background image

OWNER’S MANUAL 

(English)

TO BE OPERATED BY QUALIFIED PERSONNEL ONLY

CC220E

Refrigerant Charging Scale

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for Compute-A-Charge CC220E

Page 1: ...OWNER S MANUAL English TO BE OPERATED BY QUALIFIED PERSONNEL ONLY CC220E Refrigerant Charging Scale www com information itm com 1 800 561 8187 ...

Page 2: ...re Alerts user when approaching programmed charge amount or overfill limit Auto Power Off APO To conserve battery power and when not in use the scale can be set to turn OFF after any of 5 different time increments see specifications Smart Awake Feature Displays weight at time of Auto Off SCALE LAYOUT KEY FEATURES Durable cast aluminum platform and base Battery level indicator Large 1 2 12 mm numbers...

Page 3: ...anufacturer s Material Safety Data Sheet for further safety information on refrigerants and lubricants WARNING Make certain all safety devices are functioning properly before operating equipment 1 POWER KEY a Press to turn power ON or OFF 2 UNITS KEY Press to select your desired weight unit LB to KG or KG to LB 3 TARE KEY a While in WEIGH mode Press to Tare zero out the scale display b While in HO...

Page 4: ...122 F 10 C to 50 C Overload Protection Mechanical and visual Unit Weight Including Case 5 68 lb 2 6 kg Platform Dimensions 8 75 x 8 75 22 3 x 22 3 cm Calibration National Institute of Standards Technology U S Approvals CE Warranty 2 years SPECIFICATIONS CAUTION To avoid cross contamination of refrigerant and potential leakage to the atmosphere proper hoses and fittings should be used and checked fo...

Page 5: ...ing tracked can be resumed by pressing LCD DISPLAY ABBREVIATIONS A Remove scale from storage case and place on level rigid surface B Install one or two included 9V batteries in back of control C Press power icon to turn scale ON D APO Automatic Power Off 5 minutes default setting you may also select 10 15 30 60 mins or turn APO OFF E DISPLAY RESOLUTION Default is 0 2 Oz 5g Press until desired valu...

Page 6: ...ss 5 TANK ON When t ON Figure R 7 appears place tank on scale press open valves and turn ON Recovery Machine follow manufacturer s instructions to start recovery 6 REMAINING CAPACITY OF TANK Display will show r Figure R 8 indicating recovery in process alongside the remaining tank refrigerant weight capacity until full Display will count backwards from remaining tank capacity indicating decreasing...

Page 7: ...Remember to physically stop recovering refrigerant by closing tank and or manifold valves while activating HOLD 9 NET GAIN At any point during refrigerant recovery pressing and holding will show the net gain indicated by n Figure R 11 The recovery feature will track the net gain during the recovery session except during Hold including even after overfill is reached so that the exact total net gain ...

Page 8: ...y indicator is shown on the LCD as a battery shape with a 3 segment icon 3 segments on bar graph Battery level higher than 66 2 segments on bar graph Battery level between 33 to 66 1 segments on bar graph Battery level between 10 to 33 0 segments on bar graph Battery level between 3 to 10 0 segments on bar graph blinking Battery level below 3 LO CELL displayed on LCD Battery depleted powering down...