background image

 

 

 

 

CORAL 

Barriera a Microonde 

per protezioni esterne 

Manuale di Installazione 

 

External Microwave Protection 

Barrier  

Installation Handbook 

 

Edizione / Edition 1.0 

 

 
 
 
 
 
 
 
 

 

 
 

 
 

Summary of Contents for CORAL

Page 1: ...CORAL Barriera a Microonde per protezioni esterne Manuale di Installazione External Microwave Protection Barrier Installation Handbook Edizione Edition 1 0...

Page 2: ...ria 14 3 2 COLLEGAMENTO ALL ALIMENTAZIONE PRINCIPALE 16 3 2 1 Collegamento all Alimentazione di Rete 16 3 2 2 Collegamento all Alimentazione di Riserva a Batteria 16 3 3 COLLEGAMENTO ALLA CENTRALE 17...

Page 3: ...t 40 3 2 EQUIPMENT CONNECTION TO THE POWER SUPPLY 42 3 2 1 Connection to the Power Supply 42 3 2 2 Connection of stand by Battery 42 3 3 CONNECTION TO THE CONTROL PANEL 43 3 3 1 Alarm contacts Alarm T...

Page 4: ...l segnale ricevuto viene analizzato in modo assai sofisticato permettendo di raggiungere eccellenti prestazioni nella rilevazione una sostanziale diminuzione dei Falsi Allarmi ed una enorme semplicit...

Page 5: ...GLIATA 800 mm da 710 a 890mm 300mm 2 2 Numero di Tratte Dovendo progettare la protezione con barriere volumetriche di un perimetro chiuso oltre alle normali considerazioni di suddivisione del perimetr...

Page 6: ...atta non deve essere installata in parallelo alla recinzione necessario creare un angolo rispetto ad essa nel caso in cui il fascio sensibile debba essere delimitato lateralmente da due reti metallich...

Page 7: ...zione sia del tipo di antenna impiegata sia della distanza tra Trasmettitore e Ricevitore sia dalla regolazione di sensibilit impostata Le figure seguenti ci forniscono il diametro a met tratta del Fa...

Page 8: ...ntenna impiegata figure 5 6 L Altezza consigliata per installazioni standard di 80 cm circa compatibilmente con le esigenze impiantistiche La misura da considerarsi tra il suolo e il centro dell anten...

Page 9: ...ntro antenna cm Sensibilit Massima F Lunghezza zona morta m Sensibilit minima 0 Figura 6 Lunghezza della zona morta in prossimit degli apparati in funzione dell altezza dal centro dell antenna al suol...

Page 10: ...ETTITORE Mors Simbolo Funzione 1 TMP Contatto Rel di Manomissione NC Tilt Bulb AMP1 2 TMP Contatto Rel di Manomissione NC Tilt Bulb AMP1 3 FLT Contatto Rel di Guasto NC 4 FLT Contatto Rel di Guasto NC...

Page 11: ...scillatore 4V OK 14 15 N C Non Connesso 16 8V Alimentazione interna 8 V CONNETTORE J4 TRASMETTITORE Connettore per microinterruttore apertura Radome Mors Simbolo Funzione 1 GND Collegamento di Massa p...

Page 12: ...cheda CORAL RX MORSETTIERA MS1 RICEVITORE Mors Simbolo Funzione 1 13 8V Positivo per alimentazione circuito 13 8V 2 GND Negativo per alimentazione circuito 3 MPR Positivo per presenza rete 14 6V MORSE...

Page 13: ...NETTORE J4 RICEVITORE Connettore per microinterruttore apertura Radome Tamper Mors Simbolo Funzione 1 GND Collegamento di Massa per Tamper 2 ING Ingresso Tamper 3 GND Collegamento di Massa per Tamper...

Page 14: ...ione del tipo di risposta della barriera all intrusione Default 5 0 Fortissima Diminuzione di Sensibilit per Bersagli Grandi o molto vicini alle teste Tx e Rx Grossi Volatili Gatti che saltano davanti...

Page 15: ...9 24 V or 24V 2 19 V Ingresso Tensione di Alimentazione Alternata 19 24 V or 24V MORSETTIERA MS2 ALIMENTATORE Mors Simbolo Funzione 1 13 8V Positivo per batteria 13 8V limitato a 600 mA 2 GND Negativo...

Page 16: ...uito 13 8V 2 GND Negativo per alimentazione circuito 3 MPR Positivo per presenza rete 14 6V LED DELL ALIMENTATORE N Simbolo Funzione Default 2 D2 Indicazione Presenza Rete ON FUSIBILE DELL ALIMENTATOR...

Page 17: ...rmatore alla rete 230 V deve essere effettuato attraverso un idoneo dispositivo di sezionamento che abbia le seguenti caratteristiche bipolare con distanza minima tra i contatti di 3 mm previsto nell...

Page 18: ...ne e Guasto presentano in stato di Vigilanza contatto chiuso una resistenza di circa 40 Ohm I contatti d allarme sono attivati per i seguenti motivi RELE di ALLARME 1 Preallarme sul Ricevitore Nota 1...

Page 19: ...hermo collegato a terra Per lunghezze del cavo di sincronismo maggiori di 10 metri occorre utilizzare un circuito di ripetizione del sincronismo mod SYNC 01 3 3 3 Connessioni per Stand by Per attivare...

Page 20: ...tivo di batteria filo nero Morsetto 2 di MS2 al negativo di batteria Attenzione l eventuale inversione di polarit della batteria provoca l interruzione del fusibile autoripristinabile Posizionando cor...

Page 21: ...fusibile autoripristinabile Posizionando correttamente i faston il fusibile si ripristiner automaticamente e l apparecchiatura funzioner regolarmente 4 Per ottimizzare l allineamento della barriera ed...

Page 22: ...le della testa trasmittente Tx ed effettuare le operazioni descritte per l orientamento verticale del Ricevitore invece di premere il pulsante S1 del ricevitore oscurare momentaneamente l emissione di...

Page 23: ...occorre regolare questo commutatore a valori maggiori cio 8 9 A B C D E F volendo diminuire la sensibilit occorre regolare questo commutatore a valori minori cio 6 5 4 3 2 1 0 Il cambio di sensibilit...

Page 24: ...possono essere provocate per esempio dal progressivo accumularsi di uno strato di neve lungo la tratta oppure potrebbero essere prodotte dolosamente per cercare di superare la protezione La sensibili...

Page 25: ...canale capitolo 4 1 2 punto j Teste disallineate Eseguire il puntamento come descritto nel capitolo 4 1 2 punti a b c d e f g h i Ostacoli nel campo protetto Rimuovere gli ostacoli Segnale trasmesso...

Page 26: ...ilanza mA 65 Corrente d alimentazione RX in vigilanza mA 60 Corrente d alimentazione RX in allarme mA 54 Alloggiamento per batteria 12Vn 2Ah Contatto allarme intrusione RX 100mA NC Contatto manomissio...

Page 27: ...in caso di risultato positivo 11 Attivazione sul ricevitore di tre uscite a rel statico per allarme manomissione e guasto e sul trasmettitore di due uscite a rel statico per manomissione e guasto 12...

Page 28: ...hing which is moving between the Transmitter TX and the Receiver RX CORAL analyze the received signal and processed in order to obtain the maximum performance therefore less false alarms rate and more...

Page 29: ...vailable Optional the CORAL SP which is specifically designed to be used to install CORAL If you prefer to use another pole it has to have the characteristics showed in the following picture 300mm 630...

Page 30: ...stall the system Therefore remember that it s always preferable to install a even number of section This because in a close perimeter which is made of an odd number of sections it s present one corner...

Page 31: ...hen 5 mt when there s a metallic fences behind the barrier s head it can be a problem due to the fact that it could generate some false alarm rates Trees hedges bushes in general need very great atten...

Page 32: ...based on the length of the section in case of maximum and minimum sensitivity see next picture 1 2 3 4 5 6 7 8 9 10 10 20 30 40 50 60 70 80 90 100 Half range sensitive zone dimension m Maximum sensit...

Page 33: ...book page 32 of 51 CORAL 2 4 6 8 10 12 14 16 18 20 20 40 60 80 100 120 140 160 180 200 220 Maximum sensitivity F Half range sensitive zone diameter m Range m Minimum sensitivity 0 Figure 4 Half range...

Page 34: ...re of the equipment With medium sensitivity setting the suggested crossing overlap is 5 m for the 80 120 200 m versions and 3 5 m for the 50 m version 20 30 10 40 50 60 70 80 90 100 20 30 10 40 50 60...

Page 35: ...CIAS Elettronica S r l Ed 1 0 Installation Handbook page 34 of 51 CORAL 5 M 80 85 cm Dead Zone Dead Zone...

Page 36: ...unctions present on the CORAL Transmitter TRANSMITTER TERMINAL BLOCK MS1 Term Symbol Function 1 13 8V Positive circuit alimentation 13 8V 2 GND Negative circuit alimentation 3 MPR Positive per presenz...

Page 37: ...5 V 13 OSC Measure of the Oscillator functioning 4 V OK 14 15 N C Not used 16 8 V Internal Power supply 8 V CONNECTOR J4 TRANSMITTER Term Symbol Function 1 GND Ground connection for Tamper 2 ING Tamp...

Page 38: ...ows the connector pin functions present on CORALReceiver board RECEIVER TERMINAL BLOCK MS1 Tem Symbol Function 1 13 8V Positive circuit Power supply 13 8 V 2 GND Negative for the circuit power supply...

Page 39: ...ector for micro switch of Tamper Term Symbol Function 1 GND Ground connection for Tamper 2 ING Input for Tamper 3 GND Ground connection for Tamper RECEIVER JUMPERS Term Symbol Function Default 1 Jp1 E...

Page 40: ...big targets or very near to the heads Tx and Rx targets Big birds cats that can jump near the heads ect 1 High Decrease of Sensitivity For big targets or very near to the heads Tx e Rx 2 Medium Decrea...

Page 41: ...l Function 1 19 V Alternate Alimentation Input 19 24 V or 24V 2 19 V Alternate Alimentation Input 19 24 V or 24V TERMINAL BLOCK MS2 POWER SUPPLY Term Symbol Function 1 13 8V Positive for battery 13 8V...

Page 42: ...Term Symbol Function 1 13 8V Positive for Power supply circuit 13 8V 2 GND Negative for Power supply circuit 3 MPR Positive for main presence 14 6V LED POWER SUPPLY N Symbol Function Default 2 D2 Mai...

Page 43: ...mer connection to the main 230 V must be carried out through one circuit breaker having the following characteristics bipolar with minimum distance between contacts equal to 3 mm provided in the fix p...

Page 44: ...these contact is about 40 ohm The connections to control panel must be made by means of shielded cables The relays are activated for the following reasons ALARM RELAYS 1 Pre alarm on receiver Remark1...

Page 45: ...n circuit mod SYNC 01 3 3 3 Stand by connection For the Stand by function activation it is necessary connect to ground the terminal 5 STBY of MS2 terminal block for the receiver circuit and connect to...

Page 46: ...the battery and remember to respect the polarity that means red wire Terminal 1 of MS2 to the positive of the battery and black wire Terminal 2 MS2 to the negative of the battery Attention The batter...

Page 47: ...hat means red wire Terminal 1 of MS2 to the positive of the battery and black wire Terminal 2 of MS2 to the negative of the battery Attention The battery connected in the wrong way will cause the inte...

Page 48: ...owly the head and find the maximum signal see point e i Unlock the vertical movement of the transmitter head Tx and carry out the same operations than the receiver and darken temporally the radiofrequ...

Page 49: ...rease the sensitivity set SW5 in these position 8 9 A B C D E F If it s necessary decrease the sensitivity set SW5 in these position 6 5 4 3 2 1 0 The change of the beam changes the dimension of the s...

Page 50: ...Parameter Acquirement SW1 in position 2 see point j They determinate if during the normal functioning some variations happen and if they alter the protection of the barrier This phenomenon can be caus...

Page 51: ...ield is free from obstacles and free from objects and or person moving Barrier not properly aligned Re do the alignment procedure as described in points a b c d e f g h i of charter 4 1 2 Alarm Led OF...

Page 52: ...lance mA 140 Current absorption RX in alarm mA 130 Current absorption TX in surveillance mA 65 Current absorption RX in surveillance mA 60 Current absorption RX in alarm mA 54 Housing for battery 12Vn...

Page 53: ...storical inhibition living always active the alarm status generation 10 Availability Test input control to procure on receiver the alarm relay activation in case of positive result 11 Activation Three...

Page 54: ...SCOLLEGATA SUPPLY VOLTAGE MEASURED BETWEEN PINS 1 2 OF MS1 WITH BATTERY DISCONNECTED 13 8 VDC 10 2 TENSIONE DI ALIMENTAZIONE INTERNA MISURATA TRA IL PIN 16 DI J3 E GND INSIDE SUPPLY VOLTAGE MEASURED...

Page 55: ...ALIMENTAZIONE MISURATA TRA I PIN 1 2 DI MS1 CON BATTERIA SCOLLEGATA SUPPLY VOLTAGE MEASURED BETWEEN PINS 1 2 OF MS1 WITH BATTERY DISCONNECTED 13 8 VDC 10 2 TENSIONE DI ALIMENTAZIONE INTERNA MISURATA T...

Page 56: ...NOTE...

Page 57: ...other relevant provisions of Directive 1999 5 EC Art 3 1a 3 1b 3 2 Copyright CIAS Elettronica S r l Stampato in Italia Printed in Italy CIAS Elettronica S r l Direzione Ufficio Amministrativo Ufficio...

Reviews: