walked on or tripped over Unplug the unit when not in use and whenever you clean or m...

Page 4: ... so that it will not drape over the countertop or tabletop where it can be pulled on by children or tripped over accidentally ELECTRIC POWER If electric circuit is overloaded with other appliances your appliances may not operate properly The appliances should be operated on a separate electrical circuit from other operating appliances POLARIZED PLUG This appliance has a polarized plug one blade is...

Page 5: ...6 Gallon 13 7 Liter Run Time Per Tank Min 7 Hours Humidifying Capacity Up to 250 sq ft 23 m CONTENTS OF PACKAGING NOTE The humidifier is pre assembled and ready to use a Instruction Manual b Humidifier Base c Water Tank d Mist Channel e Mist Chamber f Medicine Cup If any of the above items are missing please contact our service department at 1 888 599 0992 http www crane usa com for replacement Bu...

Page 6: ...om a wall 3 DO NOT place the humidifier on a finished floor or near furniture which can be damaged by moisture or water Place on a water resistant surface 4 DO NOT place Humidifier on top of a towel or a carpeted surface The air vent on the bottom may become blocked and overheat the humidifier OPERATION AND USE 1 Lift the water tank off the humidifier base 2 Turn over the water tank and unscrew th...

Page 7: ... and unplug before removing and refilling the water tank HOW TO USE MEDICINE CUP The medicine cup allows the addition of medications recommended for use with warm mist humidifiers only 1 Remove the medicine cup from top of mist chamber for easier filling 2 BE CAREFUL not to overfill the medicine cup Overfilling may cause medicine to spill into mist chamber Medicine in the mist chamber may affect t...

Page 8: ...e water tank from base and place in sink or tub 3 Carry the humidifier base to the sink and drain any remaining water Wipe clean and dry with a clean cloth 4 Drain water from water tank Wipe clean and dry with a clean cloth Weekly Maintenance Removing Scale NOTE We recommend cleaning the humidifier weekly more often if you have hard water or notice a build up of impurities or detect unpleasant odo...

Page 9: ...any part of the humidifier 2 Save original box for easy storage 3 Leave tank cap partially loosed during storage to prevent tank cap and gasket from sticking together This will prolong the life of the gasket 4 Store humidifier in a cool dry location Cleaning Water Level Sensor To clean the water level senor unscrew see Fig 11 the plastic cap on the pin by pulling it up see Fig 12 Remove the water ...

Page 10: ...t the cap in a cool place The power light is blue but there is little or no mist being emitted Check that there is water in the tank Check for possible lime deposits on the water level senor or the heating element Make sure that nothing blocks the mist output Check that the air vent on bottom of humidifier is not blocked SERVICE CENTER If you have any question in regards to the operation of this a...

Page 11: ... warranty does not apply to normal wear and tear as well as commercial use The warranty is non transferable and applies only to the original purchase and does not extend to subsequent owners of the product Liability under this warranty is limited to repair or replacement In no event shall liability exceed the purchase price paid by the purchaser of the product Under no circumstances shall there be...

Page 12: ...11 All manuals and user guides at all guides com ...

Page 13: ...d include it with a copy of the dated sales receipt In return you will receive your repaired item or a new product at the service center s discretion This Warm Mist Humidifier was tested and meets our stringent quality standards This product is warranted to be free from manufacturing defects in original materials including original parts and workmanship for 1 year with proof of purchase Please pri...

Reviews: