background image

OPERATING MANUAL

MODEL NO.

7583-50
7583-52

HAZARDOUS DUTY

PUMP DRIVES

Cole-Parmer Instrument Co.

625 East Bunker Court

Vernon Hills, Illinois U.S.A. 60061-1844

800-MASTERFLEX (627-8373)

(847) 247-2929 (Fax)

www.masterflex.com

e-mail: [email protected]

A-1299-0676

Edition 02

®

and

Untitled-1

2/17/04, 7:27 AM

1

Summary of Contents for Masterflex 7583-50

Page 1: ...DUTY PUMP DRIVES Cole Parmer Instrument Co 625 East Bunker Court Vernon Hills Illinois U S A 60061 1844 800 MASTERFLEX 627 8373 847 247 2929 Fax www masterflex com e mail techinfo coleparmer com A 12...

Page 2: ...Untitled 1 2 17 04 7 27 AM 2...

Page 3: ...ION 1 SETUP AND DRIVE OPERATION 2 Wiring 2 GENERAL INSTRUCTIONS 3 OPERATING INSTRUCTIONS 4 PUMP MOUNTING 5 Add On Head Capacity 6 MAINTENANCE 6 Cleaning 6 Service Parts 6 Lubrication 6 SPECIFICATIONS...

Page 4: ...which may be present WARNING To prevent ignition of hazardous atmospheres this system must not be installed in an area where vapor or gases having an ignition temperature less than 280 C are present C...

Page 5: ...MASTERFLEX L S and MASTERFLEX I P Pump Heads with standard short shafts Ad ditional MASTERFLEX Pump Heads with standard short shafts may be used in tandem The pump speed can be varied from 10 to 430 r...

Page 6: ...plicable local codes The motor must be wired such that the output shaft of the MOTOR rotates in a clockwise direction when facing the motor shaft See the wiring diagram below 2 WIRING DIAGRAM For Mode...

Page 7: ...ting plate opening Then select the appropriate adapter for the pump you wish to drive and slip it into the rubber sleeve and seat it firmly see Figure 2 The pump mounting plate which is mounted to the...

Page 8: ...minimize the starting load it is recommended that the system be at approximately zero speed lever fully CW prior to starting the motor Once the motor has started move the lever to increase speed to t...

Page 9: ...ERFLEX L S and MASTERFLEX I P pumps All of the MASTERFLEX pumps mount in a vertical orientation See Figure 3 Orient the tang of the pump you wish to drive with the drive adapter and install the pump t...

Page 10: ...L S Drive Adapter B 3545 Rubber Coupling Sleeve B 3434 Coupling End 3 8 in Bore Speed Reducer B 3546 Coupling End 5 8 in Bore Motor B 3433 Coupling End 3 4 in Bore Motor European B 3676 Lubrication T...

Page 11: ...nce Painted steel Operating Voltage Frequency 115V AC nominal 57 63 Hz 90 130V AC 4 7 A AC Power Rating 1 4 hp 190W Output Speed Range 10 to 430 rpm Direction of Rotation Clockwise Speed Regulation 10...

Page 12: ...duct misuse or abuse may be invoiced to you The warranty period for this product is noted on the Warranty Card PRODUCT RETURN To limit charges and delays contact the seller or Manufacturer for au thor...