Arena Hazer™ 
 

 

 

 
 
 
 
 

 

Snapshot 

OK on Dimmer 

 

Outdoor OK 

 

Sound Activated 

 

DMX512 

Master/Slave 

 

115V/230V Switch 

 

Replaceable Fuse 

User Serviceable 

 

Duty Cycle 

 

 
 
 
 

USER MANUAL 

 

Summary of Contents for Arena Hazer

Page 1: ...L 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com Arena Hazer Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master Slave 115V 230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL ...

Page 2: ... Data Cable 8 Cable Connectors 9 3 Pin to 5 Pin Conversion Chart 9 SETTING UP A DMX SERIAL DATA LINK 9 4 OPERATING INSTRUCTIONS 10 OPERATION 10 Stand Alone Mode with Timer Remote 10 Stand Alone Mode without Timer Remote 10 DMX Mode 10 DMX CHANNEL VALUES 10 SETTING THE STARTING ADDRESS 11 DMX Quick Reference Chart 12 GENERAL TROUBLESHOOTING 13 TECHNICAL SUPPORT 14 5 APPENDIX 14 DMX PRIMER 14 GENERA...

Page 3: ...ions chart A product s listed current rating is its average current draw under normal conditions All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Before applying power check that the source voltage matches the product s requirement Warning Thi...

Page 4: ...n 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Always disconnect from power source before servicing or replacing lamp or fuse and be sure to replace with same lamp source Maximum ambient temperature Ta is 95 F 35 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the ...

Page 5: ...og liquid from the machine Add cleaning solution to tank Plug unit in and begin warm up 2 Run the unit in a well ventilated area until the tank is almost empty Do not allow the pump to run dry 3 Replace nozzle 4 Cleaning is now complete Refill with fog liquid Run the machine briefly to clear any cleaning solution from the pump and heater 5 Do not operate the fog machine without liquid at any time ...

Page 6: ...Adjustable blower speed via DMX or control panel on rear with variable angles Additional Features Road case included with easy refill system True continuous output 600 watt heater Output 20 000cfm haze 1 4 quart tank capacity Wired multi function remote included Water based hazer DMX Channel Summary CHANNEL FUNCTION 1 Haze 2 Fan 3 Blower Product Overview Squirrel cage blower Fluid level indicator ...

Page 7: ...DMX Address DMX Out Power Switch Fan DMX In IEC Power Connector Rear of hazer Inside flight case DMX In Dipswitches Power Switch and Fan Speed Control Knob Hazer Power Cable Fuse IEC Power Connector Arena Hazer User Manual 7 2007 05 29 16 06 ...

Page 8: ...al data link must be daisy chained in one single line To comply with the EIA 485 standard no more than 32 devices should be connected on one data link Connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal Maximum recommended serial data link distance 500 meters 1640 ft Maximum recommended ...

Page 9: ...low contact between the common and the fixture s chassis ground Grounding the common verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each othe RSION CHART Note If you use a controller with a 5 The chart below details a proper cable conversion ONVERSION CHART Con tor Ground Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Do not use D...

Page 10: ...panel by the dipswitches to adjust the blower speed e Mode without Timer Remote de allows a single unit to run without the timer remote 1 Set the DMX address of the hazer to 6XX where and the second X represents the desired fan speed 0 is off and 9 is high 2 Adjust the speed of the blower by turning the knob on the inner control panel by the dipswitches Note The blower has a DMX in but does not ha...

Page 11: ...he largest value switch that is less than the start address Turn this switch on 2 Subtract the value of the switch you just turned on from the starting address number 3 Determine the largest value switch that is less than the remainder from the previous subtraction Turn this switch on 4 Subtract the value of the switch you just turned on from the remainder of the previous subtraction 5 Repeat step...

Page 12: ...364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 14...

Page 13: ...e at end of its life 9 L l t m o e l i ight wi l no co e n after power failur Some discharge amps requ re a cooling off period befo aga re t in w he e ait 5 lectro to 1 nics i 0 min n the utes b fixture efore can powe kick start it ring up 9 Loss of signa d e 9 l Use Inst onl all te y DM rmi X ca nator bles Note Keep DMX cables separate from pow r cables or black lights 9 9 9 Moves slow Check 220 ...

Page 14: ...rie pliant cables DMX 10 33 DMX 4 5 15 and DMX 5 Press 4 n Service www chauvetlighting com DMX Primer T are 512 channels in a DMX 512 connection Chan signe an er A must ssign a starting address on the fixture that indicates the first channel reserved are many different types of DMX controllable fixtures nnels required Choosing a start address should be planned in advance Chann overlap If they do t...

Page 15: ...uch as missing component part damage not related to shipping and concealed damage must be made within seven 7 days of receiving merchandise To maintain optimum perfo and environment are contributing factors in dete up be cleaned at least twice a month Dust build overheating This can lead to reduced la fixture before conducting maintenance Unplug fixture collected on e so The cleaning of internal a...

Page 16: ...on 752W 6 44A at 120V Ma Inrush power 752W 6 44A at 120V Power factor 0 97 PERFORMANCE Output THERMAL Maximum ambient temperature 104 F 40 C FUSE Hazer 20mm Glass 7A 250V Slo Internal control panel 20mm Glass 7A 250V Slow CONTROL P Data input Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 2 ORDERING INFORMATION Arena...